The performance of a fluoroscopic electronic portal imaging device modified for portability

被引:3
|
作者
Kirby, MC [1 ]
Atherton, S [1 ]
Carson, P [1 ]
McDonagh, C [1 ]
Sykes, JR [1 ]
Williams, PC [1 ]
机构
[1] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
来源
BRITISH JOURNAL OF RADIOLOGY | 1999年 / 72卷 / 862期
关键词
D O I
10.1259/bjr.72.862.10673953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Advances in external beam therapy technology have made routine, efficient conformal therapy a reality. With it comes the increasing need for online treatment verification, which is only achievable at present through the use of electronic portal imaging devices (EPIDs). For a large radiotherapy centre, the provision of one EPID per treatment machine proves extremely expensive. This paper details modifications to the design of a commercial fluoroscopic EPID (the SRI-100) to produce a portable system, capable of providing quick, high quality imaging on more than one treatment machine. We describe the necessary hardware and software changes made to the system, as well as the variety of mechanical and quality control checks performed for testing the stability and quality of the imaging. The modified system has been found to be both electronically and mechanically robust, with associated image quality, scaling, distortion and movement similar to other EPIDs in the department. Although the modification was designed specifically to allow for the acquisition of images from multiple treatment machines, it may also enable the operation of the EPID for other uses such as total body irradiation (TBI) treatment verification and a further range of quality control procedures on the linear accelerator itself.
引用
收藏
页码:1000 / 1005
页数:6
相关论文
共 50 条
  • [31] The fast calibration model for dosimetry with an electronic portal imaging device
    Schade, Stephanie
    Engenhart-Cabillic, Rita
    Zink, Klemens
    Czarnecki, Damian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):
  • [32] Detective quantum efficiency analysis of an electronic portal imaging device
    Li, H
    Goddu, SM
    Esthappan, J
    Mutic, S
    Rong, XJ
    MEDICAL PHYSICS, 2005, 32 (06) : 2004 - 2004
  • [33] The effect of respiratory motion on electronic portal imaging device dosimetry
    Fielding, Andrew L.
    Mendieta, Jessica Benitez
    Maxwell, Sarah
    Jones, Catherine
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03): : 45 - 55
  • [34] Evaluating Electronic Portal Imaging Device for small field measurements
    Sait, A. A.
    Patel, T.
    Rastogi, N.
    Yoganathan, S.
    Mani, S.
    Berilgen, J.
    Boopathy, R.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1311 - S1312
  • [35] Verification of the optimal backscatter for an aSi electronic portal imaging device
    Moore, JA
    Siebers, JV
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10): : 2341 - 2350
  • [36] Spatial and contrast resolution of a new electronic portal imaging device
    Kruse, J
    Herman, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2024 - 2024
  • [37] Considerations about the technical properties of an electronic portal imaging device
    Hilsebecher, J
    Bortfeld, T
    Schlegel, W
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 285 - 287
  • [38] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    Afzalifar, A.
    Mowlavi, A. A.
    Mohammadi, M.
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 195 - 200
  • [39] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    A. Afzalifar
    A. A. Mowlavi
    M. Mohammadi
    Radiological Physics and Technology, 2020, 13 : 195 - 200
  • [40] Commissioning and periodic quality assurance of a clinical electronic portal imaging device
    Low, DA
    Klein, EE
    Maag, DK
    Umfleet, WE
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01): : 117 - 123