Catenary action in steel-framed buildings

被引:0
|
作者
Byfield, M. [1 ]
Paramasivam, S. [1 ]
机构
[1] Univ Southampton, Sch Civil Engn & Environm, Southampton SO9 5NH, Hants, England
关键词
steel structures; building structures & design; design methods & aids;
D O I
10.1680/stbu.2007.160.5.247
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current paper is of relevance to engineers engaged in the design of buildings in which severe column damage resulting from malicious actions is a design scenario. The tying force method as used for providing robustness to steel-framed buildings relies upon catenary action to redistribute loads following column damage. Fortunately severe column damage is extremely rare and for this reason it is not well understood if this load redistribution mechanism is reliable. The current paper presents results of an investigation into the tying force method by way of a case study of a steel-framed building in which support to a perimeter column is removed. Results indicate that industry standard beam - column connections possess insufficient ductility to accommodate the large floor displacements that occur during catenary action and the factor of safety against collapse is shown to be less than 0.2.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 50 条
  • [21] The influence of shear connectors on the behaviour of composite steel-framed buildings in fire
    Huang, ZH
    Burgess, IW
    Plank, RJ
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 51 (03) : 219 - 237
  • [22] Structural Fire Analysis of One-storey Steel-framed Buildings with Steel Claddings
    Ma, Zhongcheng
    Havula, Jarmo
    Mela, Kristo
    Kesti, Jyrki
    ce/papers, 2021, 4 (2-4) : 1213 - 1222
  • [23] BUYING A STEEL-FRAMED BUILDING
    JOHNSTON, CA
    ROBINSON, TW
    FARM BUILDING PROGRESS, 1990, (100): : 19 - 22
  • [24] WIND DRIFT DESIGN OF STEEL-FRAMED BUILDINGS - STATE-OF-THE-ART REPORT
    不详
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1988, 114 (09): : 2085 - 2108
  • [25] Metrics for the assessment of structural design efficiency applied to steel-framed industrial buildings
    University of Coimbra, ISISE, ARISE, Department of Civil Engineering, Coimbra, Portugal
    不详
    ce/Pap., 3-4 (226-231): : 226 - 231
  • [26] EVALUATION OF THE ECONOMIC EFFICIENCY OF HONEYCOMB GIRDERS OF ROOFS OF INDUSTRIAL STEEL-FRAMED BUILDINGS
    Petersen, Tobias
    Krahwinkel, Manuel
    Behrens, Matthias
    IMPLEMENTING INNOVATIVE IDEAS IN STRUCTURAL ENGINEERING AND PROJECT MANAGEMENT, 2015, : 1259 - 1264
  • [27] Numerical investigation into the effectiveness of steel i-beam strengthening techniques in steel-framed buildings
    Alhammadi, S. A.
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2021, 18 (07)
  • [28] Methods for improving the thermal performance of thermal bridges of lightweight steel-framed buildings
    Qi, Xuejun
    Tan, Yuxin
    Tan, Jinsheng
    Li, Xiaohong
    PLOS ONE, 2024, 19 (12):
  • [29] Unique steel-framed solution to parking
    1600, (American Institute of Steel Construction Inc.):
  • [30] Contact resistance in a steel-framed wall
    Trethowen, H.A.
    Cox-Smith, I.
    Journal of thermal insulation and building envelopes, 1996, 20 : 132 - 143