Smart pump user interface evaluation

被引:0
|
作者
Viviani, C. A. B. [1 ]
Calil, S. J. [1 ]
机构
[1] State Univ Campinas UNICAMP, FEEC, DEB, Campinas, SP, Brazil
关键词
Interface; medical devices; smart pumps; compatibility;
D O I
10.1007/978-3-319-19387-8_367
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
there are at least 73 infusion pump manufacturers registered with the Food and Drugs Administration (FDA). Many events reported by the FDA occurred due to usability problems of medical devices, which are often related to lack of consistency in the interface. This may induce the user to error and consequently the occurrence of problems during the device operation. To minimize such events, it is required a careful evaluation of the interface device and also its standardization. Infusion pumps are always present in ECRI's reports as one of the devices that have the highest probability of risk to the patient. The objective of this study is to verify the interfaces consistency of four infusion pumps developed by leading manufacturer in world market. The methodology is structured in two stages. The first stage referred to the development of an appropriate set of criteria for comparing the interfaces of the smart infusion pumps. In the second stage, it was applied the developed criteria to the interfaces using the four pumps as a practical study Evaluation results showed that there is no standardization for designing medical devices of the same type and cathegory; in this case study the smart pumps. It also suggested that each manufacturer designs a device considering only aesthetic issues and does not maintain any consistency with other manufacturers and even with other models or different version devices. This preliminary study provides us with evidence that this lack of consistency between the interfaces of these devices can lead to usability problems, and can lead untrained users to error. Additional studies are needed to further investigation and thereby demonstrate qualitatively results.
引用
收藏
页码:1512 / 1514
页数:3
相关论文
共 50 条
  • [1] Implementation and evaluation of an on-device customizable user interface for smart devices
    Okada, Eigo
    Sun, Xiaojin
    Sato, Mitsuko
    Nakamoto, Yukikazu
    2008 IEEE 8TH INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 231 - 236
  • [2] User Satisfaction On Smart Phone Interface Design; Information Quality Evaluation
    Zamzami, Ikhlas
    Mahmud, Murni
    2012 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER SCIENCE APPLICATIONS AND TECHNOLOGIES (ACSAT), 2012, : 78 - 82
  • [3] A smart interface for this vacuum pump series
    Ondrey, Gerald
    Chemical Engineering (United States), 2023, (5 May):
  • [4] User interface for a PCS smart phone
    Narayanaswamy, S
    Hu, JY
    Kashi, R
    IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS, PROCEEDINGS VOL 1, 1999, : 777 - 781
  • [5] User interface for a PCS smart phone
    Narayanaswamy, Shankar
    Hu, Jianying
    Kashi, Ramanujan
    International Conference on Multimedia Computing and Systems -Proceedings, 1 : 777 - 781
  • [6] Towards smart user interface design
    Cerny, T. (tomas.cerny@fel.cvut.cz), 2012, IEEE Computer Society
  • [7] Design and evaluation of smart home user interface: effects of age, tasks and intelligence level
    Zhang, Bin
    Rau, Pei-Luen Patrick
    Salvendy, Gavriel
    BEHAVIOUR & INFORMATION TECHNOLOGY, 2009, 28 (03) : 239 - 249
  • [8] Adaptive User Interface for Smart Programming Exercise
    Watanobe, Yutaka
    Rahman, Md. Mostafizer
    Vazhenin, Alexander
    Suzuki, Jun
    IEEE TALE2021: IEEE INTERNATIONAL CONFERENCE ON ENGINEERING, TECHNOLOGY AND EDUCATION, 2021, : 588 - 594
  • [9] User interface design and evaluation
    Wei, June
    Coquereau, Lauren
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2006, 21 (03) : 355 - 359
  • [10] User interface design and evaluation
    Miller, EK
    TECHNICAL COMMUNICATION, 2005, 52 (04) : 488 - 489