Heat and mass transfer in falling films technology applied to the generator and the rectifier of an ammonia-water absorption refrigeration cycle

被引:5
|
作者
Narvaez-Romo, Beethoven [1 ,2 ]
Zavaleta-Aguilar, Eli W. [3 ]
Simoes-Moreira, Jose R. [1 ]
机构
[1] Univ Sao Paulo, SISEA Renewable & Alternat Energy Syst Lab, Escola Politecn, Sao Paulo, Brazil
[2] Univ Pontificia Bolivariana, Fac Ingn Mecan, Grp Energia & Termodinam, Circular 1 70-01, Medellin, Colombia
[3] Sao Paulo State Univ Unesp, Campus Itapeva,Rua Geraldo Alckmin 519, Itapeva, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Absorption Refrigeration cycle; Heat and mass transfer; Generation; Rectification; Ammonia-water; Refrigeration; VAPOR ABSORPTION; TRANSFER COEFFICIENTS; SYSTEM; DESIGN; SINGLE; FLOW; OPTIMIZATION; CONCENTRATOR; PERFORMANCE; EVAPORATION;
D O I
10.1016/j.ijrefrig.2021.11.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
Powering ammonia-water absorption refrigeration cycles with solar energy demands an operating temperature above 170 degrees C for the proper generator operation when conventional flooded generator technologies are used. However, the falling film technology operates at a lower temperature due its superior heat and mass transfer performance. Therefore, an experimental investigation focused on the energy balance along with a heat and mass transfer analysis between liquid and vapor ammonia-water mixtures in the generator and the rectifier have been developed. Four experimental sets of runs were carried out for oil temperatures at 111 and 136 degrees C, strong solution mass fraction between 0.37 and 0.47, two rectification temperatures at 34 and 63 degrees C, and a strong solution mass flow rate of 0.016-0.027 kg s(-1). Heat transfer rates for both components were computed by overall energy balances over the components. Moreover, the latent heat and sensible heat rate were calculated. The results indicated that the heat transfer process in the rectifier was lower for the minimum generation temperature. The maximum heat transfer coefficients for the liquid and vapor phase were respectively 5476 and 26 W m(-2) degrees C-1. Analogously, the maximum mass transfer coefficients between the liquid film and vapor phase were 1.27.10(-4 )and 3.25.10(-2) m s(-1).
引用
收藏
页码:276 / 287
页数:12
相关论文
共 50 条
  • [41] Modeling and analysis of an ammonia-water absorption refrigeration system utilizing waste heat with large temperature span
    Lu, Ding
    Xu, Qingyu
    Chen, Gaofei
    Dong, Xueqiang
    Bai, Yin
    Gong, Maoqiong
    Zhao, Yanxing
    Shen, Jun
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 103 : 180 - 190
  • [42] Experimental study of an ammonia-water bubble absorber using a plate heat exchanger for absorption refrigeration machines
    Cerezo, Jesus
    Bourouis, Mahmoud
    Valles, Manel
    Coronas, Alberto
    Best, Roberto
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 1005 - 1011
  • [43] Optimal ammonia water absorption refrigeration cycle with maximum internal heat recovery derived from pinch technology
    Du, S.
    Wang, R. Z.
    Xia, Z. Z.
    [J]. ENERGY, 2014, 68 : 862 - 869
  • [44] Calculation procedure to determine average mass transfer coefficients in packed columns from experimental data for ammonia-water absorption refrigeration systems
    Sieres, Jaime
    Fernandez-Seara, Jose
    [J]. HEAT AND MASS TRANSFER, 2008, 44 (10) : 1229 - 1239
  • [45] A new combined cooling and power system based on ammonia-water absorption refrigeration cycle: Thermodynamic comparison and analysis
    Wang, Jianyong
    Liu, Zhuan
    Wang, Haojin
    Liu, Xiaoqin
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 270
  • [46] AN ENERGETIC AND EXERGOECONOMIC ANALYSIS OF A CCHP SYSTEM WITH MICRO GAS TURBINE, ORGANIC RANKINE CYCLE AND AMMONIA-WATER ABSORPTION REFRIGERATION CYCLE
    Doiphode, Ganesh V.
    Najafi, Hamidreza
    [J]. PROCEEDINGS OF THE ASME 13TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2019, 2019,
  • [47] Performance enhancement of combined cycle power plant using inlet air cooling by exhaust heat operated ammonia-water absorption refrigeration system
    Singh, Omendra Kumar
    [J]. APPLIED ENERGY, 2016, 180 : 867 - 879
  • [48] Synthesis and Optimization of an Ammonia-Water Absorption Refrigeration Cycle Considering Different Types of Heat Exchangers by Application of Mixed-Integer Nonlinear Programming
    Maria Chavez-Islas, Luz
    Heard, Christopher L.
    Grossmann, Ignacio E.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (06) : 2972 - 2990
  • [49] A study of the characteristics of heat transfer for an ammonia-water bubble mode absorber in absorption heat pump systems
    Lee, JC
    Lee, KB
    Chun, BH
    Lee, CH
    Ha, JJ
    Kim, SH
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (04) : 552 - 556
  • [50] A study of the characteristics of heat transfer for an ammonia-water bubble mode absorber in absorption heat pump systems
    Jae-Cheol Lee
    Ki-Bong Lee
    Byung-Hee Chun
    Chan Ho Lee
    Jong Joo Ha
    Sung Hyun Kim
    [J]. Korean Journal of Chemical Engineering, 2002, 19 : 552 - 556