Identification and quantification of glutathione and phytochelatins from Chlorella vulgaris by RP-HPLC ESI-MS/MS and oxygen-free extraction

被引:28
|
作者
Simmons, Denina B. D. [2 ]
Hayward, Allison R. [2 ]
Hutchinson, Thomas C. [3 ]
Emery, R. J. Neil [1 ]
机构
[1] Trent Univ, Dept Biol, Peterborough, ON K9J 7B8, Canada
[2] Trent Univ, Environm & Life Sci Grad Program, Peterborough, ON K9J 7B8, Canada
[3] Trent Univ, Environm & Resource Studies Program, Peterborough, ON K9J 7B8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Phytochelatins; Chlorella vulgaris; Auto-oxidation; HPLC-MS; Internal standard; ESI-MS/MS; METAL-BINDING PEPTIDES; SILENE-VULGARIS; CADMIUM; PLANTS; HYPERACCUMULATOR; DETOXIFICATION; TRANSPORT; OXIDATION; EXPOSURE; CULTURES;
D O I
10.1007/s00216-009-3016-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Phytochelatins are short, cysteine-containing, detoxification peptides produced by plants, algae, and fungi in response to heavy metal exposure. These peptides auto-oxidize easily. Current extraction protocols do not adequately address losses of phytochelatins because of their oxidation and the use of indirect methods for quantification. Method enhancements include the use of an argon environment during extraction to reduce auto-oxidation, the use of glycine-(13)C2-labeled glutathione as an internal standard, and an electrospray ionization source with a triple quadrupole mass spectrometer as a detector. The method-detection limits were 0.081 mu M for glutathione, 0.440 mu M for phytochelatin 2, and 0.120 mu M for phytochelatin 3. These detection limits were comparable to similar studies and were not compromised incorporating these adjustments. The use of a labeled internal standard and an inert gaseous environment during sample preparation greatly improved calibration linearity and sensitivity. Furthermore, phytochelatin degradation was significantly reduced and more accurately tracked. Previous studies involving phytochelatin analyses have likely been subject to higher variability caused by this propensity for phytochelatins to degrade rapidly in air. The method adjustments were simple and cost-effective and allowed phytochelatin analyses to be performed for hours at a time with minimal auto-oxidation.
引用
收藏
页码:809 / 817
页数:9
相关论文
共 50 条
  • [41] Identification and Quantification of Steroidal Alkaloids from Wild Tuber-Bearing Solanum Species by HPLC and LC-ESI-MS
    Melanie Distl
    Michael Wink
    Potato Research, 2009, 52 : 79 - 104
  • [42] Quantification and identification of bioactive metabolites from Kalopanacis Cortex by HPLC with evaporative light scattering detection and ESI quadrupole TOF MS
    Liao, Lijuan
    Won, Tae Hyung
    Kim, Young Ho
    Shin, Jongheon
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (05) : 505 - 514
  • [43] Identification and Quantification of Steroidal Alkaloids from Wild Tuber-Bearing Solanum Species by HPLC and LC-ESI-MS
    Distl, Melanie
    Wink, Michael
    POTATO RESEARCH, 2009, 52 (01) : 79 - 104
  • [44] Effect of ultrasound treatment on the extraction of antioxidants from Ardisia compressa Kunth fruits and identification of phytochemicals by HPLC-ESI-MS
    Yolanda Vazquez-Sanchez, Alma
    Aguilar-Zarate, Pedro
    Beatriz Muniz-Marquez, Diana
    Enrique Wong-Paz, Jorge
    Rojas, Romeo
    Alberto Ascacio-Valdes, Juan
    Martinez-Avila, Guillermo Cristian G.
    HELIYON, 2019, 5 (12)
  • [45] Optimization of Microwave-Assisted Extraction of Anthocyanins from Mulberry and Identification of Anthocyanins in Extract Using HPLC-ESI-MS
    Zou, Tangbin
    Wang, Dongliang
    Guo, Honghui
    Zhu, Yanna
    Luo, Xiaoqin
    Liu, Fengqiong
    Ling, Wenhua
    JOURNAL OF FOOD SCIENCE, 2012, 77 (01) : C46 - C50
  • [46] Optimization of ultrasound-assisted extraction of gardenia fruit oil with bioactive components and their identification and quantification by HPLC-DAD/ESI-MS2
    Cai, Xiaoshuang
    Zhang, Rui
    Guo, Ying
    He, Jingren
    Li, Shuyi
    Zhu, Zhenzhou
    Liu, Gang
    Liu, Zhiwei
    Yang, Jun
    FOOD & FUNCTION, 2015, 6 (07) : 2194 - 2204
  • [47] A Stability Indicating Method Development and Validation for Separation of Process Related Impurities and Characterization of Unknown Impurities of Tyrosine Kinase Inhibitor Ibrutinib Using QbD Approach by RP-HPLC, NMR Spectroscopy and ESI-MS
    Gopireddy, Raman Reddy
    Maruthapillai, Arthanareeswari
    Mahapatra, Sudarshan
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (09) : 830 - 846
  • [48] The New RP-HPLC Method for Simultaneous Quantification of Cinnarizine, its Five Specified Impurities, Two Degradation Products with Two Antioxidants and Confirmation of all by HPLC-ESI-MS in Different Pharmaceutical Drug Formulations
    Mhaske, Deepak Krishna
    Kumbhar, Arjun Shankar
    ANALYTICAL CHEMISTRY LETTERS, 2022, 12 (03) : 391 - 408
  • [49] Profiling of 3-Formyl rifamycin (3-FR) from sintered fixed dose combinations (SDC) of rifampicin and isoniazid by using RP-HPLC, LC-ESI-QTOF and UPLC/MS/MS
    Karanwad, Tukaram
    Jorvekar, Sachin B.
    Mandal, Santa
    Borkar, Roshan M.
    Banerjee, Subham
    MICROCHEMICAL JOURNAL, 2024, 197
  • [50] Development and validation of a RP-HPLC method for stability-indicating assay of gemifloxacin mesylate including identification of related substances by LC-ESI-MS/MS, 1H and 13C NMR spectroscopy
    Rao, R. Nageswara
    Naidu, Ch. Gangu
    Prasad, K. Guru
    Narasimha, R.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) : 1222 - 1229