PurposeDose painting (DP) is a radiation therapy (RT) strategy for patients with heterogeneous tumors delivering higher dose to radiation resistant regions and less to sensitive ones, thus aiming to maximize tumor control with limited side effects. The success of DP treatments is influenced by the spatial accuracy in dose delivery. Adaptive RT (ART) workflows can reduce the overall geometric dose delivery uncertainty. The purpose of this study is to dosimetrically compare ART and non-adaptive conventional RT workflows for delivery of DP prescriptions in the treatment of prostate cancer (PCa). Materials and methodsWe performed a planning and treatment simulation study of four study arms. Adaptive and conventional workflows were tested in combination with DP and Homogeneous dose. We used image data from 5 PCa patients that had been treated on the Elekta Unity MR linac; the patients had been imaged in treatment position before each treatment fraction (7 in total). The local radiation sensitivity from apparent diffusion coefficient maps of 15 high-risk PCa patients was modelled in a previous study. these maps were used as input for optimization of DP plans aiming for maximization of tumor control probability (TCP) under rectum dose constraints. A range of prostate doses were planned for the homogeneous arms. Adaptive plans were replanned based on the anatomy-of-the-day, whereas conventional plans were planned using a pre-treatment image and subsequently recalculated on the anatomy-of-the-day. The dose from 7 fractions was accumulated using dose mapping. The endpoints studied were the TCP and dose-volume histogram metrics for organs at risk. ResultsAccumulated DP doses (adaptive and conventional) resulted in high TCP, between 96-99%. The largest difference between adaptive and conventional DP was 2.6 percentage points (in favor of adaptive DP). An analysis of the dose per fraction revealed substantial target misses for one patient in the conventional workflow that-if systematic-could jeopardize the TCP. Compared to homogeneous prescriptions with equal mean prostate dose, DP resulted in slightly higher TCP. ConclusionCompared to homogeneous dose, DP maintains or marginally increases the TCP. Adaptive DP workflows could avoid target misses compared to conventional workflows.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Prostate IMRT dose escalation with urethra sparing: Dose painting with IGRT
    Zhang, M.
    Moiseenko, V.
    Liu, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 1986 - 1986
  • [22] Phase I Trial on Adaptive Dose Painting by Numbers for Head and Neck Cancer: What is the Maximum Tolerated Dose?
    Madani, I.
    Duprez, F.
    De Gersem, W.
    Coghe, M.
    De Neve, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S82 - S82
  • [23] Painting the genetic landscape of prostate cancer
    Mina Razzak
    Nature Reviews Urology, 2012, 9 (7) : 352 - 352
  • [24] Dosimetric and Radiobiological Evaluation of Multiparametric MRI-Guided Dose Painting in Radiotherapy of Prostate Cancer
    Tavakoli, M.
    Abedi, I.
    Jabbari, K.
    Amouheidari, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2912 - 2912
  • [25] The feasibility of a dose painting procedure to treat prostate cancer based on mpMR images and hierarchical clustering
    Seyed Masoud Rezaeijo
    Bijan Hashemi
    Bahram Mofid
    Mohsen Bakhshandeh
    Arash Mahdavi
    Mohammad Saber Hashemi
    Radiation Oncology, 16
  • [26] Dose painting in prostate cancer with simultaneous 11C-Choline PET and Multiparametric MR
    Marino, E.
    Pena, G.
    Mugneco, A.
    Aguero, H.
    Alvarez, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S430 - S431
  • [27] The feasibility of a dose painting procedure to treat prostate cancer based on mpMR images and hierarchical clustering
    Rezaeijo, Seyed Masoud
    Hashemi, Bijan
    Mofid, Bahram
    Bakhshandeh, Mohsen
    Mahdavi, Arash
    Hashemi, Mohammad Saber
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [28] Adaptive PET-Based Dose Painting with Tomotherapy
    Darwish, N.
    Mackie, T.
    Thomadsen, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 196 - 197
  • [29] Randomised escalation trial with adaptive dose painting by numbers for head and neck cancer: interim analysis
    Duprez, F.
    Berwouts, D.
    Boterberg, T.
    De Gersem, W.
    Olteanu, L.
    Vercauteren, T.
    De Neve, W.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S204 - S205
  • [30] Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer
    Olteanu, Luiza A. M.
    Madani, Indira
    De Neve, Wilfried
    Vercauteren, Tom
    De Gersem, Werner
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 696 - 703