Biomechanical efficacy of four different dual screws fixations in treatment of talus neck fracture: a three-dimensional finite element analysis

被引:14
|
作者
Fan, Zhengrui [1 ,2 ]
Ma, Jianxiong [1 ,2 ]
Chen, Jian [1 ,2 ]
Yang, Baocheng [1 ,2 ]
Wang, Ying [1 ,2 ]
Bai, Haohao [1 ,2 ]
Sun, Lei [1 ,2 ]
Wang, Yan [1 ,2 ]
Lu, Bin [1 ,2 ]
Dong, Ben-chao [1 ,2 ]
Tian, Aixian [1 ,2 ]
Ma, Xinlong [1 ,2 ,3 ]
机构
[1] Tianjin Med Univ, Biomech Labs Orthopaed Inst, Clin Coll Orthoped, Tianjin 300050, Peoples R China
[2] Tianjin Univ, Tianjin Hosp, Tianjin 300211, Peoples R China
[3] Tianjin Hosp, Dept Orthoped, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Talus neck fracture; Finite element analysis; Three-dimensional reconstruction; Internal fixation; TALAR NECK; ANKLE; COMPLICATIONS; MANAGEMENT; LIGAMENTS;
D O I
10.1186/s13018-020-1560-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Current there are different screws fixation methods used for fixation of the talar neck fracture. However, the best method of screws internal fixation is still controversial. Few relevant studies have focused on this issue, especially by finite element analysis. The purpose of this study was to explore the mechanical stability of dual screws internal fixation methods with different approaches and the best biomechanical environment of the fracture section, so as to provide reliable mechanical evidence for the selection of clinical internal fixation. Methods The computed tomography (CT) image of the healthy adult male ankle joint was used for three-dimensional reconstruction of the ankle model. Talus neck fracture and screws were constructed by computer-aided design (CAD). Then, 3D model of talar neck fracture which fixed with antero-posterior (AP) parallel dual screws, antero-posterior (AP) cross dual screws, postero-anterior (PA) parallel dual screws, and postero-anterior (PA) cross dual screws were simulated. Finally, under the condition of 2400N vertical load, finite element analysis (FEA) were carried out to compare the outcome of the four different internal fixation methods. The results of Von Mises stress, displacement of four groups which contain talus fracture fragments and screws internal fixations were analyzed. Results Compared with the other three groups, postero-anterior (PA) parallel dual screws had better results in the stress peak, stress distribution, and displacement of talus and internal fixation. Conclusions To sum up, the Von Mises stress of fracture section was the smallest, the stress distribution of screws were the most scattered, and the peak value was the smallest in posterior to anterior parallel double screws fixation, which was obviously better than that in the other three groups. When using screws internal fixation, the method of posterior to anterior screws fixation is better than that of anterior to posterior screws fixation, and the peak value and stress distribution of parallel double screws fixation is better than that of cross double screws fixation. Thus, for the talar neck fracture, the use of posterior to anterior parallel double screws fixation is recommended in clinical surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A Three-Dimensional Finite Element Analysis of the Stress Intensity Factors for Different Fracture Modes of Homogeneous Bimaterial
    Hedia, Hassan S.
    Aldousari, S. M.
    Fouda, N.
    MATERIALS TESTING, 2010, 52 (03) : 166 - 173
  • [32] Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis
    Ozan, Oguz
    Kurtulmus-Yilmaz, Sevcan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 64 - 71
  • [33] Biomechanical Effect of Platform Switching in Implant Dentistry: A Three-Dimensional Finite Element Analysis
    Chang, Chih-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (02) : 295 - 304
  • [34] Three-dimensional finite element analysis of the pelvic organ prolapse: A parametric biomechanical modeling
    Babayi, Masumeh
    Azghani, Mahmood-Reza
    Hajebrahimi, Sakineh
    Berghmans, Bary
    NEUROUROLOGY AND URODYNAMICS, 2019, 38 (02) : 591 - 598
  • [35] Biomechanical Factors Associated with Mandibular Cantilevers: Analysis with Three-Dimensional Finite Element Models
    Gonda, Tomoya
    Yasuda, Daiisa
    Ikebe, Kazunori
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : E275 - E282
  • [36] Biomechanical Effects of a Maxillary Implant in the Augmented Sinus: A Three-Dimensional Finite Element Analysis
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Ko, Ching-Chang
    Hsu, Jui-Ting
    Chen, Chern-Chin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (03) : 455 - 462
  • [37] Effects of Occlusal Scheme on All-on-Four Abutments, Screws, and Prostheses: A Three-Dimensional Finite Element Study
    Turker, Nurullah
    Alkis, Humeyra Tercanli
    Sadowsky, Steven J.
    Buyukkaplan, Ulviye Sebnem
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (01) : 18 - 24
  • [38] Three-dimensional finite element analysis of intramedullary nail with different materials in the treatment of intertrochanteric fractures
    Wang, Chenyan
    Li, Xiaona
    Chen, Weiyi
    Wang, Changjiang
    Guo, Yuan
    Guo, Hongmei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (04): : 705 - 712
  • [39] Three-Dimensional Finite Element Analysis Used to Compare Six Different Methods of Syndesmosis Fixation with 3.5-or 4.5-mm Titanium Screws A Biomechanical Study
    Er, Mehmet Serhan
    Verim, Ozgur
    Altinel, Levent
    Tasgetiren, Suleyman
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2013, 103 (03) : 174 - 180
  • [40] Correction to: Comparison of three different internal fixation implants in treatment of femoral neck fracture—a finite element analysis
    Jia Li
    Zhe Zhao
    Pengbin Yin
    Licheng Zhang
    Peifu Tang
    Journal of Orthopaedic Surgery and Research, 14