Measurement-based extrapolation of spectral responsivity by using a low-NEP pyroelectric detector

被引:2
|
作者
Park, Seongchong [1 ]
Lee, Dong-Hoon [1 ]
Hong, Kee Suk [2 ]
机构
[1] Korea Res Inst Stand & Sci KRISS, Div Phys Metrol, Daejeon, South Korea
[2] Korea Res Inst Stand & Sci KRISS, Quantum Technol Inst, Daejeon, South Korea
关键词
spectral responsivity; pyroelectric detector; silicon trap detector; SCALE; REALIZATION;
D O I
10.1088/1361-6501/ac3626
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In case the primary realization of the spectral responsivity scale is not conducted at all target wavelengths but at only a small part of them, one needs to extrapolate values at the specific wavelengths to an extended range. In this work, we present a fully experimental procedure to extrapolate a single value of spectral responsivity at 633 nm into the whole working wavelength range (250-1100) nm of Si photodiodes. It is based on spectral responsivity comparison between a Si trap detector and a low-noise equivalent power pyroelectric detector of nearly flat spectral response. For this purpose, we developed a setup specialized to compare a Si-trap detector of dc-current output with a pyroelectric detector of ac-voltage output by using a modulated probing light source and a monitoring technique. To keep the probing light chopped even for the dc-photocurrent readout, we adopted a low chopping frequency of 4 Hz and a triggered readout for the Si-trap detector, which leads to a speedy comparison between the Si-trap detector and the pyroelectric detector. For the reference pyroelectric detector, we characterized the spectral absorptivity of the black-coating and the nonlinearity of the lock-in amplifier readout. Compiling all the required information, the spectral responsivity of the Si trap detector could be measured with the minimum uncertainty of 0.3% (k = 2), which was validated by comparing with that of our previous method based on a numerical extrapolation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Measurement of the absolute spectral responsivity in the mid-infrared based on the cryogenic electrical substitution radiometer and an optimized thermopile detector
    Pohl, Tobias
    Meindl, Peter
    Johannsen, Uwe
    Taubert, Dieter
    Werner, Lutz
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2019, 8 (01) : 195 - 205
  • [22] Extension of a silicon-based detector spectral-responsivity scale into the ultraviolet
    New Zealand Inst for Industrial, Research Development, Lower Hutt, New Zealand
    Metrologia, 6 (497-500):
  • [23] Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer
    Shi, Xueshun
    Liu, Changming
    Liu, Yulong
    Yang, Lechen
    Zhao, Kun
    Chen, Haidong
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [25] Calibration Method for spectral responsivity of Infrared Detector based on Blackbody at Multiple Temperature
    Zhang, Y. F.
    Shao, Z. F.
    Wu, Y. Q.
    2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2015, 9623
  • [26] The technique of measuring absolute spectral responsivity of InGaAs detector based on cryogenic radiometer
    Fan, JH
    Yang, ZJ
    Hou, XQ
    Qin, Y
    Li, ZQ
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [27] Improving Precision of RCS Measurement Based on Spectral Extrapolation Method
    Hu, Chufeng
    Li, Nanjing
    Chen, Weijun
    Guo, Shuxia
    2020 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (2020 ACES-MONTEREY), 2020,
  • [28] Spectral responsivity measurement of uncooled IRFPA using free electron laser
    Ishikawa, T
    Ueno, M
    Kimata, M
    Seto, T
    Tsubouchi, N
    INFRARED TECHNOLOGY AND APPLICATIONS XXV111, PTS 1 AND 2, 2003, 4820 : 254 - 260
  • [29] High responsivity of pyroelectric infrared detector based on ultra-thin (10 μm) LiTaO3
    Liang, Zhiqing
    Li, Shibin
    Liu, Ziji
    Jiang, Yadong
    Li, Weizhi
    Wang, Tao
    Wang, Jun
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2015, 26 (07) : 5400 - 5404
  • [30] High responsivity of pyroelectric infrared detector based on ultra-thin (10 μm) LiTaO3
    Zhiqing Liang
    Shibin Li
    Ziji Liu
    Yadong Jiang
    Weizhi Li
    Tao Wang
    Jun Wang
    Journal of Materials Science: Materials in Electronics, 2015, 26 : 5400 - 5404