Modeling of Electromagnetic Fields Occurring at Intersection of Traction Networks and Overhead Power Supply Lines

被引:0
|
作者
Buyakova, Natalya [1 ]
Kryukov, Andrey [2 ]
Seredkin, Dmitry [2 ]
机构
[1] Angarsk State Tech Univ, Chair Power Supply Ind Enterprises, Angarsk, Russia
[2] Irkutsk State Transport Univ, Chair Transport Power Syst, Irkutsk, Russia
关键词
electromagnetic safety; power supply lines; electrified railroads; electromagnetic field; modeling;
D O I
10.1109/icieam48468.2020.9111873
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Traction networks (TN) 25 kV generate higher electromagnetic fields (EMF) with frequency 50 Hz, the strengths of which at a standardized height of 1.8 m, as a rule, do not exceed the permissible norms for electrical personnel. In places where railroads routes intersect with high voltage overhead power supply lines (OPL), the interference of fields, generated by the traction network and OPL, occurs. This can lead to an increase in strengths and a complication of the EMF spatial structures. The article presents a methodology for determining the strengths created at intersections, and modelling results performed for typical situations when a TS of 25 or 2x25 kV is intersected by an overhead power line of 220 kV at an angle of 90 degrees. The algorithm for calculating the resulting EMF strengths includes the following steps: calculation of TN and OPL modes in phase coordinates, the results of which determine the potentials and currents of all wires; the calculation of the vertical and horizontal components of the EMF strengths; calculation of amplitude values of strengths at the intersection point taking into account possible elliptical polarization. The modelling results show that the maxima of the amplitudes of the magnetic field strength at the points of intersection by the traction network of 25 kV and OPL of 220 kV reach 83 A/m. A similar parameter for the electric field equals to 5.4 kV/m. For a 2x25 kV traction network, these values are reduced to 32 A/m and 4 kV/m, respectively. This work was financially supported by the grant "Improving the quality of electric energy and electromagnetic safety in railway power supply systems equipped with Smart Grid devices by applying methods and means of mathematical modeling based on phase coordinates".
引用
收藏
页数:6
相关论文
共 50 条
  • [21] THE ELECTROMAGNETIC INFLUENCE OF AC TRACTION NETWORKS ON METAL SERVICE LINES
    KOTELNIKOV, AV
    KOSAREV, AB
    ELECTRICAL TECHNOLOGY, 1992, (03): : 149 - 167
  • [22] One-dimensional parallel forward modeling for geophysical electromagnetic fields excited by sagging overhead transmission lines
    Zhu, Siwei
    Li, Jianhui
    Hu, Xiangyun
    Yi, Yukai
    COMPUTERS & GEOSCIENCES, 2024, 185
  • [23] Computer Simulation of Magnetic Fields Caused by Overhead Power Lines
    Kadmiri, K.
    Baghzouz, Y.
    Simulation Councils Proceedings Series, 1994, 27 (02):
  • [24] Review of Structural Solutions in High-Voltage Overhead Power Lines and Possibilities of Reducing Emission of Electromagnetic Fields
    Wroblewski, Zbigniew
    Sztafrowski, Dariusz
    Gumiela, Jacek
    ANALYSIS AND SIMULATION OF ELECTRICAL AND COMPUTER SYSTEMS, 2018, 452 : 173 - 184
  • [25] A review on residential exposure to electromagnetic fields from overhead power lines: electrification as a health burden in rural communities
    Rathebe, Phoka C.
    Modisane, Dineo S.
    Rampedi, Maite B.
    Biddesay-Manilal, S.
    Mbonane, Thokozani P.
    2019 OPEN INNOVATIONS CONFERENCE (OI), 2019, : 219 - 221
  • [26] Lightning electromagnetic fields modeling using an indirect hybrid method-interaction with an overhead power line
    Laboratoire de Modelisation des Systemes Electrotechniques et Systemes Experts, U.S.T.O. Mb, B.P. 1505, El M'Naouar, Oran 31000, Algeria
    不详
    不详
    J. Appl. Sci., 2006, 8 (1774-1784):
  • [27] Consideration of the influence of supports in modeling the electromagnetic fields of 25 kV traction networks under emergency conditions
    Suslov, Konstantin
    Kryukov, Andrey
    Voronina, Ekaterina
    Ilyushin, Pavel
    Global Energy Interconnection, 2024, 7 (04) : 528 - 540
  • [28] Consideration of the influence of supports in modeling the electromagnetic fields of 25 kV traction networks under emergency conditions
    Suslov, Konstantin
    Kryukov, Andrey
    Voronina, Ekaterina
    Ilyushin, Pavel
    GLOBAL ENERGY INTERCONNECTION-CHINA, 2024, 7 (04): : 528 - 540
  • [29] Consideration of the influence of supports in modeling the electromagnetic fields of 25 kV traction networks under emergency conditions
    Konstantin Suslov
    Andrey Kryukov
    Ekaterina Voronina
    Pavel Ilyushin
    GlobalEnergyInterconnection, 2024, 7 (04) : 528 - 540
  • [30] Interruptions of the power supply in 1150 kV overhead power lines during thunderstorms
    Larionov, VP
    Korolev, AV
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (02): : 78 - 83