Rapid quantification of nebivolol in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:54
|
作者
Ramakrishna, NS [1 ]
Vishwottam, KN [1 ]
Koteshwara, M [1 ]
Manoj, S [1 ]
Santosh, M [1 ]
Varma, DP [1 ]
机构
[1] Suven Life Sci Ltd, Biopharmaceut Res, Hyderabad 500034, Andhra Pradesh, India
关键词
nebivolol; reversed-phase chromatography; tandem mass spectrometry; multiple reaction monitoring; human plasma; pharmacokinetic study;
D O I
10.1016/j.jpba.2005.05.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantitation of nebivolol in human plasma. The method involved a simple single-step liquid-liquid extraction with diethyl ether/dichloromethane (70/30). The analyte was chromatographed on Waters symmetry (R) C-18 reversed-phase chromatographic column by isocratic elution with water: acetonitrile: formic acid (30:70:0.03, nu/nu) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 406.4-151.5 and m/z 409.1-228.1 were used to measure the analyte and the internal standard (I.S.), respectively. The chromatographic runtime was 2 min and the weighted (1/x(2)) calibration curves were linear over the range 50-10,000 pg/mL. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 10 and 50 pg/mL, respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<10%). The analyte was stable after three freeze-thaw cycles (deviation <10%). The average absolute recoveries of nebivolol and tamsulosin, used as an internal standard, from spiked plasma samples were 73.4 +/- 3.7 and 72.1 +/- 2.0%, respectively. The assay method described here was applied to study the pharmacokinetics of nebivolol. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1006 / 1013
页数:8
相关论文
共 50 条
  • [41] Identification and quantification of salinomycin in intoxicated human plasma by liquid chromatography–electrospray tandem mass spectrometry
    Yu Li
    Junjian Fang
    Shengming Wu
    Kunpeng Ma
    Haijing Li
    Xianzhong Yan
    Fangting Dong
    [J]. Analytical and Bioanalytical Chemistry, 2010, 398 : 955 - 961
  • [42] Liquid chromatography/electrospray ionization mass spectrometry method for the quantification of valproic acid in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Santosh, M
    Chidambara, J
    Kumar, BR
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 1970 - 1978
  • [43] Quantification of artemisinin in human plasma using liquid chromatography coupled to tandem mass spectrometry
    Lindegardh, N.
    Tarning, J.
    Toi, P. V.
    Hien, T. T.
    Farrar, J.
    Singhasivanon, P.
    White, N. J.
    Ashton, M.
    Day, N. P. J.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 768 - 773
  • [44] Rapid determination of coumatetralyl in human serum by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Jin, Mi-cong
    OuYang, Xiao-kun
    Xu, Xiao-min
    Ren, Yi-ping
    Chen, Xiao-hong
    [J]. ANALYTICAL LETTERS, 2007, 40 (04) : 737 - 746
  • [45] Liquid chromatography/electrospray ionization tandem mass spectrometry for the quantification of mitiglinide in human plasma: validation and its application to pharmacokinetic studies
    Zhang, Yan
    Ding, Likun
    Tian, Yun
    Yang, Jing
    Yang, Lin
    Wen, Aidong
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (08) : 873 - 878
  • [46] Rapid quantitative analysis of oxiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Son, J
    Lee, J
    Lee, M
    Lee, E
    Lee, KT
    La, S
    Kim, DH
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 183 - 187
  • [47] Rapid quantitative analysis of oxiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Son, J
    Lee, J
    Lee, M
    Lee, E
    Lee, JH
    La, S
    Kim, DH
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) : 657 - 661
  • [48] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    [J]. JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [49] Simultaneous quantification of oleuropein and its metabolites in rat plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Bazoti, Fotini N.
    Gikas, Evangelos
    Tsarbopoulos, Anthony
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 506 - 515
  • [50] Analysis of tomato glycoalkaloids by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cataldi, TRI
    Lelario, F
    Bufo, SA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 3103 - 3110