Evaluation of optical thickness and refractive index of a layered sample by low coherence optical tomography

被引:0
|
作者
Pratima, S [1 ]
Shubhada, K [1 ]
Sanjay, G [1 ]
机构
[1] SGS Inst Technol & Sci, Dept Appl Phys, Indore 452003, India
关键词
optical low coherence reflectometry; fibre optic coupler; signal-to-noise ratio; optical thickness; coupled mode approach; layered structure;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Following coupled mode approach, we report ab initio calculations of the signal intensity obtainable at the output end of a fibre optic coupler in a standard OCT technique and the results have been verified experimentally. The calculated intensity output varies periodically with respect to the path length difference between the sample and the reference ann and represent the interference signal, which sustains within the coherence length of the source. In the experimental set up, we have used 670 nm semiconductor diode laser possessing coherence length of 60 micron as a source. We have used a sample consisting of thin layer of glass plate and mirror. Reference mirror of 80% reflectivity was chosen. The output from the coupler was read on the Digital storage oscilloscope. A comparison of the theoretical plot of signal amplitude as a function of reference mirror position with the trace of the signal obtained on DSO exhibits good matching. The refractive index of the glass plate as calculated experimentally was 1.50 +/- .0125 which agrees well with the standard value. The experimental setup can enable one to determine the refractive index as well as optical thickness of any thin film simultaneously. The signal-to-noise ratio was found to be similar to 20dB.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 50 条
  • [41] Comment on: Evaluation of choroidal thickness in amblyopia using optical coherence tomography
    De Bernardo, Maddalena
    Gioia, Marco
    Capasso, Luigi
    Rosa, Nicola
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : NP324 - NP324
  • [42] Evaluation of Choroidal Thickness in Ankylosing Spondylitis Using Optical Coherence Tomography
    Kola, Mehmet
    Kalkisim, Ahmet
    Karkucak, Murat
    Turk, Adem
    Capkin, Erhan
    Can, Ipek
    Serdar, Omer Faruk
    Mollamehmetoglu, Suleyman
    Ayar, Ahmet
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2014, 22 (06) : 434 - 438
  • [43] Evaluation of Choroidal Thickness in Ankylosing Spondylitis Using Optical Coherence Tomography
    Yolcu, Umit
    Ilhan, Abdullah
    Gundogan, Fatih C.
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2015, 23 (06) : 464 - 464
  • [44] Evaluation of Macular Thickness by Optical Coherence Tomography After Phacoemulsification Surgery
    Tetikoglu, Mehmet
    Un, Yasemin
    Tunc, Yavuz
    Yilmaz, Tolga
    Ozturk, Muzaffer
    Cinhuseyinoglu, Mehmet Necdet
    Elcioglu, Mustafa Nuri
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (02): : 88 - 91
  • [45] Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography
    Knüttel, A
    Boehlau-Godau, M
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (01) : 83 - 92
  • [46] DETERMINATION OF THE REFRACTIVE-INDEX OF HIGHLY SCATTERING HUMAN TISSUE BY OPTICAL COHERENCE TOMOGRAPHY
    TEARNEY, GJ
    BREZINSKI, ME
    SOUTHERN, JF
    BOUMA, BE
    HEE, MR
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1995, 20 (21) : 2258 - 2260
  • [47] Estimation of Refractive Index for Biological Tissue Using Micro-Optical Coherence Tomography
    Tang, Hongying
    Liu, Xinyu
    Chen, Si
    Yu, Xiaojun
    Luo, Yuemei
    Wu, Junying
    Wang, Xianghong
    Liu, Linbo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1803 - 1809
  • [48] Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery
    Rahlves, M.
    Diaz, J. Diaz
    Thommes, J.
    Majdani, O.
    Roth, B.
    Ortmaier, T.
    Reithmeier, E.
    [J]. 2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [49] Matrix approach to quantitative refractive index analysis by Fourier domain optical coherence tomography
    Tomlins, Peter H.
    Wang, Ruikang K.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (08) : 1897 - 1907
  • [50] Conjunctival Thickness Measured by Optical Coherence Tomography
    Zhang, Xing-Ru
    Zhang, Zhen-Yong
    Hoffman, Matthew R.
    [J]. OPHTHALMOLOGY, 2013, 120 (06) : 1305 - 1305