Pulse Induction Metal Detector: A Performance Application

被引:2
|
作者
Citak, Hakan [1 ]
机构
[1] Balikesir Univ, Balikesir Vocat High Sch, TR-10145 Balikesir, Turkey
关键词
Detectors; Metals; Soil; Search problems; Magnetic resonance imaging; Shape; Magnetic domains; Detection depth; pulse induction (PI) detector; target-related variables; COIL;
D O I
10.1109/TPS.2020.2996182
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Currently, metal detectors are actively used in the detection of treasures, underground cavities, historical artifacts, lost manhole covers and land mines, as well as firearms and other weapons for public security purposes. Metal detectors are categorized into four groups, based on their operating principles. Beat-frequency oscillation and resonant frequency oscillation are the two early techniques used in metal detectors. Detectors based on the said principles are not preferred due to frequency stability issues. Induction balance (IB) and pulse induction (PI) detectors are more widely used. Recent studies in the literature are mostly focused on the improvement of detection depth, sensitivity, discrimination capability, and soil balancing characteristics of metal detectors. There are many variables affecting detection depth, including detector operating frequency; search coil size; minerals in the soil; and target size, shape, type, and orientation. Among the aforesaid variables, various studies exist in the literature on search coil size and shape. These studies were conducted in vacuum or in nonmetallic media such as sand, not covering parameters such as target size, shape, type, and orientation. A novel PI metal detector was developed in this article, for the purpose of determining the effects of changes in the aforesaid target-related parameters on detection depth in a medium consisting of soil with metallic properties. First, a 3-D mechanical scanner system and the detector& x2019;s microcontroller electronics were manufactured in order to ensure position-controlled and parallel-to-the-surface mobility for the detector& x2019;s search coil. Subsequently, a data collection module was designed to process the detector& x2019;s electronic output data at 24-bit resolution and send data to a computer, as well as a software program to assess and record the data received by the computer. Then, aluminum, brass, iron, and copper objects with known geometric properties were buried in a soil with 28.5& x0025; magnetic particle content and 4.1& x0025; natural humidity, and detector data collected at various positions of the search coil, with the help of the 2-D motion of the mechanical system to which it is connected, were transferred to the digital medium. Such field scans, conducted for each object at a height of 5 cm above surface, enabled detection of the ($x$ , $y$ ) position where the detector produced maximum output. The search coil was then fixed at such ($x$ , $y$ ) positions and the depth of the object to the soil surface was increased in increments of 1 cm along the $z$ -axis. The procedure was repeated until the detector produced zero output, and the data were recorded into the computer. The study discusses the effects of parameters such as object size, shape, and type on maximum detection height for the detector developed.
引用
收藏
页码:2210 / 2223
页数:14
相关论文
共 50 条
  • [41] Investigation of the radiation performance of CCD sensors in a vertex detector application
    Stefanov, KD
    Tsukamoto, T
    Miyamoto, A
    Sugimoto, Y
    Tamura, N
    Takahashi, S
    Abe, K
    Nagamine, T
    Aso, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 182 - 187
  • [42] PULSE-WIDTH DETECTOR
    MADANAGOPAL, KV
    ELECTRONICS WORLD & WIRELESS WORLD, 1993, (1690): : 755 - 755
  • [43] Single-pulse detector
    Anon
    Electronics World, 2001, 107 (1784):
  • [44] Single-pulse detector
    Pillai, SV
    ELECTRONICS WORLD, 2001, 107 (1784): : 631 - 631
  • [45] A mesoscopic terahertz pulse detector
    Orellana, P
    Claro, F
    APPLIED PHYSICS LETTERS, 1999, 75 (11) : 1643 - 1645
  • [46] Study of timing performance of silicon photomultiplier and application for a Cherenkov detector
    Ahmed, G. S. M.
    Buehler, P.
    Marton, J.
    Suzuki, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 393 - 397
  • [47] Application of pulse shape discrimination in Si detector for fission fragment angular distribution measurements
    Nayak, BK
    Mirgule, ET
    Choudhury, RK
    PRAMANA-JOURNAL OF PHYSICS, 2005, 65 (06): : 1053 - 1059
  • [48] Description and application of an acoustic pulse detector to nylon 6 and polypropylene single fiber fracture
    Ellison, MS
    Dai, JR
    TEXTILE RESEARCH JOURNAL, 1996, 66 (05) : 295 - 299
  • [49] Development of a miniature co-axial pulse tube refrigerator for infrared detector application
    Liang, JT
    Hou, YK
    Zhou, Y
    Yang, JH
    Zhu, WX
    INFRARED TECHNOLOGY AND APPLICATIONS XXVI, 2000, 4130 : 52 - 60
  • [50] Application of pulse shape discrimination in Si detector for fission fragment angular distribution measurements
    B. K. Nayak
    E. T. Mirgule
    R. K. Choudhury
    Pramana, 2005, 65 : 1053 - 1059