Removal of Iron and Manganese Using Cascade Aerator and Limestone Roughing Filter

被引:4
|
作者
Sanusi, Azrin Mohd [1 ]
Adlan, Mohd Nordin [1 ]
Rozainy, M. A. Z. Mohd Remy [1 ]
Jamil, Rhahimi [1 ]
机构
[1] Univ Sains Malaysia, Fac Civil Engn, Nibong Tebal 14300, Pulau Pinang, Malaysia
来源
3RD INTERNATIONAL CONFERENCE ON CIVIL AND ENVIRONMENTAL ENGINEERING FOR SUSTAINABILITY (ICONCEES 2015) | 2016年 / 47卷
关键词
WATER; GROUNDWATER;
D O I
10.1051/matecconf/20164705006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Combination between oxidation and filtration can be used for removing iron and manganese from groundwater especially when the concentrations of these metals were high. This study focused on the effectiveness of the cascade aerator and the size of the limestone filter media to remove iron and manganese from groundwater. Water samples used for this study were collected from orphanage home, Rumah Nur Kasih, Taiping. Universiti Sains Malaysia (USM) has provided a tube well of 15 m depth and 150 mm diameter for the orphanage home. However, the water cannot be used for domestic consumption due to high amount of iron and manganese at 6.48 and 1.9 mg/L which exceeded the drinking water standard of 0.3 and 0.1 mg/L respectively. Using laboratory physical model, the study has shown that the removals of iron and manganese have reduce the concentration until 0.17 and 0.2 mg/L respectively. Thus, the results from this study which utilize cascade aerator and limestone roughing filter could be implemented on site for the community to use the ground water for domestic purposes.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] The need for iron and manganese removal
    Tuomala, JMW
    PROCEEDINGS OF THE SMALL DRINKING WATER AND WASTEWATER SYSTEMS: TECHNOLOGY FOR THE 21ST CENTURY, 2000, : 307 - 316
  • [42] Softening, iron and manganese removal
    Public Works, 1992, 123 (05):
  • [43] Microbial Community Analysis in Bio-filter Bed of Iron and Manganese Removal Treating High Iron, Manganese and Ammonia Nitrogen Groundwater
    Kang, Xiaorong
    Liu, Yali
    ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING (2013), 2013, 777 : 238 - +
  • [44] REMOVAL OF SULFUR CONTENT IN GROUNDWATER USING MARBLE FILTER IN A CASCADE DESIGN
    Akhir, M. F. M.
    Saad, N. A.
    Zabidi, H.
    Zainol, M. R. R. M. A.
    ARCHIVES OF METALLURGY AND MATERIALS, 2024, 69 (04) : 1643 - 1648
  • [45] Iron and manganese removal by using manganese ore constructed wetlands in the reclamation of steel wastewater
    Xu, Jing-Cheng
    Chen, Gu
    Huang, Xiang-Feng
    Li, Guang-Ming
    Liu, Jia
    Yang, Na
    Gao, Sai-Nan
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) : 309 - 317
  • [46] Physico-chemical removal of iron from semi-aerobic landfill leachate by limestone filter
    Aziz, HA
    Yusoff, MS
    Adlan, MN
    Adnan, NH
    Alias, S
    WASTE MANAGEMENT, 2004, 24 (04) : 353 - 358
  • [47] A STUDY INTO THE REMOVAL OF IRON FROM FERRUGINOUS GROUNDWATER USING LIMESTONE BED FILTRATION
    SMITH, PG
    GABER, A
    HATTAB, I
    HALIM, HA
    WATER SCIENCE AND TECHNOLOGY, 1993, 27 (09) : 23 - 28
  • [48] Removal of iron from potable water using a trickling filter
    Michalakos, GD
    Nieva, JM
    Vayenas, DV
    Lyberatos, G
    WATER RESEARCH, 1997, 31 (05) : 991 - 996
  • [49] Manganese removal from New Zealand coal mine drainage using limestone leaching beds
    Christenson, Hana
    Pope, James
    Trumm, Dave
    Uster, Ben
    Newman, Nigel
    Young, Mike
    MINING MEETS WATER - CONFLICTS AND SOLUTIONS, 2016, : 906 - 912
  • [50] Efficient chemical and microbial removal of iron and manganese in a rapid sand filter and impact of regular backwash
    Haukelidsaeter, Signe
    Boersma, Alje S.
    Piso, Lina
    Lenstra, Wytze K.
    van Helmond, Niels A. G. M.
    Schoonenberg, Frank
    van der Pol, Erik
    Hurtarte, Luis C. C.
    van der Wielen, Paul W. J. J.
    Behrends, Thilo
    van Kessel, Maartje A. H. J.
    Lucker, Sebastian
    Slomp, Caroline P.
    APPLIED GEOCHEMISTRY, 2024, 162