A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring

被引:4
|
作者
Shen, Qin [1 ]
Li, Jianqing [2 ,3 ]
Cui, Chang [1 ]
Wang, Xingyao [3 ]
Gao, Hongxiang [3 ]
Liu, Chengyu [3 ]
Chen, Minglong [1 ]
机构
[1] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Sch Biomed Engn & Informat, Nanjing 211166, Jiangsu, Peoples R China
[3] Southeast Univ, Sch Instrument Sci & Engn, Nanjing 210096, Jiangsu, Peoples R China
来源
JOURNAL OF BIOMEDICAL RESEARCH | 2021年 / 35卷 / 03期
关键词
wearable ECG device; Holter; real-time; remote ECG monitoring; CARDIAC OUTPATIENT TELEMETRY; SILENT ATRIAL-FIBRILLATION; IPHONE ECG; DIAGNOSIS; ACCURACY; PALPITATIONS; PREVENTION; SYSTEM; DETECT;
D O I
10.7555/JBR.34.20200074
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases. Among them, atrial fibrillation (AF) and malignant ventricular arrhythmias are usually associated with some clinical events. Early diagnosis of arrhythmias, particularly AF and ventricular arrhythmias, is very important for the treatment and prognosis of patients. Holter is a gold standard commonly recommended for noninvasive detection of paroxysmal arrhythmia. However, it has some shortcomings such as fixed detection timings, delayed report and inability of remote real-time detection. To deal with such problems, we designed and applied anew wearable 72-hour triple-lead H3-electrocardiogram (ECG) device with a remote cloud-based ECG platform and an expert-supporting system. In this study, 31 patients were recruited and 24-hour synchronous ECG data by H3-ECG and Holter were recorded. In the H3-ECG group, ECG signals were transmitted using remote real-time modes, and confirmed reports were made by doctors in the remote expert-supporting system, while the traditional modes and detection systems were used in the Holter group. The results showed no significant differences between the two groups in 24-hour total heart rate (HR), averaged HR, maximum HR, minimum HR, premature atrial complexes (PACs) and premature ventricular complexes (PVCs) (P>0.05). The sensitivity and specificity of capture and remote automatic cardiac events detection of PACs, PVCs, and AF by H3-ECG were 93% and 99%, 98% and 99%, 94% and 98%, respectively. Therefore, the long-term limb triple-lead H3-ECG device can be utilized for domiciliary ECG self-monitoring and remote management of patients with common arrhythmia under medical supervision.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [21] Validation of a gyroscope-based wearable device for real-time position monitoring of patients in a hospital
    Lee, Jung Hwan
    Lee, Jae Il
    Kim, Dong Hwan
    Nam, Kyoung Hyup
    Jeon, Tae Jin
    Han, In Ho
    [J]. TECHNOLOGY AND HEALTH CARE, 2021, 29 (04) : 843 - 848
  • [22] REAL-TIME HOLTER AMBULATORY ECG MONITORING - ONE YEAR EXPERIENCE
    FIUZA, M
    PINTO, F
    DIAS, E
    PEDRO, P
    RIBEIRO, F
    CORREIA, J
    DEPADUA, F
    [J]. ELECTROCARDIOLOGY 1988, 1989, 830 : 123 - 128
  • [23] Comparison of Continuous ECG Monitoring by Wearable Patch Device and Conventional Telemonitoring Device
    Choi, Wonsuk
    Kim, Sun-Hwa
    Lee, Wonjae
    Kang, Si-Hyuck
    Yoon, Chang-Hwan
    Youn, Tae-Jin
    Chae, In-Ho
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2020, 35 (44)
  • [24] A real-time intrauterine catheter technique for fetal electrocardiogram monitoring
    Horner, SL
    Holls, WM
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3066 - 3069
  • [25] Wearable Armband Device for Daily Life Electrocardiogram Monitoring
    Lazaro, Jesus
    Reljin, Natasa
    Hossain, Md-Billal
    Noh, Yeonsik
    Laguna, Pablo
    Chon, Ki H.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (12) : 3464 - 3473
  • [26] Real-Time Monitoring and Analysis of Zebrafish Electrocardiogram with Anomaly Detection
    Lenning, Michael
    Fortunato, Joseph
    Le, Tai
    Clark, Isaac
    Sherpa, Ang
    Yi, Soyeon
    Hofsteen, Peter
    Thamilarasu, Geethapriya
    Yang, Jingchun
    Xu, Xiaolei
    Han, Huy-Dung
    Hsiai, Tzung K.
    Cao, Hung
    [J]. SENSORS, 2018, 18 (01)
  • [27] Real-Time Electrocardiogram Monitoring during Treadmill Training in Mice
    Tomsits, Philipp
    Chivukula, Aparna Sharma
    Chataut, Kavi Raj
    Simahendra, Agus
    Weckbach, Ludwig T.
    Brunner, Stefan
    Clauss, Sebastian
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (183):
  • [28] A wireless electrocardiogram system for real-time, continuous cardiovascular monitoring
    Han, Seungju
    Kim, Soyeon
    Lee, Jaekeun
    Kim, Kangil
    Kim, Dohyung
    Lee, Sangmin
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 12 - 13
  • [29] VALIDITY OF REAL-TIME DATA GENERATED BY A WEARABLE MICROTECHNOLOGY DEVICE
    Weaving, Dan
    Whitehead, Sarah
    Till, Kevin
    Jones, Ben
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (10) : 2876 - 2879
  • [30] Prediction of a migraine crisis in real-time using a wearable device
    Gonzalez-Martinez, A.
    Galvez-Goicurria, J.
    Pagan, J.
    Quintas, S.
    Vieira, A.
    Ramiro, C. A.
    Sobrado, M.
    Ayala, J. L.
    Vivancos, J.
    Gago-Veiga, A. B.
    [J]. JOURNAL OF HEADACHE AND PAIN, 2022, 23 (SUPPL 1):