Laboratory Study of Diversion Using Polymer-Based In-Situ-Gelled Acids

被引:18
|
作者
Gomaa, A. M. [1 ]
Mahmoud, M. A. [1 ]
Nasr-El-Din, N. A. [1 ]
机构
[1] Texas A&M Univ, College Stn, TX 77843 USA
来源
SPE PRODUCTION & OPERATIONS | 2011年 / 26卷 / 03期
关键词
VISCOSITY;
D O I
10.2118/132535-PA
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
In-situ-gelled acids that are based on polymers have been used in the field for several years and were the subject of many laboratory studies. These acids are used in stages to block the treated zone and force the next regular-acid stages to the untreated zones. An extensive literature survey reveals that there are conflicting opinions about using these acids. On one hand, these acids were used in the field, with mixed results. On the other hand, recent laboratory work indicated that these acids can cause damage under certain conditions. The ability of polymer-based in-situ-gelled acids to divert regular acids was studied using a parallel-coreflood setup. The sequence of the injection involved in-situ-gelled acid at 5 wt% hydrochloric acid (HCl) stage followed by regular acid at 15 wt% HCl until acid breakthrough. Experimental results show that flow was initially distributed between the two cores according to the preacid permeability ratio. Permeability grew slightly faster in the higher-permeability core until breakthrough occurred. Therefore, diversion was needed for all acid treatments. At an injection rate of 1 cm(3)/min, in-situ-gelled acid plugged the two cores. For low permeability contrast (1:2), polymer was able to divert the acid, with permeability enhancement in both cores. For high permeability contrast (1:20 up to 1:25), in-situ-gelled acid was able to divert the acid only at an injection rate less than 10 cm(3)/min. However, at higher injection rates, in-situ-gelled acid was not able to build enough pressure to force the regular acid into the low-permeability core. Increasing the injection rate reduced the viscosity of the in-situ-gelled acid. Therefore, acid-injection rate should be determined on the basis of the expected fluid viscosity in the formation. The results obtained can be used to design acid treatments in carbonate reservoirs better.
引用
收藏
页码:278 / 290
页数:13
相关论文
共 50 条
  • [21] Polymer-based redox supercapacitors: A comparative study
    Arbizzani, C
    Mastragostino, M
    Meneghello, L
    ELECTROCHIMICA ACTA, 1996, 41 (01) : 21 - 26
  • [22] Preliminary investigation of polymer-based in situ passive samplers for mercury and methylmercury
    Taylor, Vivien F.
    Buckman, Kate L.
    Burgess, Robert M.
    CHEMOSPHERE, 2019, 234 : 806 - 814
  • [23] Separation of 20 Amino Acids by Polymer-Based Amino HILIC Column
    Ito, Kanna
    LC GC NORTH AMERICA, 2012, : 18 - 18
  • [24] New Applications of Lipid and Polymer-Based Nanoparticles for Nucleic Acids Delivery
    Niculescu, Adelina-Gabriela
    Birca, Alexandra Catalina
    Grumezescu, Alexandru Mihai
    PHARMACEUTICS, 2021, 13 (12)
  • [25] Oral Delivery of Nucleic Acids with Passive and Active Targeting to the Intestinal Tissue Using Polymer-Based Nanocarriers
    Poudel, Sagun
    Napit, Prabhat R.
    Briski, Karen P.
    Mattheolabakis, George
    PHARMACEUTICS, 2021, 13 (07)
  • [26] Study of mechanism retention of nonvolatile alkylphosphonic acids on unmodified selected polymer-based ion exchanger columns
    Mohammadine El Haddad
    Rajâa Boulahjar
    Rachid Slimani
    Marie-Claude Viaud-Massuard
    Saïd El Antri
    Saïd Lazar
    Journal of Analytical Chemistry, 2011, 66 : 586 - 590
  • [27] Delivery of therapeutic miRNA using polymer-based formulation
    Ban, Eunmi
    Kwon, Taek-Hyun
    Kim, Aeri
    DRUG DELIVERY AND TRANSLATIONAL RESEARCH, 2019, 9 (06) : 1043 - 1056
  • [28] Cytometry microchip using polymer-based saltbridge electrodes
    Chun, HG
    Chung, TD
    Kim, HC
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2584 - 2586
  • [29] Study of Mechanism Retention of Nonvolatile Alkylphosphonic Acids on Unmodified Selected Polymer-Based Ion Exchanger Columns
    El Haddad, Mohammadine
    Boulahjar, Rajaa
    Slimani, Rachid
    Viaud-Massuard, Marie-Claude
    El Antri, Said
    Lazar, Said
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (06) : 586 - 590
  • [30] Magnetic field sensor using a polymer-based vibrator
    Wu, Jiang
    Hasebe, Kazuhiko
    Mizuno, Yosuke
    Tabaru, Marie
    Nakamura, Kentaro
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (09)