Operative and Perioperative Durations in O-Arm vs C-Arm Fluoroscopy for Lumbar Instrumentation

被引:13
|
作者
Knafo, Steven [1 ,2 ]
Mireau, Etienne [1 ,2 ]
Bennis, Saad [1 ,2 ]
Baussart, Bertrand [1 ,2 ]
Aldea, Sorin [1 ,2 ]
Gaillard, Stephan [1 ,2 ]
机构
[1] Foch Hosp, Dept Neurosurg, Suresnes, France
[2] Univ Paris Saclay, UVSQ, Versailles, France
关键词
Accuracy; C-arm; Duration; Instrumentation; O-arm; Spine; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; IMAGING-SYSTEM; NAVIGATION; ACCURACY; SURGERY; FUSION; TRIAL; RATES;
D O I
10.1093/ons/opx142
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Intraoperative 3-dimensional fluoroscopy (eg, O-arm) has been shown to improve accuracy of pedicle screw placement over 2-dimensional fluoroscopy (C-arm), but its effect on surgery duration remains unclear. OBJECTIVE: To compare the durations of operative and perioperative times between O-arm and C-arm procedures for degenerative lumbar disorders. METHODS: We analyzed 198 patients representing 987 pedicle screws treated in a single center by 4 different surgeons between 2013 and 2015. Accuracy of pedicle screw placement was assessed using the Laine classification on postoperative CT scans. Operative and perioperative durations were prospectively reported on the procedure sheet by anesthesiologists. RESULTS: As expected, placement of pedicle screws using O-arm navigation was overall more accurate compared to C-arm fluoroscopy (strictly intrapedicular screws: 549/663 = 82.8% vs 239/324 = 73.8%, P = .008). This benefit did not depend on surgeon individual performance (P = .17). Average operative duration per instrumented level was significantly shorter in the O-arm group (57.3 min vs 66.1 min, P = .02) but also depended on the surgeon, indication, and interbody fusion. However, only surgeon individual performance remained significantly associated with surgery duration in multivariate analysis (P < .001). Similarly, the only factor that remained significantly associated with longer perioperative durations in multivariate analysis was the indication of surgery (P < .001). CONCLUSION: This study shows that O-arm navigation does not independently decrease operative duration, nor increases perioperative time, while improving accuracy of pedicle screw placement.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [21] O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center
    Verma, S. K.
    Singh, P. K.
    Agrawal, D.
    Sinha, S.
    Gupta, D.
    Satyarthee, G. D.
    Sharma, B. S.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2016, 30 (06) : 658 - 661
  • [22] Interventional Procedure under CT-fluoroscopy Combined with C-arm: Application in Lumbar Discography
    Kim, H.
    Lee, S.
    Chung, D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [23] Letter to the Editor Regarding "Comparison of Radiation Exposure Between O-Arm Navigated and C-Arm Guided Screw Placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion"
    Crea, Antonio
    [J]. WORLD NEUROSURGERY, 2021, 150 : 216 - 217
  • [24] Seed segmentation in C-arm fluoroscopy for brachytherapy implant reconstruction
    Vikal, S.
    Jain, A.
    Deguet, A.
    Song, D.
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229
  • [25] Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy
    Park, Young Uk
    Lee, Jong Wha
    Chung, Jun Young
    Choi, Wan-Sun
    Kim, Taehun
    Seo, Young Wook
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1248 - 1254
  • [26] Radiation exposure to the hands from mini C-arm fluoroscopy
    Singer, G
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 795 - 797
  • [27] Cervical spine imaging using standard C-arm fluoroscopy
    Giordano, Brian D.
    Baumhauer, Judith F.
    Morgan, Thomas L.
    Rechtine, Glenn R.
    [J]. SPINE, 2008, 33 (18) : 1970 - 1976
  • [28] Survey of terminology used for the intraoperative direction of C-arm fluoroscopy
    Pally, Elliott
    Kreder, Hans J.
    [J]. CANADIAN JOURNAL OF SURGERY, 2013, 56 (02) : 109 - 112
  • [29] Hardware accelerated C-arm CT and fluoroscopy: A pilot study
    Riabkov, Dmitri
    Brown, Todd
    Cheryauka, Arvi
    Tokhtuev, Alexander
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [30] C-arm fluoroscopy for the removal of an intraorbital foreign body in a cat
    Kim, Se Eun
    Park, Young Woo
    Ahn, Jae Sang
    Son, Won Gyun
    Jeong, Manbok
    Yoon, Junghee
    Seo, Kangmoon
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2011, 13 (02) : 112 - 115