Assessment of direct analysis in real time accurate mass spectrometry for the determination of triclosan in complex matrices

被引:8
|
作者
Cobo-Golpe, M. [1 ]
Garcia-Martin, J. [1 ]
Ramil, M. [1 ]
Cela, R. [1 ]
Rodriguez, I. [1 ]
机构
[1] Univ Santiago Compostela, IAQBUS Inst Res Chem & Biol Anal, Dept Analyt Chem Nutr & Food Sci, R Constantino Candeira SN, Santiago De Compostela 15782, Spain
关键词
Ambient ionization; Triclosan; Direct analysis in real time (DART); Accurate mass spectrometry; Environmental samples; Matrix effects; WATER TREATMENT PLANTS; WASTE-WATER; GAS-CHROMATOGRAPHY; PHASE MICROEXTRACTION; METHYL-TRICLOSAN; AQUEOUS SAMPLES; NORTH TEXAS; BIOACCUMULATION; TRICLOCARBAN; PHARMACEUTICALS;
D O I
10.1007/s00216-021-03591-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the applicability of direct analysis in real time coupled to accurate mass spectrometry (DART-MS) to the quantitative determination of triclosan (TCS) in samples with increasing complexity, from personal care products to extracts from sewage, is investigated. In the first term, DART-MS spectra of TCS as free phenol and as derivatized species are characterized; thereafter, the effects of several instrumental variables in the detectability of TCS (i.e., temperature, solvent, and compound holder) are discussed. Under final selected conditions, TCS was determined from its [M-H](-) ions, without need of derivatization, attaining an instrumental limit of quantification of 5 ng mL(-1), with a linear response range up to 1000 ng mL(-1). Complex matrices, such as solid-phase extracts obtained from environmental water samples, moderately inhibited the ionization efficiency of TCS, with signal attenuation percentages in the range of 6 to 57%, depending on the sample type and on the concentration factor provided by the SPE procedure. The accuracy of results obtained by DART-MS was evaluated using liquid chromatography (LC) with MS detection; in both cases, a time-of-flight (TOF) MS instrument was employed for the selective determination of the [M-H](-) ions of TCS (m/z values 286.9439 and 288.9410) using a mass window of 20 ppm. DART-MS did not only provide enough sensitivity to detect the presence of TCS in environmental samples (raw and treated wastewater as well as freeze-dried sludge), but also measured concentrations matched those determined by LC-ESI-TOF-MS, with only slightly higher standard deviations. During analysis of personal care products, containing much higher concentrations of TCS in a less complex matrix, both techniques were equivalent in terms of accuracy and precision.
引用
收藏
页码:6355 / 6364
页数:10
相关论文
共 50 条
  • [41] Differentiating writing inks using direct analysis in real time mass spectrometry
    Jones, RW
    Cody, RB
    McClelland, JF
    JOURNAL OF FORENSIC SCIENCES, 2006, 51 (04) : 915 - 918
  • [42] Applications of direct analysis in real time mass spectrometry to cultural heritage materials
    Armitage, Ruth Ann
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [43] In situ and rapid identification of tea by direct analysis in real time mass spectrometry
    Zhang Jialing
    Zhang Wei
    Zhou Zhigui
    Bai Yu
    Liu Huwei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (07) : 681 - 686
  • [44] Rapid identification of polyamides using direct analysis in real time mass spectrometry
    Abe, Yutaka
    Ackerman, Luke K.
    Mutsuga, Motoh
    Sato, Kyoko
    Begley, Timothy H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
  • [45] Ionization characteristics of amino acids in direct analysis in real time mass spectrometry
    Sekimoto, Kanako
    Sakakura, Motoshi
    Kawamukai, Takatomo
    Hike, Hiroshi
    Shiota, Teruhisa
    Usui, Fumihiko
    Bando, Yasuhiko
    Takayama, Mitsuo
    ANALYST, 2014, 139 (10) : 2589 - 2599
  • [46] Determination of Dicyandiamide in Powdered Milk Using Direct Analysis in Real Time Quadrupole Time-of-Flight Tandem Mass Spectrometry
    Zhang, Liya
    Yong, Wei
    Liu, Jiahui
    Wang, Sai
    Chen, Qilong
    Guo, Tianyang
    Zhang, Jichuan
    Tan, Tianwei
    Su, Haijia
    Dong, Yiyang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (08) : 1414 - 1422
  • [47] New coupling of planar chromatography with direct analysis in real time mass spectrometry
    Morlock, Gertrud
    Ueda, Yoshihisa
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) : 243 - 251
  • [48] Direct analysis of complex mixtures by mass spectrometry
    Cooks, R. Graham
    Jarmusch, Alan K.
    Wleklinski, Michael
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 709 - 718
  • [49] Purification of pharmaceutical preparations using thin-layer chromatography to obtain mass spectra with Direct Analysis in Real Time and accurate mass spectrometry
    Wood, Jessica L.
    Steiner, Robert R.
    DRUG TESTING AND ANALYSIS, 2011, 3 (06) : 345 - 351
  • [50] Capabilities and limitations of direct analysis in real time orbitrap mass spectrometry and tandem mass spectrometry for the analysis of synthetic and natural polymers
    Bridoux, Maxime C.
    Machuron-Mandard, Xavier
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (18) : 2057 - 2070