Rapid quantification of nebivolol in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:54
|
作者
Ramakrishna, NS [1 ]
Vishwottam, KN [1 ]
Koteshwara, M [1 ]
Manoj, S [1 ]
Santosh, M [1 ]
Varma, DP [1 ]
机构
[1] Suven Life Sci Ltd, Biopharmaceut Res, Hyderabad 500034, Andhra Pradesh, India
关键词
nebivolol; reversed-phase chromatography; tandem mass spectrometry; multiple reaction monitoring; human plasma; pharmacokinetic study;
D O I
10.1016/j.jpba.2005.05.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantitation of nebivolol in human plasma. The method involved a simple single-step liquid-liquid extraction with diethyl ether/dichloromethane (70/30). The analyte was chromatographed on Waters symmetry (R) C-18 reversed-phase chromatographic column by isocratic elution with water: acetonitrile: formic acid (30:70:0.03, nu/nu) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 406.4-151.5 and m/z 409.1-228.1 were used to measure the analyte and the internal standard (I.S.), respectively. The chromatographic runtime was 2 min and the weighted (1/x(2)) calibration curves were linear over the range 50-10,000 pg/mL. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 10 and 50 pg/mL, respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<10%). The analyte was stable after three freeze-thaw cycles (deviation <10%). The average absolute recoveries of nebivolol and tamsulosin, used as an internal standard, from spiked plasma samples were 73.4 +/- 3.7 and 72.1 +/- 2.0%, respectively. The assay method described here was applied to study the pharmacokinetics of nebivolol. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1006 / 1013
页数:8
相关论文
共 50 条
  • [1] Quantification of Paroxetine in Human Plasma by Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Shah, Hiten J.
    Kundlik, Mohan L.
    Kakad, Abhijit
    Patel, Nitesh K.
    Pandya, Ankit
    Khatri, Vanita
    Prajapati, Shivkumat
    Subbaiah, Gunta
    Patel, Chhagan N.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (01) : 141 - 149
  • [2] Quantification of granisetron in human plasma by liquid chromatography coupled to electrospray tandem mass spectrometry
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikumar
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 888 - 897
  • [3] Determination and Quantification of Phenytoin in Human Plasma by Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
    Roy, S. M. N.
    Yetal, S. M.
    Vaidya, V. V.
    Joshi, S. S.
    [J]. E-JOURNAL OF CHEMISTRY, 2008, 5 (01) : 169 - 176
  • [4] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742
  • [5] Rapid Quantification of Efavirenz in Human Plasma by Electrospray Ionization Tandem Mass Spectrometry
    Kailasa, Suresh Kumar
    Wu, Hui-Fen
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (04) : 437 - 441
  • [6] Rapid quantification of HIV protease inhibitors in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Crommentuyn, KML
    Rosing, H
    Nan-Offeringa, LGAH
    Hillebrand, MJX
    Huitema, ADR
    Beijnen, JH
    [J]. JOURNAL OF MASS SPECTROMETRY, 2003, 38 (02): : 157 - 166
  • [7] Quantification of clomiphene metabolite isomers in human plasma by rapid-resolution liquid chromatography–electrospray ionization–tandem mass spectrometry
    Boian Ganchev
    Georg Heinkele
    Reinhold Kerb
    Matthias Schwab
    Thomas E. Mürdter
    [J]. Analytical and Bioanalytical Chemistry, 2011, 400 : 3429 - 3441
  • [8] Quantification of vigabatrin in human plasma by liquid chromatography - Electrospray tandem mass spectrometry
    Matar, KM
    Abdel-Hamid, ME
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 395 - 406
  • [9] Quantification of roxatidine in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry: Application to a bioequivalence study
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Heon-Woo
    Choi, Seung-Ki
    Lee, Kyung-Tae
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 143 - 147
  • [10] Sensitive quantification of ranolazine in human plasma by liquid chromatography-tandem mass spectrometry with positive electrospray ionization
    Tian, Lei
    Jiang, Juanjuan
    Huang, Yiling
    Hua, Lu
    Liu, Hong
    Li, Yishi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 346 - 350