A comparative assessment of biofiltration and activated sludge diffusion for odour abatement

被引:54
|
作者
Lebrero, Raquel [1 ]
Rodriguez, Elisa [1 ]
Garcia-Encina, Pedro A. [1 ]
Munoz, Raul [1 ]
机构
[1] Univ Valladolid, Dept Chem Engn & Environm Technol, E-47011 Valladolid, Spain
关键词
Activated sludge diffusion system; Biofiltration; Hydrophobicity; Odour treatment; VOC biodegradation; WASTE-WATER TREATMENT; VOLATILE ORGANIC-COMPOUNDS; BIODEGRADATION; BIOFILTERS; PERFORMANCE; AIR;
D O I
10.1016/j.jhazmat.2011.03.090
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The deodorization performance of a biofilter and an activated sludge diffusion (AS) system was comparatively evaluated in terms of removal efficiency (RE) and process stability at empty bed residence times (EBRT) ranging from 94 to 32 s. Both bioreactors were fed with a synthetic odorous emission containing H2S. butanone and toluene at 23.6-43.3, 4.3-6.3 and 0.4-0.6 mg m(-3), respectively. While the outlet H2S concentration was always lower than 1.4 mg m(-3), the REs for butanone and toluene remained higher than 95% in both bioreactors regardless of the EBRT. The continuous supply of wastewater in the AS unit did not affect removal and appeared to be a requirement for efficient pollutant abatement. Despite the narrow carbon source spectrum treated, the AS system maintained a large bacterial diversity over time. Therefore, the results obtained confirmed the potential of AS systems as a robust and efficient biotechnology for odour treatment in WWTPs. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:622 / 630
页数:9
相关论文
共 50 条
  • [31] Assessment of denitrifying bacterial composition in activated sludge
    Srinandan, C. S.
    Shah, Mrinal
    Patel, Bhavita
    Nerurkar, Anuradha S.
    [J]. BIORESOURCE TECHNOLOGY, 2011, 102 (20) : 9481 - 9489
  • [32] Comparative studies on differently arranged activated sludge systems
    Jobbagy, A.
    Grady, C.P.L.
    Morsanyi, G.
    Nyeste, L.
    Simon, J.
    [J]. Water Science and Technology, 1994, 30 (11 pt 11)
  • [33] Comparative Investigation of Parameters for Determining the Dewaterability of Activated Sludge
    Peng, Ge
    Ye, Fenxia
    Li, Ying
    [J]. WATER ENVIRONMENT RESEARCH, 2011, 83 (07) : 667 - 671
  • [34] Optimization of activated sludge recycling and oxidized ammonium recycling as odour control strategies in wastewater treatment plants
    Toledo, M.
    Munoz, R.
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [35] Clarifying the roles of kinetics and diffusion in activated sludge filamentous bulking
    Lou, In Chio
    de los Reyes, Francis L., III
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2008, 101 (02) : 327 - 336
  • [36] Experiences with a large-size WWTP based on activated sludge-biofiltration processes:: 25 months of operation
    Licskó, I
    Szabó, GC
    Melicz, Z
    [J]. WATER SCIENCE AND TECHNOLOGY, 2004, 50 (06) : 285 - 293
  • [37] Simulation and assessment of sludge concentration and rheology in the process of waste activated sludge treatment
    XIA Mingfang WANG Zhiwei WU Zhichao WANG Xinhua ZHOU Zhen LU Jilai State Key Laboratory of Pollution Control and Resource Reuse Nanjing University Nanjing China State Key Laboratory of Pollution Control and Resource Reuse School of Environmental Science and Engineering Tongji University Shanghai China
    [J]. Journal of Environmental Sciences, 2009, 21 (12) : 1639 - 1645
  • [38] Simulation and assessment of sludge concentration and rheology in the process of waste activated sludge treatment
    Xia Mingfang
    Wang Zhiwei
    Wu Zhichao
    Wang Xinhua
    Zhou Zhen
    Lu Jilai
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (12) : 1639 - 1645
  • [40] A comparative adsorption study: 17β-estradiol onto aerobic granular sludge and activated sludge
    Zheng, Xiao-ying
    He, Yu-jie
    Chen, Wei
    Wang, Ming-yang
    Cao, Su-lan
    Ni, Ming
    Chen, Yu
    [J]. ENVIRONMENTAL TECHNOLOGY, 2016, 37 (01) : 136 - 144