Retarding field analyser used in elastic peak electron spectroscopy

被引:18
|
作者
Zeze, D [1 ]
Bideux, L [1 ]
Gruzza, B [1 ]
Golek, F [1 ]
Danko, D [1 ]
Mroz, S [1 ]
机构
[1] UNIV WROCLAW,INST EXPT PHYS,PL-50204 WROCLAW,POLAND
关键词
D O I
10.1016/S0042-207X(96)00296-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The percentage, eta(e), of electrons elastically reflected by a substrate is a fundamental parameter for elastic peak electron spectroscopy (EPES). A Retarding Field Analyser with ifs large acceptance angle can be used for this spectroscopy. However, distortion is observed in the low energy side of the recorded elastic peak, increasing with the energy of the impinging electrons, which introduces difficulty for eta(e) measurement. To eliminate this difficulty, we propose in this paper a method to obtain eta(e) using a reference curve. The process is applied to the study of the Ag/Mo system, as well as experimental determination of the mean free path of electrons in indium samples. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:399 / 401
页数:3
相关论文
共 50 条
  • [41] Angle-resolved elastic peak electron spectroscopy: Role of surface excitations
    Jablonski, A.
    Zemek, J.
    SURFACE SCIENCE, 2007, 601 (16) : 3409 - 3420
  • [42] Determination of the Relative Concentration of Deuterium Implanted into Beryllium by Elastic Peak Electron Spectroscopy
    V. P. Afanas’ev
    A. S. Gryazev
    P. S. Kaplya
    M. Köppen
    A. V. Rybakova
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2019, 13 : 828 - 831
  • [43] Improvement of the depth resolution in sputter depth profiling by elastic peak electron spectroscopy
    Kesler, V
    Hofmann, S
    SURFACE AND INTERFACE ANALYSIS, 2002, 33 (08) : 635 - 639
  • [44] SOME PROBLEMS OF ELECTRON-SPECTROSCOPY (AES, EPES) USING A RETARDING-FIELD ANALYZER
    SULYOK, A
    GERGELY, G
    GRUZZA, B
    BIDEUX, L
    VACUUM, 1994, 45 (2-3) : 325 - 327
  • [45] Retarding Field Integrated Fluorescence and Electron Microscope
    Vos, Yoram
    Lane, Ryan, I
    Peddie, Chris J.
    Wolters, Anouk H. G.
    Hoogenboom, Jacob P.
    MICROSCOPY AND MICROANALYSIS, 2021, 27 (01) : 109 - 120
  • [46] A kinetic model of retarding field analyser measurements in strongly magnetized, flowing, collisional plasmas
    Gunn, J. P.
    Fuchs, V.
    Kocan, M.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2013, 55 (04)
  • [47] Ion energy analysis of a bipolar HiPIMS discharge using a retarding field energy analyser
    Walk, F.
    Valizadeh, R.
    Bradley, J. W.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2022, 31 (06):
  • [48] SAMPLE POTENTIAL MODULATION FOR SPECTROSCOPY OF ELECTRON EXCITED AUGER ELECTRONS WITH A RETARDING-FIELD ANALYZER
    BRODERSEN, H
    PICKUTH, A
    LEGLER, W
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1987, 42 (09): : 935 - 942
  • [49] DESIGN OF A NEW RETARDING-FIELD ELECTRON SPECTROMETER FOR DEPTH-SELECTIVE CONVERSION ELECTRON MOSSBAUER-SPECTROSCOPY
    VANNOORT, HM
    VANGORKUM, AA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (06): : 587 - 591
  • [50] Angular-resolved elastic peak electron spectroscopy: experiment and Monte Carlo calculations
    Zemek, J
    Jiricek, P
    Werner, WSM
    Lesiak, B
    Jablonski, A
    SURFACE AND INTERFACE ANALYSIS, 2006, 38 (04) : 615 - 619