First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation

被引:27
|
作者
Fueting, Anna [1 ,2 ]
Reinsch, Nico [1 ,2 ]
Hoewel, Dennis [1 ,2 ]
Brokkaar, Lenny [2 ,3 ]
Rahe, Gilbert [2 ,4 ]
Neven, Kars [1 ,2 ]
机构
[1] Alfried Krupp Hosp, Dept Electrophysiol, Essen, Germany
[2] Witten Herdecke Univ, Dept Med, Witten, Germany
[3] Alfried Krupp Hosp, Dept Pulmonol, Essen, Germany
[4] Alfried Krupp Hosp, Dept Gastroenterol, Alfried Krupp Str 21, D-45131 Essen, Germany
来源
EUROPACE | 2022年
关键词
Ablation; Atrial fibrillation; Electroporation; Pulsed field ablation; ELECTROPORATION;
D O I
10.1093/europace/euac041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Catheter ablation for atrial fibrillation (AF) using thermal energy can cause collateral damage. Pulsed field ablation (PFA) is a novel non-thermal energy source. Few small clinical studies have been published. We report on the first 'real-world' experience with pulmonary vein isolation (PVI) using PFA for paroxysmal AF (PAF). Methods and results Pre- and post-ablation, phrenic nerve function was assessed. After high-density left atrial (LA) bipolar voltage mapping, all PVs were individually isolated using a 13 Fr steerable sheath and a pentaspline PFA over-the-wire catheter. After ablation, bipolar voltage mapping was repeated to assess lesion formation. In 30 PAF patients (mean 63 years; 53% female), uncomplicated PFA was performed, with all PVs acutely isolated. The median procedure time was 116 min. The median PFA catheter LA dwell time was 29 min. The median fluoroscopy time was 26 min. In one patient with roof-dependent flutter, a roof line was intentionally created. In two patients, unintentional bidirectional mitral isthmus block was created. There was no phrenic nerve or oesophageal damage. In one patient, pericardial drainage after cardiac tamponade was performed. In-hospital stay and 30-day follow-up were uneventful. After 90 days, 97% of patients were in sinus rhythm. Conclusion PVI using PFA for PAF in a 'real-world' setting appears to be safe and feasible in this small patient cohort. Procedure times are homogeneous, and LA dwell time is short. Atrial ablation lines can easily be created. Unintentional ablation of atrial tissue can occur, accurate catheter alignment to the PV ostium and axis should be ensured.
引用
收藏
页码:1084 / 1092
页数:9
相关论文
共 50 条
  • [1] Pulsed Field Ablation for Paroxysmal Atrial Fibrillation
    Dhawan, Ravi
    Bikmal, Anirudh
    NEW ENGLAND JOURNAL OF MEDICINE, 2024, 390 (11): : 1054 - 1056
  • [2] Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
    Reddy, Vivek Y.
    Gerstenfeld, Edward P.
    Natale, Andrea
    Whang, William
    Cuoco, Frank A.
    Patel, Chinmay
    Mountantonakis, Stavros E.
    Gibson, Douglas N.
    Harding, John D.
    Ellis, Christopher R.
    Ellenbogen, Kenneth A.
    DeLurgio, David B.
    Osorio, Jose
    Achyutha, Anitha B.
    Schneider, Christopher W.
    Mugglin, Andrew S.
    Albrecht, Elizabeth M.
    Stein, Kenneth M.
    Lehmann, John W.
    Mansour, Moussa
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 389 (18): : 1660 - 1671
  • [3] Epicardial Pulsed Field Ablation for the Treatment of Paroxysmal Atrial Fibrillation During Cardiac Surgery
    Musikantow, Daniel R.
    Reddy, Vivek Y.
    Shaburishvili, Tamaz
    van Zyl, Martin
    O'Brien, Barry
    Coffey, Ken
    Reilly, John
    Asirvatham, Samuel
    de Groot, Joris R.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (09) : 2097 - 2099
  • [4] Initial experience with pulsed field ablation for atrial fibrillation
    Magni, Federico. T. T.
    Mulder, Bart. A. A.
    Groenveld, Hessel. F. F.
    Wiesfeld, Ans C. P.
    Tieleman, Robert. G. G.
    Cox, Moniek. G. G.
    Van Gelder, Isabelle. C. C.
    Smilde, Tom
    Tan, Eng. S. S.
    Rienstra, Michiel
    Blaauw, Yuri
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [5] Cerebral safety after pulsed field ablation for paroxysmal atrial fibrillation
    Reinsch, Nico
    Futing, Anna
    Howel, Dennis
    Bell, John
    Lin, Yali
    Neven, Kars
    HEART RHYTHM, 2022, 19 (11) : 1813 - 1818
  • [6] Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation
    Fueting, Anna
    Reinsch, Nico
    Brokkaar, Lenny
    Hartl, Stefan
    Hoewel, Dennis
    Essling, Anika
    Bell, John
    Rausch, Eva
    Neven, Kars
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (04): : E011547
  • [7] Long-Term Clinical Outcomes of Pulsed Field Ablation in the Treatment of Paroxysmal Atrial Fibrillation
    Musikantow, Daniel R.
    Neuzil, Petr
    Anic, Ante
    Balin, Paul
    Petru, Jan
    Funasako, Moritoshi
    Lisica, Lucija
    Jurisic, Zrinka
    Jais, Pierre
    Reddy, Vivek Y.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (09) : 2001 - 2003
  • [8] Catheter ablation as first-line treatment for paroxysmal atrial fibrillation
    Pung, Xuanming
    Ching, Chi Keong
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2023, 52 (01) : 6 - 7
  • [9] Pulsed Field Ablation for Atrial Fibrillation
    Schaack, David
    Schmidt, Boris
    Tohoku, Shota
    Bordignon, Stefano
    Urbanek, Lukas
    Ebrahimi, Ramin
    Hirokami, Jun
    Efe, Tolga Han
    Chen, Shaojie
    Chun, K. R. Julian
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2023, 12
  • [10] Pulsed-field ablation: a breakthrough treatment for atrial fibrillation
    De Potter, Tom
    FUTURE CARDIOLOGY, 2023, 19 (07) : 371 - 373