First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation

被引:30
|
作者
Fueting, Anna [1 ,2 ]
Reinsch, Nico [1 ,2 ]
Hoewel, Dennis [1 ,2 ]
Brokkaar, Lenny [2 ,3 ]
Rahe, Gilbert [2 ,4 ]
Neven, Kars [1 ,2 ]
机构
[1] Alfried Krupp Hosp, Dept Electrophysiol, Essen, Germany
[2] Witten Herdecke Univ, Dept Med, Witten, Germany
[3] Alfried Krupp Hosp, Dept Pulmonol, Essen, Germany
[4] Alfried Krupp Hosp, Dept Gastroenterol, Alfried Krupp Str 21, D-45131 Essen, Germany
来源
EUROPACE | 2022年
关键词
Ablation; Atrial fibrillation; Electroporation; Pulsed field ablation; ELECTROPORATION;
D O I
10.1093/europace/euac041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Catheter ablation for atrial fibrillation (AF) using thermal energy can cause collateral damage. Pulsed field ablation (PFA) is a novel non-thermal energy source. Few small clinical studies have been published. We report on the first 'real-world' experience with pulmonary vein isolation (PVI) using PFA for paroxysmal AF (PAF). Methods and results Pre- and post-ablation, phrenic nerve function was assessed. After high-density left atrial (LA) bipolar voltage mapping, all PVs were individually isolated using a 13 Fr steerable sheath and a pentaspline PFA over-the-wire catheter. After ablation, bipolar voltage mapping was repeated to assess lesion formation. In 30 PAF patients (mean 63 years; 53% female), uncomplicated PFA was performed, with all PVs acutely isolated. The median procedure time was 116 min. The median PFA catheter LA dwell time was 29 min. The median fluoroscopy time was 26 min. In one patient with roof-dependent flutter, a roof line was intentionally created. In two patients, unintentional bidirectional mitral isthmus block was created. There was no phrenic nerve or oesophageal damage. In one patient, pericardial drainage after cardiac tamponade was performed. In-hospital stay and 30-day follow-up were uneventful. After 90 days, 97% of patients were in sinus rhythm. Conclusion PVI using PFA for PAF in a 'real-world' setting appears to be safe and feasible in this small patient cohort. Procedure times are homogeneous, and LA dwell time is short. Atrial ablation lines can easily be created. Unintentional ablation of atrial tissue can occur, accurate catheter alignment to the PV ostium and axis should be ensured.
引用
收藏
页码:1084 / 1092
页数:9
相关论文
共 50 条
  • [11] Catheter ablation as first-line treatment for paroxysmal atrial fibrillation
    Pung, Xuanming
    Ching, Chi Keong
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2023, 52 (01) : 6 - 7
  • [12] Pulsed Field Ablation for Atrial Fibrillation
    Schaack, David
    Schmidt, Boris
    Tohoku, Shota
    Bordignon, Stefano
    Urbanek, Lukas
    Ebrahimi, Ramin
    Hirokami, Jun
    Efe, Tolga Han
    Chen, Shaojie
    Chun, K. R. Julian
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2023, 12
  • [13] Pulsed field ablation for atrial fibrillation
    Pasara, Vedran
    Sattin, Tommaso
    De Asmundis, Carlo
    Chierchia, Gian-Battista
    Bala, Gezim
    EXPERT REVIEW OF MEDICAL DEVICES, 2025,
  • [14] Pulsed-field ablation: a breakthrough treatment for atrial fibrillation
    De Potter, Tom
    FUTURE CARDIOLOGY, 2023, 19 (07) : 371 - 373
  • [15] Pulsed Field Ablation of Atrial Fibrillation: An Initial Australian SingleCentre Experience
    Lee, Xiang Wen
    Freeman, Blake M.
    Gunthorpe, Nicole G.
    Eagle, Liam M.
    Webster, Meghan A.
    Betts, John R.
    Denman, Russell A.
    Haqqani, Haris M.
    HEART LUNG AND CIRCULATION, 2024, 33 (01): : 46 - 54
  • [16] Pulsed field ablation of superior vena cava in paroxysmal atrial fibrillation: a case report
    Tao, Yirao
    Zhou, Yang
    Sun, Xuerong
    Liao, Wenkai
    Wang, Yanjiang
    Shi, Liang
    Liu, Xingpeng
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [17] Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
    Verma, Atul E.
    Haines, David V.
    Boersma, Lucas
    Sood, Nitesh
    Natale, Andrea E.
    Marchlinski, Francis
    Calkins, Hugh
    Sanders, Prashanthan L.
    Packer, Douglas
    Kuck, Karl-Heinz
    Hindricks, Gerhard
    Onal, Birce
    Cerkvenik, Jeffrey
    Tada, Hiroshi B.
    DeLurgio, David
    CIRCULATION, 2023, 147 (19) : 1422 - 1432
  • [18] Pulsed Field vs Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation Recurrent Atrial Arrhythmia Burden
    Reddy, Vivek Y.
    Mansour, Moussa
    Calkins, Hugh
    d'Avila, Andre
    Chinitz, Larry
    Woods, Christopher
    Gupta, Sanjaya K.
    Kim, Jamie
    Eldadah, Zayd A.
    Pickett, Robert A.
    Winter, Jeffrey
    Su, Wilber W.
    Waks, Jonathan W.
    Schneider, Christopher W.
    Richards, Elizabeth
    Albrecht, Elizabeth M.
    Sutton, Brad S.
    Gerstenfeld, Edward P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (01) : 61 - 74
  • [19] Early Ablation for Paroxysmal Atrial Fibrillation - Safety First
    Marine, Joseph E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 384 (04): : 374 - 375
  • [20] Impact of Pulsed Field Ablation on Atrial Fibrillation
    Scanavacca, Mauricio
    Pisani, Cristiano
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (10)