Optimal whole blood dilution protocol for preprocessing samples prior to circulating tumor cell capture by size-based isolation

被引:0
|
作者
Fu, Tianhao [1 ]
Li, Sheng [2 ,3 ,4 ]
Wei, Liang [5 ]
Huang, Shaoyi [5 ]
Xue, Yan [6 ]
Cui, Kai [2 ,3 ,4 ]
机构
[1] Guangxi Med Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Nanning, Peoples R China
[2] Shandong Univ, Shandong Canc Hosp, Cheeloo Coll Med, Dept Hepatobiliary Surg, Jinan, Peoples R China
[3] Shandong First Med Univ, Jinan, Peoples R China
[4] Shandong Acad Med Sci, Jinan, Peoples R China
[5] Wuhan YZY Med Sci & Technol Co Ltd, Wuhan, Peoples R China
[6] Jinan Childrens Hosp, Jinan, Peoples R China
关键词
blood dilution; circulating tumor cell; circulating tumor microemboli; size-based isolation;
D O I
10.1002/jcla.24524
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background This study compared whole blood dilution versus density gradient centrifugation for pre-processing blood samples prior to circulating tumor cell (CTC) capture on the efficiency of CTC separation by size-based isolation. Materials and methods Whole blood from a healthy volunteer spiked with SKBR3 cells was used to optimize the whole blood dilution protocol for sample volume, dilution ratio, and paraformaldehyde (PFA) concentration. Whole blood from healthy volunteers spiked with SKBR3, A549, or PC3 cells, and whole blood from patients with advanced gastric, esophageal, or liver cancer, was used to compare pre-processing by the optimal whole blood dilution protocol with density-gradient centrifugation. All statistical evaluations were performed using Student t test of the Statistical Package for Social Sciences (SPSS version 17.0). Results In blood samples from healthy volunteers, spiked SKBR3 cell recovery rates were highest in 5 ml of whole blood, diluted with 2.5 ml buffer, and fixed with 0.2% PFA, and spiked SKBR3, A549, and PC3 cell recovery rates from 5 ml whole blood were significantly greater when using the optimized whole blood dilution protocol (87.67% +/- 1.76%, 79.50% +/- 0.50% and 71.83% +/- 1.04%, respectively) compared to density-gradient centrifugation (46.83 +/- 1.76%, 37.00 +/- 1.50% and 41.00 +/- 1.50%, respectively).
引用
收藏
页数:6
相关论文
共 43 条
  • [21] Micro-cavity array system for size-based enrichment of circulating tumor cells and circulating cancer associated fibroblasts from blood of patients with breast cancer
    Parajuli, R.
    Ly, R.
    Ziogas, A.
    Eapen, A.
    Lane, K.
    Chen, J.
    Lin, E.
    Mehta, R.
    Tsai, A.
    CANCER RESEARCH, 2019, 79 (04)
  • [22] Multifaceted modifications for a cell size-based circulating tumor cell scope technique hold the prospect for large-scale application in general populations
    Zhang, Leisheng
    Zou, Linglin
    Ma, Yue
    Feng, Chunjing
    Zhan, Rucai
    Yang, Hongju
    Song, Baoquan
    Han, Zhongchao
    CELL BIOLOGY INTERNATIONAL, 2021, 45 (02) : 345 - 357
  • [23] Single-Cell Isolation of Circulating Tumor Cells from Whole Blood by Lateral Magnetophoretic Microseparation and Microfluidic Dispensing
    Kim, Jinho
    Cho, Hyungseok
    Han, Song-I
    Han, Ki-Ho
    ANALYTICAL CHEMISTRY, 2016, 88 (09) : 4857 - 4863
  • [24] Fast and efficient microfluidic cell filter for isolation of circulating tumor cells from unprocessed whole blood of colorectal cancer patients
    Ribeiro-Samy, Silvina
    Oliveira, Marta I.
    Pereira-Veiga, Thais
    Muinelo-Romay, Laura
    Carvalho, Sandra
    Gaspar, Joao
    Freitas, Paulo P.
    Lopez-Lopez, Rafael
    Costa, Clotilde
    Dieguez, Lorena
    SCIENTIFIC REPORTS, 2019, 9
  • [25] Fast and efficient microfluidic cell filter for isolation of circulating tumor cells from unprocessed whole blood of colorectal cancer patients
    Silvina Ribeiro-Samy
    Marta I. Oliveira
    Thais Pereira-Veiga
    Laura Muinelo-Romay
    Sandra Carvalho
    João Gaspar
    Paulo P. Freitas
    Rafael López-López
    Clotilde Costa
    Lorena Diéguez
    Scientific Reports, 9
  • [26] Detection of circulating stage III-IV gastric cancer tumor cells based on isolation by size of epithelial tumor: using the circulating tumor cell biopsy technology
    Lu, Rong
    Chen, Qiang
    Liu, Xiaoying
    Shen, Songfei
    Pan, Zhangchi
    Shi, Chunmei
    TRANSLATIONAL CANCER RESEARCH, 2019, 8 (04) : 1342 - 1350
  • [27] Novel size-based design of spiral microfluidic devices with elliptic configurations and trapezoidal cross-section for ultra-fast isolation of circulating tumor cells
    Akbarnataj, Kazem
    Maleki, Sasan
    Rezaeian, Masoud
    Haki, Mohammad
    Shamloo, Amir
    TALANTA, 2023, 254
  • [28] A novel microfluidic system for enrichment of functional circulating tumor cells in cancer patient blood samples by combining cell size and invasiveness
    Wang, Jie
    Meng, Xianmeng
    Yu, Min
    Li, Xin
    Chen, Zhezhou
    Wang, Rui
    Fang, Jin
    BIOSENSORS & BIOELECTRONICS, 2023, 227
  • [29] Isolation and Characterization of Circulating Tumor Cells in Squamous Cell Carcinoma of the Lung Using a Non-EpCAM-Based Capture Method
    Bozzetti, Cecilia
    Quaini, Federico
    Squadrilli, Anna
    Tiseo, Marcello
    Frati, Caterina
    Lagrasta, Costanza
    Azzoni, Cinzia
    Bottarelli, Lorena
    Galetti, Maricla
    Alama, Angela
    Belletti, Silvana
    Gatti, Rita
    Passaro, Antonio
    Gradilone, Angela
    Cavazzoni, Andrea
    Alfieri, Roberta
    Petronini, Pier Giorgio
    Bonelli, Mara
    Falco, Angela
    Carubbi, Cecilia
    Pedrazzi, Giuseppe
    Nizzoli, Rita
    Naldi, Nadia
    Pinto, Carmine
    Ardizzoni, Andrea
    PLOS ONE, 2015, 10 (11):
  • [30] Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor
    Adams, Andre A.
    Okagbare, Paul I.
    Feng, Juan
    Hupert, Matuesz L.
    Patterson, Don
    Goettert, Jost
    McCarley, Robin L.
    Nikitopoulos, Dimitris
    Murphy, Michael C.
    Soper, Steven A.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (27) : 8633 - 8641