Amperometric biosensor based on D-aminoacid oxidase for the R-perindopril assay

被引:21
|
作者
van Staden, AF [1 ]
Stefan, RI
Aboul-Enein, HY
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
[2] King Faisal Specialist Hosp & Res Ctr, Bioanalyt & Drug Dev Lab, Biol & Med Res Dept MBC03, Riyadh 11211, Saudi Arabia
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 367卷 / 02期
关键词
D O I
10.1007/s002160051620
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new amperometric biosensor based on D-aminoacid oxidase is described for the assay of R-perindopril. R-perindopril can be determined in the 400-20 nmol/L concentration range; the detection limit is 10 nmol/L. The selectivity was checked with S-perindopril, D- and L-proline, and polyvinylpyrrolidone. The main interfering species was D-proline. An automated system for the assay of R-perindopril based on the concept of flow injection with an amperometric biosensor (based on D-aminoacid oxidase) as detector is also described. The system is suitable for the on-line monitoring of R-perindopril at a sampling rate of 72 samples/h, in the Linear range: 100 nmol/L -20 nmol/L with an RSD better than 0.09% (n = 10).
引用
收藏
页码:178 / 180
页数:3
相关论文
共 50 条
  • [41] CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION
    AMINE, A
    ALAFANDY, M
    KAUFFMANN, JM
    PEKLI, MN
    ANALYTICAL CHEMISTRY, 1995, 67 (17) : 2822 - 2827
  • [42] Ethanol amperometric biosensor based on an alcohol oxidase graphite-polymer biocomposite
    Morales, A
    Cespedes, F
    Martinez-Fabregas, E
    Alegret, S
    ELECTROCHIMICA ACTA, 1998, 43 (23) : 3575 - 3579
  • [43] Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction
    Zhang, Juanjuan
    Wang, Chengyan
    Chen, Shihong
    Yuan, Dehua
    Zhong, Xia
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 52 (03) : 134 - 140
  • [44] An Amperometric Oxalate Biosensor Based on Polypropylene Tip Bound Sorghum Oxalate Oxidase
    Yadav, Sandeep
    Devi, Rooma
    Pundir, C. S.
    SENSOR LETTERS, 2011, 9 (05) : 1661 - 1665
  • [45] AN AMPEROMETRIC NADH BIOSENSOR BASED ON NADH OXIDASE FROM THERMUS-AQUATICUS
    COMPAGNONE, D
    MCNEIL, CJ
    ATHEY, D
    DIILIO, C
    GUILBAULT, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 1995, 17 (05) : 472 - 476
  • [46] An improved amperometric creatinine biosensor based on nanoparticles of creatininase, creatinase and sarcosine oxidase
    Kumar, Parveen
    Jaiwal, Ranjana
    Pundir, C. S.
    ANALYTICAL BIOCHEMISTRY, 2017, 537 : 41 - 49
  • [47] A biosensor system for chlorophenols using chloroperoxidase and a glucose oxidase based amperometric electrode
    Saby, C
    Luong, JHT
    ELECTROANALYSIS, 1998, 10 (01) : 7 - 11
  • [48] A Biosensor System for Chlorophenols Using Chloroperoxidase and a Glucose Oxidase Based Amperometric Electrode
    Saby, C.
    Luong, J. H. T.
    Electroanalysis, 10 (01):
  • [49] An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase
    Pundir, C. S.
    Narang, Jagriti
    Chauhan, Nidhi
    Sharma, Preety
    Sharma, Renu
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2012, 136 (04) : 633 - 640
  • [50] ESTIMATION OF SEVERAL ANTIDEPRESSANTS USING AN AMPEROMETRIC BIOSENSOR BASED ON IMMOBILIZED MONOAMINE OXIDASE
    Medyantseva, E. P.
    Varlamova, R. M.
    Gimaletdinova, D. A.
    Fattakhova, A. N.
    Budnikov, G. K.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2007, 41 (06) : 341 - 344