A rapid and accurate method for estimating the erythrocyte sedimentation rate using a hematocrit-corrected optical aggregation index

被引:11
|
作者
Higuchi, Makoto [1 ,2 ]
Watanabe, Nobuo [1 ]
机构
[1] Shibaura Inst Technol, Grad Sch Engn & Sci, Funct Control Syst Course, Saitama, Japan
[2] Nihon Kohden Corp, Ogino Mem Lab, Tokyo, Japan
来源
PLOS ONE | 2022年 / 17卷 / 07期
关键词
BLOOD-CELL AGGREGATION; SYSTEM; FIBRINOGEN; IMPEDANCE; MECHANISM;
D O I
10.1371/journal.pone.0270977
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Although both the erythrocyte sedimentation rate (ESR) and optically measured erythrocyte aggregation parameters are affected by the hematocrit, this interaction is not considered by the method used to estimate ESR that considers aggregation parameters. In this study, we investigated the relationship between the ESR obtained by the Westergren method and that obtained with an aggregation parameter, namely, the aggregation index (AI) of multiple hematocrit values and fibrinogen-spiked samples with an analysis time of 5-60 s, and attempted to develop a rapid and accurate ESR estimation method. The AIs obtained from 5- and 10-s optical measurements with a fixed hematocrit were highly correlated with the erythrocyte sedimentation velocity. Furthermore, the rate of the AI increase with an increasing hematocrit was not significantly affected by the fibrinogen concentration at these measurement times. On the basis of these results, we defined the hematocrit-corrected aggregation index (HAI). The exponential function of the HAI obtained from the 5-s measurement agreed well with the sedimentation velocity calculated to eliminate the effect of hindered settling, and the HAI and hematocrit could be used to calculate the time constant of the sedimentation curve with a linear regression equation. The ESR value at 1 h was calculated based on the modified Stokes' law and the HAI obtained from the 5-s measurement and showed an excellent correlation (R = 0.966) with the ESR value obtained by the Westergren method over a wide range of hematocrit and fibrinogen concentrations.
引用
收藏
页数:16
相关论文
共 26 条
  • [21] Accurate Modeling and Design of Graded-Index Fiber Probes for Optical Coherence Tomography Using the Beam Propagation Method
    Lorenser, D.
    Yang, X.
    Sampson, D. D.
    IEEE PHOTONICS JOURNAL, 2013, 5 (02):
  • [22] Accurate interchannel pitch control in graded-index circular-core polymer parallel optical waveguide using the Mosquito method
    Kinoshita, Ryota
    Suganuma, Daisuke
    Ishigure, Takaaki
    OPTICS EXPRESS, 2014, 22 (07): : 8426 - 8437
  • [23] USING FAST REPETITION RATE FLUOROMETRY TO ESTIMATE PSII ELECTRON FLUX PER UNIT VOLUME: A PURELY OPTICAL METHOD FOR ESTIMATING GPP BY PHYTOPLANKTON?
    Oxborough, Kevin
    Moore, Mark
    Suggett, David J.
    Geider, Richard
    EUROPEAN JOURNAL OF PHYCOLOGY, 2015, 50 : 34 - 34
  • [24] METHOD FOR ESTIMATING THE TOXICITY OF CHEMICALS TO ACTIVATED-SLUDGE .2. A RAPID-DETERMINATION AND APPLICATION OF OXYGEN-UPTAKE RATE BY USING OXYGEN-ELECTRODE
    MIHARA, Y
    FURUSAWA, N
    AKIBA, M
    IKEDA, S
    SAITO, K
    SHIROTO, N
    YOKOTA, K
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1991, 37 (03): : 179 - 184
  • [25] A rapid and accurate method for the quantitative estimation of natural polysaccharides and their fractions using high performance size exclusion chromatography coupled with multi-angle laser light scattering and refractive index detector
    Cheong, Kit-Leong
    Wu, Ding-Tao
    Zhao, Jing
    Li, Shao-Ping
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1400 : 98 - 106
  • [26] Assessment of the validity of the 28-joint disease activity score using erythrocyte sedimentation rate (DAS28-ESR) as a disease activity index of rheumatoid arthritis in the efficacy evaluation of 24-week treatment with tocilizumab: subanalysis of the SATORI study
    Nishimoto, Norihiro
    Takagi, Nobuhiro
    MODERN RHEUMATOLOGY, 2010, 20 (06) : 539 - 547