Safety, feasibility, and diagnostic accuracy of accelerated high-dose dipyridamole stress echocardiography

被引:40
|
作者
Dal Porto, R
Faletra, F
Picano, E
Pirelli, S
Moreo, A
Varga, A
机构
[1] CNR, Inst Clin Physiol, I-56123 Pisa, Italy
[2] Niguarda Hosp, Milan, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2001年 / 87卷 / 05期
关键词
D O I
10.1016/S0002-9149(00)01424-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Protocols for dipyridamole stress testing have evolved in the last 16 years in the neverending quest of optimal diagnostic accuracy and user friendliness. Higher dipyridamole dose in a shorter infusion time provides higher sensitivity, but concern over safety is still controversial. An accelerated high-dose (0.84 mg/kg in 6 minutes without atropine) dipyridamole stress test was performed on 1,295 patients in 2 echocardiographic laboratories: institute of Clinical Physiology of Pisa and Niguarda Hospital of Milan. During testing, there were no deaths and no patients had ventricular fibrillation. Major adverse reactions occurred in 3 cases (1 every 431 studies): 1 myocardial infarction, 1 brief cardiac asystole, and 1 transient ischemic attack. Overall feasibility was 97%. In 66 patients with normal function at rest who were evaluated off therapy, with coronary angiography performed independently of test results, the accelerated high-dose protocol showed a sensitivity of 85% (confidence interval [CI] 73% to 92%) and a specificity of 93% (CI 83% to 97%) for angiographically assessed coronary artery disease (quantitatively assessed diameter reduction greater than or equal to 50%). Diagnostic accuracy of the accelerated high dose was 89% (CI 79% to 95%). Thus, accelerated high-dose dipyridamole stress echocardiography was reasonably safe and well tolerated. This protocol is especially appealing for its excellent diagnostic accuracy coupled with the short imaging time and no need for drug cocktails. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [41] COMPARISON OF THE HIGH-DOSE DIPYRIDAMOLE-ECHOCARDIOGRAPHY TEST AND EXERCISE TWO-DIMENSIONAL ECHOCARDIOGRAPHY FOR DIAGNOSIS OF CORONARY-ARTERY DISEASE
    PICANO, E
    LATTANZI, F
    MASINI, M
    DISTANTE, A
    LABBATE, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (06): : 539 - 542
  • [42] HIGH-DOSE DIPYRIDAMOLE-ECHOCARDIOGRAPHY TEST IN WOMEN - CORRELATION WITH EXERCISE-ELECTROCARDIOGRAPHY TEST AND CORONARY ARTERIOGRAPHY
    MASINI, M
    PICANO, E
    LATTANZI, F
    DISTANTE, A
    LABBATE, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (03) : 682 - 685
  • [43] COMPARISON OF USEFULNESS OF HIGH-DOSE DIPYRIDAMOLE ECHOCARDIOGRAPHY AND EXERCISE ELECTROCARDIOGRAPHY FOR DETECTION OF ASYMPTOMATIC RESTENOSIS AFTER CORONARY ANGIOPLASTY
    PIRELLI, S
    DANZI, GB
    ALBERTI, A
    MASSA, D
    PICCALO, G
    FALETRA, F
    PICANO, E
    CAMPOLO, L
    DEVITA, C
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (16): : 1335 - 1338
  • [44] ACCELERATED DOBUTAMINE STRESS ECHOCARDIOGRAPHY: FEASIBILITY AND PROGNOSTIC VALUE COMPARED TO STANDARD DOBUTAMINE STRESS ECHOCARDIOGRAPHY
    Mohammed, Akif A.
    Shafiq, Ali
    Bhatti, Sabha
    Bhansali, Hardik
    Garikapati, Kiran
    Ananthasubramaniam, Karthikeyan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1236 - A1236
  • [45] A third generation dobutamine-atropine stress echocardiography protocol: Feasibility, accuracy, and safety.
    Schroder, K
    Beckmann, S
    Dingerkus, H
    Krahwinkel, W
    Nixdorff, U
    Voller, H
    Kursten, B
    CIRCULATION, 1996, 94 (08) : 3972 - 3972
  • [46] Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance imaging
    Theodoros D Karamitsos
    Ntobeko BA Ntusi
    Jane M Francis
    Cameron J Holloway
    Saul G Myerson
    Stefan Neubauer
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [47] SAFETY AND DIAGNOSTIC-ACCURACY OF DIPYRIDAMOLE-THALLIUM IMAGING IN THE ELDERLY
    LAM, JYT
    CHAITMAN, BR
    GLAENZER, M
    BYERS, S
    FITE, J
    SHAH, Y
    GOODGOLD, H
    SAMUELS, L
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (03) : 585 - 589
  • [48] STRESS ECHOCARDIOGRAPHY DEMONSTRATES EXCELLENT FEASIBILITY, SAFETY AND DIAGNOSTIC ACCURACY IN PATIENTS WITH SIGNIFICANT OBESITY: FIRST RESULTS FROM THE STRESS ULTRASONOGRAPHY IN MORBID OBESITY (SUMO) STUDY
    Shah, Benoy
    Pabla, Jatinder S.
    Zacharias, Konstantinos
    Balaji, Gothandaraman
    Ramzy, Ihab
    Alhajiri, Abdalla
    Ahmed, Asrar
    Gurunathan, Sothinathan
    Elghamaz, Ahmed
    Khattar, Rajdeep
    Senior, Roxy
    HEART, 2014, 100 : A85 - A85
  • [49] Factors influencing the diagnostic accuracy of dobutamine stress echocardiography
    Schroder, K
    Agrawal, R
    Voller, H
    Kursten, B
    Dissmann, R
    Schultheiss, HP
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 493 - 498
  • [50] Factors influencing the diagnostic accuracy of dobutamine stress echocardiography
    K. Schröder
    R. Agrawal
    H. Völler
    B. Kürsten
    R. Dissmann
    H.-P. Schultheiss
    The International Journal of Cardiac Imaging, 1997, 13 : 493 - 498