The current paper is of relevance to engineers engaged in the design of buildings in which severe column damage resulting from malicious actions is a design scenario. The tying force method as used for providing robustness to steel-framed buildings relies upon catenary action to redistribute loads following column damage. Fortunately severe column damage is extremely rare and for this reason it is not well understood if this load redistribution mechanism is reliable. The current paper presents results of an investigation into the tying force method by way of a case study of a steel-framed building in which support to a perimeter column is removed. Results indicate that industry standard beam - column connections possess insufficient ductility to accommodate the large floor displacements that occur during catenary action and the factor of safety against collapse is shown to be less than 0.2.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 50 条
  • [1] Catenary action in steel framed buildings with buckling restrained braces
    Eletrabi, Haitham
    Marshall, Justin D.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 113 : 221 - 233
  • [2] Cathodic protection of steel-framed buildings
    Drewett, JF
    MATERIALS PERFORMANCE, 2002, 41 (01) : 36 - 40
  • [3] Behavior of steel-framed buildings in a fire
    Al-Jabri, Khalifa S.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2007, 7 (03) : 227 - 237
  • [4] Cathodic protection of early steel-framed buildings
    Gibbs, Peter
    Chaudhary, Zia
    Structural Engineer, 1999, 77 (10): : 11 - 14
  • [5] Reliability assessment of steel-framed industrial buildings
    da Silva, Luís Simões
    Ljubinković, Filip
    Janković, Milena
    Silva, Catarina
    Gervásio, Helena
    Conde, Jorge
    Tankova, Trayana
    ce/papers, 2023, 6 (3-4) : 854 - 859
  • [6] The influence of tensile membrane action in concrete slabs on the behaviour of composite steel-framed buildings in fire
    Huang, Zhaohui
    Burgess, Ian W.
    Plank, Roger J.
    Struct. Congr.: Struct. - Struct. Eng Odyssey, 1600,
  • [7] Analyses of the effects of cooling and fire spread on steel-framed buildings
    Bailey, CG
    Burgess, IW
    Plank, RJ
    FIRE SAFETY JOURNAL, 1996, 26 (04) : 273 - 293
  • [8] PROGRESSIVE COLLAPSE OF STEEL-FRAMED BUILDINGS: INFLUENCE OF MODELLING APPROACH
    Yu, Hang
    Izzuddin, Bassam A.
    Zha, Xiao-Xiong
    ADVANCED STEEL CONSTRUCTION, 2010, 6 (04): : 932 - 948
  • [9] Overall stability analysis of oversized steel-framed buildings in a fire
    Zhang, Guowei
    Zhu, Guoqing
    Yuan, Guanglin
    Li, Qing
    FIRE AND MATERIALS, 2016, 40 (02) : 273 - 288
  • [10] Economical steel-framed high-rise residential buildings
    Huzzard, Robert K.
    Larson, Jay W.
    Steel Construction (Sydney, Australia), 1988, 22 (04): : 2 - 9