The Effect of Magnesium-Incorporated Hydroxyapatite Coating on Titanium Implant Fixation in Ovariectomized Rats

被引:12
|
作者
Li, Xudong [1 ,2 ,3 ,4 ]
Li, Yunfeng [1 ,2 ]
Liao, Yunmao [1 ,2 ]
Li, Jihua [1 ,2 ]
Zhang, Li [1 ,2 ]
Hu, Jing [1 ,2 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp Stomatol, Dept Oral & Maxillofacial Surg, Chengdu 610041, Peoples R China
[3] Xiasha Hosp Hangzhou, Dent Clin, Hangzhou, Zhejiang, Peoples R China
[4] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Xiasha Hosp Dist, Hangzhou 310003, Zhejiang, Peoples R China
关键词
dental implants; hydroxyapatite; magnesium; osseointegration; osteoporosis; DIETARY MAGNESIUM; BONE RESPONSE; OSTEOPOROSIS; OSSEOINTEGRATION; METABOLISM; STRENGTH; ALLOY;
D O I
10.11607/jomi.2893
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study compared the effect of magnesium-incorporated hydroxyapatite (MgHA) coating with that of HA coating on implant fixation in ovariectomized (OVX) rats. Materials and Methods: Coatings of HA and MgHA (10 mol% Ca2+ replaced by Mg2+) were prepared on the surface of titanium substrates using the sol-gel dip-coating method, and powders of HA and MgHA were produced by the same method. The two kinds of materials were then characterized by scanning electron microscopy and x-ray diffraction. Twelve weeks after bilateral ovariectomy, 18 OVX rats received implants in the distal femora; half of the implants were HA-coated and the other half were MgHA-coated. After 12 weeks of healing, rats were selected randomly for histomorphometry, microcomputed tomography evaluation, and biomechanical testing. Results: Surface characterization analysis demonstrated that the addition of Mg did not dramatically change the surface topography or apatite patterns of the coating. Histomorphometry revealed higher bone-to-implant contact and bone area ratio for MgHA-coated implants than for HA-coated implants. Microcomputed tomographic evaluation revealed improved trabecular parameters and increased osseointegration for MgHA-coated implants. Biomechanical testing revealed that the MgHA coating increased the maximum push-out force and interfacial shear strength compared to the HA coating. Conclusion: Mg incorporated into an HA coating on titanium implants could improve the biologic fixation of implants in osteoporotic bone.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [31] Effect of Preoperative combined treatment with alendronate and calcitriol on fixation of hydroxyapatite-coated implants in ovariectomized rats
    Nakamura, Yoshinari
    Hayashi, Kazuo
    Abu-Ali, Samah
    Naito, Masatoshi
    Fotovati, Abbas
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04): : 824 - 832
  • [32] Fabrication and In vitro Bioactivity of Robust Hydroxyapatite Coating on Porous Titanium Implant
    Duan Mengna
    Wu Xiaofeng
    Yuan Long
    Zhang Zhiying
    Zhang Yan
    Zhou Yanmin
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2019, 35 (04) : 686 - 692
  • [33] Fabrication and In vitro Bioactivity of Robust Hydroxyapatite Coating on Porous Titanium Implant
    Mengna Duan
    Xiaofeng Wu
    Long Yuan
    Zhiying Zhang
    Yan Zhang
    Yanmin Zhou
    [J]. Chemical Research in Chinese Universities, 2019, 35 : 686 - 692
  • [34] Effect of a prostaglandin EP4 receptor agonist on early fixation of hydroxyapatite/titanium composite- and titanium-coated rough-surfaced implants in ovariectomized rats
    Hayashi, K.
    Fotovati, A.
    Abu Ali, S.
    Nakamura, Y.
    Inagaki, M.
    Naito, M.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (03) : 1202 - 1209
  • [35] A comparative study of zinc, magnesium, strontium-incorporated hydroxyapatite-coated titanium implants for osseointegration of osteopenic rats
    Tao, Zhou-Shan
    Zhou, Wan-Shu
    He, Xing-Wen
    Liu, Wei
    Bai, Bing-Li
    Zhou, Qiang
    Huang, Zheng-Liang
    Tu, Kai-kai
    Li, Hang
    Sun, Tao
    Lv, Yang-Xun
    Cui, Wei
    Yang, Lei
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 226 - 232
  • [36] Effect of hydroxyapatite concentration and electrophoretic deposition (EPD) parameter process on hydroxyapatite/chitosan coating quality for porous titanium as orthopedic implant
    Annur, Dhyah
    Hasanah, Labibah Nur
    Kartika, Ika
    Supriadi, Sugeng
    Suharno, Bambang
    [J]. CANADIAN METALLURGICAL QUARTERLY, 2024,
  • [37] HYDROXYAPATITE CERAMIC COATING FOR BONE IMPLANT FIXATION - MECHANICAL AND HISTOLOGICAL STUDIES IN DOGS
    SOBALLE, K
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 : R1 - +
  • [38] Novel hydroxyapatite coating on new porous titanium and titanium-HDPE composite for hip implant
    Xie, Jianhui
    Luan, Ben Li
    Wang, Jianfeng
    Liu, Xing Yang
    Rorabeck, Cecil
    Bourne, Robert
    [J]. SURFACE & COATINGS TECHNOLOGY, 2008, 202 (13): : 2960 - 2968
  • [39] Biomimetic CaP coating incorporated with parathyroid hormone improves the osseointegration of titanium implant
    Xiaohua Yu
    Liping Wang
    Xi Jiang
    David Rowe
    Mei Wei
    [J]. Journal of Materials Science: Materials in Medicine, 2012, 23 : 2177 - 2186
  • [40] Biomimetic CaP coating incorporated with parathyroid hormone improves the osseointegration of titanium implant
    Yu, Xiaohua
    Wang, Liping
    Jiang, Xi
    Rowe, David
    Wei, Mei
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (09) : 2177 - 2186