Thioglycolic Acid-Functionalized Water-Soluble MoS2-Based Sensor for Toxic Ion Detection

被引:0
|
作者
Majumder, Santanab [1 ]
Sett, Avik [2 ]
Goswami, Dipak Kumar [3 ]
Bhattacharyya, Tarun Kanti [2 ]
机构
[1] Indian Inst Technol Kharagpur, Sch Nanosci & Technol, Kharagpur 721302, W Bengal, India
[2] Indian Inst Technol Kharagpur, Dept Elect & Elect Commun Engn, Kharagpur 721302, W Bengal, India
[3] Indian Inst Technol Kharagpur, Dept Phys, Kharagpur 721302, W Bengal, India
关键词
Mercury sensing; molybdenum disulfide (MoS2); nanoflakes; selectivity; thioglycolic acid (TGA); water dispersion; ROOM-TEMPERATURE; NANOPARTICLES;
D O I
10.1109/TED.2022.3193022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work demonstrates the implementation of thioglycolic acid (TGA) functionalized water-soluble NH2-molybdenum disulfide (MoS2) nanosheets as sensitive layers for toxic heavy metal ion sensing in drinking water. The sensor device was tested for several ions commonly found in drinking water, e.g., As (III), Pd (II), Hg (II), and Cd (II). When the sensor was exposed to individual ions, it showed negligible response toward elements such as As (III), Pd (II), and other commonly present metal ions. However, at 25 ppb, some cross sensitivity was observed between Cd (II) and Hg (II) ions. The mathematical analysis was performed to investigate the cross-sensitive behavior, and a model was put forward. It was evident from the higher attachment factor (N) for Cd concerning Hg (II), derived from the model which supported Cd's higher response when exposed individually (N-Cd = 4 x 10(16) cm(3)/ppb and N-Hg = 1.6 x 10(14) cm(3)/ppb). Furthermore, the band structure and electron concentration were plotted for individual Cd (II) and Hg (II) ions. Compared to Hg (II), Cd (II) efficiently depleted the amine-MoS2 and TGA junction. To better understand selectivity and response, the device was exposed to Cd (II) and Hg (II) ions simultaneously at different concentrations, which looked into the effect of the two interacting ions. A mathematical model was hence established. It was found that the absorption coefficient (K-Hg) was much higher (63 ppb(-1)) than Cd (K-Cd ) (0.38 ppb(-1)). The interaction factor (KHg-Cd), i.e., the absorption coefficient of Cd in the presence of Hg, was calculated as -0.086 ppb(-2), which is lower than KCd-Hg(-0.013 ppb(-2)), which indicated that Hg is more active toward adsorption in competition to the Cd ions. This competitive dominance for Hg (II) adsorption may be attributed to the affinity of thiol groups present in the TGA molecules for Hg (II) over Cd (II) ions. The device was repeatable after testing with five different devices with a standard deviation of Of 0.5322 and stable up to 50 days with +/- 3% response variation. Thus, the proposed sensor may be a suitable candidate for low-cost water quality monitors.
引用
收藏
页码:5193 / 5198
页数:6
相关论文
共 50 条
  • [41] Fast and selective detection of mercury ions in environmental water by paper-based fluorescent sensor using boronic acid functionalized MoS2 quantum dots
    Guo, Xinrong
    Huang, Jianzhi
    Wei, Yubo
    Zeng, Qiang
    Wang, Lishi
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 381
  • [42] CNTs based Water soluble fluorescent sensor for selective detection of Fe3+ ion
    Rajar, Kausar
    Alveroglu, Esra
    MATERIALS RESEARCH BULLETIN, 2020, 124
  • [43] SYNTHESIS OF WATER-SOLUBLE POLYFUNCTIONAL ION-EXCHANGERS BASED ON SODIUM-SALTS OF POLYMETHACRYLOYLBENZENESULFONIC ACID
    YERGOZHIN, YY
    TAUSAROVA, BR
    SHITYBAYEV, SA
    DOKLADY AKADEMII NAUK SSSR, 1991, 320 (03): : 630 - 633
  • [44] Water-Soluble Luminescent Lanthanide Complexes Based on 2-Methacryloyloxyethyleniminodiacetic Acid Copolymers
    Nekrasova, T. N.
    Solovskii, M. V.
    Borisenko, M. S.
    Fisher, A. I.
    Panarin, E. F.
    DOKLADY CHEMISTRY, 2021, 497 (01) : 49 - 53
  • [45] Water-Soluble Luminescent Lanthanide Complexes Based on 2-Methacryloyloxyethyleniminodiacetic Acid Copolymers
    T. N. Nekrasova
    M. V. Solovskii
    M. S. Borisenko
    A. I. Fisher
    E. F. Panarin
    Doklady Chemistry, 2021, 497 : 49 - 53
  • [46] Visual colorimetric sensor for nitroguanidine detection based on hydrogen bonding-induced aggregation of uric acid-functionalized gold nanoparticles
    Can, Kader
    Can, Ziya
    Uzer, Aysem
    Apak, Resat
    TALANTA, 2023, 260
  • [47] Thiolated poly(aspartic acid)-functionalized two-dimensional MoS2, chitosan and bismuth film as a sensor platform for cadmium ion detection
    Cao, Qiang
    Xiao, Yushi
    Huang, Rong
    Liu, Na
    Chi, Hai
    Lin, Cheng-Te
    Huang, Chi-Hsien
    Han, Gang
    Wu, Lidong
    RSC ADVANCES, 2020, 10 (62) : 37989 - 37994
  • [48] A water-soluble fluorescent chemosensor based on Asp functionalized naphthalimide for successive detection Fe3+ and H2PO4-
    Zhang, You-Ming
    Chen, Xiao-Peng
    Liang, Guo-Yan
    Zhong, Kai-Peng
    Yao, Hong
    Wei, Tai-Bao
    Lin, Qi
    CANADIAN JOURNAL OF CHEMISTRY, 2018, 96 (04) : 363 - 370
  • [49] A water-soluble ribosyl-based fluorescent sensor for Hg2+ and Cu2+ ions
    Chen, Yi-Bin
    Wang, Yan-Jhang
    Lin, Yi-Jen
    Hu, Ching-Han
    Chen, Shau-Jiun
    Chir, Jiun-Ly
    Wu, An-Tai
    CARBOHYDRATE RESEARCH, 2010, 345 (07) : 956 - 959
  • [50] Interferometric fiber sensor for lead ion detection based on MoS2 hydrogel coating
    Liu, Shiyu
    Xu, Shujie
    Guan, Junneng
    Qiu, Guitian
    Tong, Zijin
    Yang, Mingyu
    Wei, Zhongchao
    Tan, Chunhua
    Wang, Faqiang
    Meng, Hongyun
    OPTICS COMMUNICATIONS, 2024, 559