Sampled-data based discrete and fast load frequency control for power systems with wind power

被引:89
|
作者
Xingchen Shang-Guan [1 ,2 ]
He, Yong [1 ,2 ]
Zhang, Chuanke [1 ,2 ]
Jiang, Lin [3 ]
Spencer, Joseph William [3 ]
Wu, Min [1 ,2 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[2] Hubei Key Lab Adv Control & Intelligent Automat C, Wuhan 430074, Peoples R China
[3] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
基金
中国国家自然科学基金;
关键词
Discrete load frequency control; Sampled-data control; Exponential decay rate; Wind power; DELAY-DEPENDENT STABILITY; HIGH PENETRATION; DESIGN;
D O I
10.1016/j.apenergy.2019.114202
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Load frequency control employs communication networks to transmit measurements and control signals. The controller is usually designed in continuous-mode and discretized in implementation with a large sampling period, which may result in a degraded dynamic performance or even cause system instability. On the other hand, high penetration of wind power reduces the inertia of the power system, leading to a faster frequency response and larger frequency deviation after a contingency, and desires a fast load frequency control. Therefore, this paper presents a discrete-mode load frequency control scheme considering a large sampling period of control/measurement signals via sampled-data control, and introduces an exponential decay rate as a new performance index to guide a design of load frequency control scheme with desired faster frequency response. The proposed scheme is evaluated on a one-area power system, a traditional two-area power system with wind power and a deregulated three-area power system with wind power. Using the proposed scheme and the state-of-the-art schemes, the frequency response performance and the tolerance to sampling period of power systems are analyzed. The results demonstrate that the proposed control scheme can ensure the stable operation of the system under a larger sampling period so as to reduce the communication network burden. Also, the results show that the controller designed by a large exponential decay rate can provide a fast frequency response to alleviate the impact of the system's frequency response due to the high penetration of wind power.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Controlling active power of wind farms to participate in load frequency control of power systems
    Zhang, Wei
    Fang, Kailun
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (09) : 2194 - 2203
  • [22] Sampling load frequency control of power systems with doubly-fed wind power
    Li M.
    Zhang Z.
    Lian H.
    Hu S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (02): : 77 - 88
  • [23] STRUCTURE AND SAMPLED-DATA ASPECTS OF AGC FOR POWER-SYSTEMS
    KUSIC, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (01): : 13 - 13
  • [24] Frequency response of sampled-data systems
    Kyoto Univ, Kyoto, Japan
    Automatica, 4 (483-497):
  • [25] Frequency response of sampled-data systems
    Araki, M
    Ito, Y
    Hagiwara, T
    AUTOMATICA, 1996, 32 (04) : 483 - 497
  • [26] Frequency response of sampled-data systems
    Yamamoto, Y
    Khargonekar, PP
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1996, 41 (02) : 166 - 176
  • [27] ON FREQUENCY RESPONSE OF SAMPLED-DATA SYSTEMS
    BROWN, WA
    IEEE TRANSACTIONS ON EDUCATION, 1969, E 12 (02) : 128 - &
  • [28] Sampled-data adaptive nonlinear control of shunt power filters
    Abouelmahjoub Y.
    Giri F.
    Abouloifa A.
    Chaoui F.-Z.
    Kissaoui M.
    Lajouad R.
    Advanced Control for Applications: Engineering and Industrial Systems, 2021, 3 (01):
  • [29] Frequency-Based Load Control in Power Systems
    Zhao, Changhong
    Topcu, Ufuk
    Low, Steven H.
    2012 AMERICAN CONTROL CONFERENCE (ACC), 2012, : 4423 - 4430
  • [30] H∞ Control for Fuzzy Sampled-Data Systems with Discrete and Distributed Delays
    Ishihara, Tomoaki
    Yoneyama, Jun
    2010 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE 2010), 2010,