Electrical resistance tomography; Activated sludge; Bobble column bioreactors; Gas holdup; Sludge rheology; Mixed Liquor Suspended Solids; COMPUTATIONAL FLUID-DYNAMICS; SUBMERGED MEMBRANE BIOREACTORS; HYDRAULIC RETENTION TIME; WASTE-WATER TREATMENT; MASS-TRANSFER; OXYGEN-TRANSFER; AERATION TANKS; HEAT-TRANSFER; HYDRODYNAMICS; REACTORS;
D O I
10.1016/j.cej.2015.01.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Gas holdup is a determinant factor regarding the efficiency of the activated sludge processes. Despite the numerous studies on the characterization of gas holdup in two or three phase systems, lack of experimental data in systems including actual cells as the solid phase has been emphasized in the literature. This study is a response to the need for an appropriate knowledge on the gas holdup behavior in the real activated sludge systems. The capabilities of electrical resistance tomography in performing local and global measurements in a non-intrusive manner made it possible to examine the influence of MISS concentration and aeration intensity on the overall as well as spatial distribution of gas holdup within the activated sludge bioreactor. In order to cover all activated sludge processes, a wide range of MISS concentration (0.712-15.86 g/L) was employed, and the effect of MISS on rheological characteristics of the corresponding mixed liquor was measured and modeled. The results of the present study revealed an initially increasing followed by decreasing variation of overall gas holdup with increasing MLSS concentration which is reported in this paper for the first time. Radial distribution of gas holdup was also modeled and the variations of central, wall, and cross sectional average gas holdups with axial location, MLSS, and air velocity were specified. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:260 / 269
页数:10
相关论文
共 48 条
  • [31] Application of three-dimensional electrical resistance tomography to characterize gas holdup distribution in laboratory flotation cell
    Kourunen, Jari
    Niitti, Timo
    Heikkinen, Lasse M.
    MINERALS ENGINEERING, 2011, 24 (15) : 1677 - 1686
  • [32] Treatibility of Wastewater Containing 2,4 Dichlorophenol Using Aclimated Activated Sludge Microorganisms in Packed Upflow Column Bioreactor
    Deveci, Ece Ummu
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (05): : 1997 - 2005
  • [33] Gas holdup, gas-liquid interfacial area and mass transfer coefficient in external-loop airlift bubble column containing low density particles
    Miyahara, T
    Hamanaka, H
    Takino, T
    Akagi, Y
    Okada, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1997, 30 (05) : 958 - 961
  • [34] Electrical resistance tomography coupled with differential pressure measurement to determine phase hold-ups in gas-liquid-solid outer loop bubble column
    Jin, Haibo
    Han, Yuhuan
    Yang, Suohe
    He, Guangxiang
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (03) : 228 - 232
  • [35] Electrical Resistance Tomography for Control Applications: Quantitative Study of the Gas-Liquid Distribution inside A Cyclone
    Sattar, Muhammad Awais
    Garcia, Matheus Martinez
    Banasiak, Robert
    Portela, Luis M.
    Babout, Laurent
    SENSORS, 2020, 20 (21) : 1 - 24
  • [36] Investigating the influence of the configuration of the bundle of heat exchanging tubes and column size on the gas holdup distributions in bubble columns via gamma-ray computed tomography
    Sultan, Abbas J.
    Sabri, Laith S.
    Al-Dahhan, Muthanna H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 98 : 68 - 85
  • [37] The parameters measurement of air-water two phase flow using the electrical resistance tomography (ERT) technique in a bubble column
    Jin, Haibo
    Lian, Yicheng
    Yang, Suohe
    He, Guangxiang
    Guo, Zhiwu
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 31 : 55 - 60
  • [38] Application of Electrical Resistance Tomography in an Oscillatory Baffled Column for Gas-Liquid Two-Phase Flow
    Hamzah, A. A.
    Ruzairi, A. R.
    Takriff, M. S.
    Mohamad, E. J.
    Pusppanathan, J.
    Azman, I. N.
    Ghazali, M. S. Mohd
    Sabri, M. Z.
    Mohrab, K. F.
    Ghafar, F.
    Zahari, M. N.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (06): : 119 - 125
  • [39] Dynamic and local gas holdup studies in external loop recirculating airlift reactor with two rolls of fiberglass packing using electrical resistance tomography
    Hamood-ur-Rehman, Mian
    Ein-Mozaffari, Farhad
    Dahman, Yaser
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2013, 88 (05) : 887 - 896
  • [40] Characterization and comparison of a membrane bioreactor and a conventional activated-sludge system in the treatment of wastewater containing high-molecular-weight compounds
    Çiçek, N
    Franco, JP
    Suidan, MT
    Urbain, V
    Manem, J
    WATER ENVIRONMENT RESEARCH, 1999, 71 (01) : 64 - 70