Carbon nanotubes paste versus graphite working electrodes in electrochemical analysis

被引:0
|
作者
Prasek, J. [1 ]
Hubalek, J. [1 ]
Adamek, M. [1 ]
Kizek, R. [2 ]
机构
[1] Brno Univ Technol, Dept Microelect, Brno, Czech Republic
[2] Mendel Univ Brno, Dept Chem & Biochem, Brno, Czech Republic
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, the possibility of replacement of mercury drop electrode in heavy metals electrochemical analysis by thick-film sensor with solid electrodes has been presented. Eight types of different pastes containing carbon nanotubes powder and two new types of graphite based pastes have been prepared, deposited and measured using differential pulse voltammetry as a material of the working electrode of the standard thick-film sensor. All the results were plotted out into the plot of calibration curves and compared with measurements of the sensors with different type of graphite working electrodes, classical commercial graphite electrode SESV11 and sensor with gold working electrode.
引用
收藏
页码:1261 / +
页数:3
相关论文
共 50 条
  • [21] Electrochemical study of reduced ilmenite carbon paste electrodes
    [J]. Marinovich, Y, 1600, Chapman & Hall Ltd, London, United Kingdom (25):
  • [22] ELECTROCHEMICAL-BEHAVIOR OF ADRIAMYCIN AT CARBON PASTE ELECTRODES
    BALDWIN, RP
    PACKETT, D
    WOODCOCK, TM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (03) : 540 - 542
  • [23] Electrochemical Determination of Adrenaline Using MXene/Graphite Composite Paste Electrodes
    Shankar, S. Sharath
    Shereema, Rayammarakkar M.
    Rakhi, R. B.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (50) : 43343 - 43351
  • [24] GRAPHITE ELECTRODES IN ELECTROCHEMICAL METHODS OF ANALYSIS
    BARIKOV, VG
    SONGINA, OA
    [J]. INDUSTRIAL LABORATORY, 1964, 30 (01): : 3 - 6
  • [25] Adsorption and electrooxidation of nucleic acids at carbon nanotubes paste electrodes
    Pedano, ML
    Rivas, GA
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (01) : 10 - 16
  • [26] Carbon nanotubes paste electrodes as new detectors for capillary electrophoresis
    Chicharro, M
    Sánchez, A
    Bermejo, E
    Zapardiel, A
    Rubianes, MD
    Rivas, GA
    [J]. ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) : 84 - 91
  • [27] Powdered activated carbon and carbon paste electrodes: comparison of electrochemical behaviour
    Biniak, S.
    Pakula, M.
    Darlewski, W.
    Swiatkowski, A.
    Kula, P.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (05) : 593 - 600
  • [28] Powdered activated carbon and carbon paste electrodes: Comparison of electrochemical behaviour
    Biniak, S.
    Pakula, M.
    Darlewski, W.
    Świątkowski, A.
    Kula, P.
    [J]. Journal of Applied Electrochemistry, 2009, 39 (05): : 593 - 600
  • [29] Powdered activated carbon and carbon paste electrodes: comparison of electrochemical behaviour
    S. Biniak
    M. Pakuła
    W. Darlewski
    A. Świątkowski
    P. Kula
    [J]. Journal of Applied Electrochemistry, 2009, 39 : 593 - 600
  • [30] Graphite-Epoxy Electrodes Modified with Functionalised Carbon Nanotubes and Chitosan for the Rapid Electrochemical Determination of Dipyrone
    Pauliukaite, Rasa
    Ghica, Mariana Emilia
    Fatibello-Filho, Orlando
    Brett, Christopher M. A.
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2010, 13 (07) : 590 - 598