In-flight calibration and performance of the Mars Exploration Rover Panoramic Camera (Pancam) instruments

被引:92
|
作者
Bell, JF
Joseph, J
Sohl-Dickstein, JN
Arneson, HM
Johnson, MJ
Lemmon, MT
Savransky, D
机构
[1] Cornell Univ, Dept Astron, Ithaca, NY 14853 USA
[2] Texas A&M Univ, Dept Atmospher Sci, College Stn, TX 77843 USA
关键词
D O I
10.1029/2005JE002444
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The Mars Exploration Rover Panoramic Camera ( MER/Pancam) instruments have acquired more than 60,000 high-resolution, multispectral, stereoscopic images of soil, rocks, and sky at the Gusev crater and Meridiani Planum landing sites since January 2004. These images, combined with other MER data sets, have enabled new discoveries about the composition, mineralogy, and geologic/geochemical evolution of both sites. One key to the success of Pancam in contributing to the overall success of MER has been the development of a calibration pipeline that can quickly remove instrumental artifacts and generate both absolute radiance and relative reflectance images with high accuracy and precision in order to influence tactical rover driving and in situ sampling decisions. This paper describes in detail the methods, assumptions, and models/algorithms in the calibration pipeline developed for Pancam images, based on new measurements and refinements performed primarily from flight data acquired on Mars. Major calibration steps include modeling and removal of detector bias signal, active and readout region dark current, electronic "shutter smear,'' and pixel-to-pixel responsivity ( flatfield) variations. Pancam images are calibrated to radiance ( W/m(2)/nm/sr) using refined preflight-derived calibration coefficients, or radiance factor ( I/F) using near-in-time measurements of the Pancam calibration target and a model of aeolian dust deposition on the target as a function of time. We are able to verify that the absolute radiance calibration of most Pancam images is accurate to within about 10% or less and that the filter-to-filter and pixel-to-pixel precision of the calibrated relative reflectance data ( both based on measurements of the Pancam calibration target) are typically about 3% and 1% or less, respectively. Examples are also presented of scientific applications made possible by the high fidelity of the calibrated Pancam data. These include 11-color visible to near-IR spectral analysis, calculation of "true color'' and chromaticity values, and generation of "super resolution'' image data products. This work represents a follow-on and enhancement to the Pancam preflight calibration process described by Bell et al. ( 2003).
引用
收藏
页数:38
相关论文
共 50 条
  • [31] In-flight performance of the Advanced Camera for Surveys CCDS
    Clampin, M
    Sirianni, M
    Hartig, GF
    Ford, HC
    Illingworth, GD
    Burmester, B
    Koldewynd, W
    Martel, AR
    Riess, A
    Schrein, RJ
    Sullivan, PC
    SCIENTIFIC DETECTORS FOR ASTRONOMY: THE BEGINNING OF A NEW ERA, 2004, 300 : 555 - 564
  • [32] The ISGRI CdTe gamma camera in-flight performance
    Lebrun, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3119 - 3123
  • [33] In-flight Performance of the Advanced Camera for Surveys CCDs
    Mark Clampin
    Marco Sirianni
    George F. Hartig
    Holland C. Ford
    Garth D. Illingworth
    Bill Burmester
    William Koldewynd
    Andre R. Martel
    Adam Riess
    Ronald J. Schrein
    Pamela C. Sullivan
    Experimental Astronomy, 2002, 14 : 107 - 115
  • [34] Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite
    Golish, D. R.
    Drouet d'Aubigny, C.
    Rizk, B.
    DellaGiustina, D. N.
    Smith, P. H.
    Becker, K.
    Shultz, N.
    Stone, T.
    Barker, M. K.
    Mazarico, E.
    Tatsumi, E.
    Gaskell, R. W.
    Harrison, L.
    Merrill, C.
    Fellows, C.
    Williams, B.
    O'Dougherty, S.
    Whiteley, M.
    Hancock, J.
    Clark, B. E.
    Hergenrother, C. W.
    Lauretta, D. S.
    SPACE SCIENCE REVIEWS, 2020, 216 (01)
  • [35] In-flight performance of the advanced camera for surveys CCDs
    Clampin, M
    Sirianni, M
    Hartig, GF
    Ford, HC
    Illingworth, GD
    Burmester, B
    Koldewynd, W
    Martel, AR
    Riess, A
    Schrein, RJ
    Sullivan, PC
    EXPERIMENTAL ASTRONOMY, 2002, 14 (02) : 107 - 115
  • [36] In-flight performance of the Chandra High Resolution Camera
    Murray, SS
    Austin, G
    Chappell, J
    Gomes, J
    Kenter, A
    Kraft, R
    Meehan, G
    Zombeck, M
    Fraser, G
    Serio, S
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 68 - 80
  • [37] New method for in-flight calibration of camera's intersection angle
    Liu, Jiangwei, 1600, Chinese Society of Astronautics (43):
  • [38] In-flight photogrammetric camera calibration and validation via complementary lidar
    Gneeniss, A. S.
    Mills, J. P.
    Miller, P. E.
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2015, 100 : 3 - 13
  • [39] Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite
    D. R. Golish
    C. Drouet d’Aubigny
    B. Rizk
    D. N. DellaGiustina
    P. H. Smith
    K. Becker
    N. Shultz
    T. Stone
    M. K. Barker
    E. Mazarico
    E. Tatsumi
    R. W. Gaskell
    L. Harrison
    C. Merrill
    C. Fellows
    B. Williams
    S. O’Dougherty
    M. Whiteley
    J. Hancock
    B. E. Clark
    C. W. Hergenrother
    D. S. Lauretta
    Space Science Reviews, 2020, 216
  • [40] IN-FLIGHT AERIAL CAMERA CALIBRATION FROM PHOTOGRAPHY OF LINEAR FEATURES
    FRYER, JG
    GOODIN, DJ
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1989, 55 (12): : 1751 - 1754