IMPEDANCE PROTECTION FOR POWER TRANSFORMERS

被引:0
|
作者
Steynberg, Gustav [1 ]
机构
[1] Siemens AG, Energy Management Div, Nurnberg, Germany
来源
2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS | 2015年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The distance protection principle, when applied to over-head lines and cables, is well known, widely applied and well proven. Also on large generating blocks it is often applied as one of the back-up protection functions. When it comes to typical power transformers, the conventional distance protection however has some limitations which have limited its application in this context. Due to the increase in decentralized generation the risk of not clearing transformer or high voltage faults from the low voltage side has increased. The inherent remote back-up functionality in the impedance principle presents itself as an ideal measure for addressing this risk. The paper will show what is possible with an impedance based protection function in terms of detecting faults in and "through" a transformer. In particular the ability to apply the impedance protection function at the low voltage side of the transformer will be addressed. The focus will be on the need for zone specific impedance measuring principles for different tasks. Compared with conventional distance protection where it is only possible to apply a single method for all zones. It will be shown why the conventional distance protection will often fail to produce the desired results due to the inability to measure with the optimum elements (loops). The manner in which faults are "mapped" onto the measuring loops via the transformer winding arrangement and vector group are keys to understanding the impedance protection in this context. Some simulation results will be used to confirm the theoretical findings. An application example will be used to shown the implementation with a focus on setting coordination.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 50 条
  • [31] Protection of Terminal Distribution Transformers: A Case Study of Kenya Power
    Muriuki, James
    Muriithi, Christopher M.
    Ngoo, Living
    Nyakoe, George N.
    2018 IEEE PES/IAS POWERAFRICA CONFERENCE, 2018, : 408 - 413
  • [32] Algorithm using Discrete Wavelet Transform to Power Transformers Protection
    Marques, Jeferson Prates
    Oliveira, Aecio
    Cardoso Junior, Ghendy
    2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [33] Evaluation of Low Power Instrument Transformers for Generator Differential Protection
    Normandeau, Michel
    Mahseredjian, Jean
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [34] IMPROVED OPERATION OF DIFFERENTIAL PROTECTION OF POWER TRANSFORMERS FOR INTERNAL FAULTS
    LIU, P
    MALIK, OP
    CHEN, DS
    HOPE, GS
    GUO, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) : 1912 - 1919
  • [36] A Power Divider Utilizing Stepped Impedance Transformers For Real/Complex Port Terminations
    Gupta, Rahul
    Singh, Vikas V.
    Hashmi, Mohammad
    PROCEEDINGS OF THE 2019 IEEE ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2019, : 312 - 314
  • [37] Filtering push-pull power amplifier based on novel impedance transformers
    Zhang, Bo
    Dong, Gaoya
    Wu, Yongle
    Yu, Cuiping
    Liu, Yuanan
    ELECTRONICS LETTERS, 2016, 52 (17) : 1467 - 1468
  • [38] A Contribution to the Analysis of Frequency Response and Impedance Measurements to Evaluation and Diagnostic of Power Transformers
    Martins, Helvio J. A.
    Urbani, Bruno
    Ferreira, Cintia de Faria
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 566 - 569
  • [39] Sensitive Protection of Power Transformers for Internal Inter-Turn Faults
    Wiszniewski, A.
    Rebizant, W.
    Schiel, L.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 331 - +
  • [40] APPLICATION OF KALMAN FILTER FOR DIGITAL DIFFERENTIAL PROTECTION RELAY OF POWER TRANSFORMERS
    Ivanchenko, D. I.
    Shonin, O. B.
    JOURNAL OF MINING INSTITUTE, 2012, 195 : 255 - 258