A rapid and accurate method for estimating the erythrocyte sedimentation rate using a hematocrit-corrected optical aggregation index

被引:11
|
作者
Higuchi, Makoto [1 ,2 ]
Watanabe, Nobuo [1 ]
机构
[1] Shibaura Inst Technol, Grad Sch Engn & Sci, Funct Control Syst Course, Saitama, Japan
[2] Nihon Kohden Corp, Ogino Mem Lab, Tokyo, Japan
来源
PLOS ONE | 2022年 / 17卷 / 07期
关键词
BLOOD-CELL AGGREGATION; SYSTEM; FIBRINOGEN; IMPEDANCE; MECHANISM;
D O I
10.1371/journal.pone.0270977
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Although both the erythrocyte sedimentation rate (ESR) and optically measured erythrocyte aggregation parameters are affected by the hematocrit, this interaction is not considered by the method used to estimate ESR that considers aggregation parameters. In this study, we investigated the relationship between the ESR obtained by the Westergren method and that obtained with an aggregation parameter, namely, the aggregation index (AI) of multiple hematocrit values and fibrinogen-spiked samples with an analysis time of 5-60 s, and attempted to develop a rapid and accurate ESR estimation method. The AIs obtained from 5- and 10-s optical measurements with a fixed hematocrit were highly correlated with the erythrocyte sedimentation velocity. Furthermore, the rate of the AI increase with an increasing hematocrit was not significantly affected by the fibrinogen concentration at these measurement times. On the basis of these results, we defined the hematocrit-corrected aggregation index (HAI). The exponential function of the HAI obtained from the 5-s measurement agreed well with the sedimentation velocity calculated to eliminate the effect of hindered settling, and the HAI and hematocrit could be used to calculate the time constant of the sedimentation curve with a linear regression equation. The ESR value at 1 h was calculated based on the modified Stokes' law and the HAI obtained from the 5-s measurement and showed an excellent correlation (R = 0.966) with the ESR value obtained by the Westergren method over a wide range of hematocrit and fibrinogen concentrations.
引用
收藏
页数:16
相关论文
共 26 条
  • [1] Determination of the erythrocyte sedimentation rate using the hematocrit-corrected aggregation index and mean corpuscular volume
    Higuchi, Makoto
    Watanabe, Nobuo
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2023, 37 (06)
  • [2] The hematocrit-corrected erythrocyte sedimentation rate can be useful in diagnosing inflammation in hemodialysis patients
    Borawski, J
    Mysliwiec, M
    NEPHRON, 2001, 89 (04): : 381 - 383
  • [3] Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
    Hashemi, Reza
    Majidi, Alireza
    Motamed, Hassan
    Amini, Afshin
    Najari, Fares
    Tabatabaey, Ali
    EMERGENCY, 2015, 3 (02): : 50 - 53
  • [4] QUICK MEASUREMENT OF HEMATOCRIT AND ERYTHROCYTE SEDIMENTATION-RATE BY MEANS OF A DENSITY TRACKING METHOD
    SCHNEDITZ, D
    KENNER, T
    GALLASCH, E
    RAINER, F
    BLUT, 1987, 55 (03): : 153 - 163
  • [5] A SIMPLE RELIABLE MICRO-METHOD OF ESTIMATING ERYTHROCYTE SEDIMENTATION RATE
    PHILLIPS, J
    PRACTITIONER, 1965, 194 (1163) : 672 - &
  • [6] Length of erythrocyte sedimentation rate (ESR) adjusted for the hematocrit:: Reference values for the TEST 1™ method
    Giavarina, D
    Capuzzo, S
    Pizzolato, U
    Soffiati, G
    CLINICAL LABORATORY, 2006, 52 (5-6) : 241 - 245
  • [7] Monitoring of the aggregation phase of erythrocyte sedimentation rate by impedance method on micrometric scale
    Tvarozek, V
    Krausko, G
    Zahorec, R
    Novotny, I
    Rehacek, V
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 387 - 389
  • [8] Effect of Erythrocyte Aggregation on Hematocrit Measurement Using Spectral-Domain Optical Coherence Tomography
    Xu, Xiangqun
    Yu, Lingfeng
    Chen, Zhongping
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (12) : 2753 - 2758
  • [9] CAUSE OF ANOMALOUS RESULTS IN THE ERYTHROCYTE SEDIMENTATION RATE USING WINTROBES METHOD
    SHANNON, FT
    BYWATERS, EGL
    BRITISH MEDICAL JOURNAL, 1957, 2 (DEC14): : 1405 - 1409
  • [10] DESCRIPTION AND EVALUATION OF A NEW METHOD FOR THE RAPID-DETERMINATION OF THE ERYTHROCYTE SEDIMENTATION-RATE
    WAGNER, H
    MIRZAIE, M
    KURZ, H
    MEDIZINISCHE KLINIK, 1989, 84 (01) : 15 - 22