Experimental study on ventilation performance of reefer container hold

被引:0
|
作者
Park, I. S. [1 ]
Park, S. M. [1 ]
Seol, S. S. [1 ]
Lee, D. J. [1 ]
机构
[1] Hyundai Heavy Ind Co Ltd, Ulsan 682792, South Korea
关键词
reefer container; ventilation; visualization;
D O I
10.1115/HT2005-72177
中图分类号
O414.1 [热力学];
学科分类号
摘要
The analysis of ventilation performance varying with the length and number of duct in scale-model of reefer container hold has studied experimentally. Most container ships have ventilation system of which ducts extended to the bottom for the purpose of efficient exhausting of condensing heat from refrigerator. However, the duct is so over-long which causes manufacturing troubles and costs higher. In this study, for the various types of duct, the flow visualizing test with smoke oil and normalized temperature rising analysis are performed. Keeping the notation of class for reefer container stowage, we concurrently saved the material and manufacturing costs. Finally, the ventilation performances of each system are compared with each other.
引用
收藏
页码:731 / 735
页数:5
相关论文
共 50 条
  • [31] Experimental study on the periodic pulsating ventilation by fluidic oscillator on pollutant dispersion and ventilation performance in enclosed environment
    Yu, Ziyang
    Gao, Huimin
    Wang, Haidong
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2024,
  • [32] Simulation study of Container Terminal performance
    Nam, KC
    Kwak, KS
    Yu, MS
    [J]. JOURNAL OF WATERWAY PORT COASTAL AND OCEAN ENGINEERING, 2002, 128 (03) : 126 - 132
  • [33] Study on the thermal performance of refrigerated container
    Cao, D.
    Gan, W.
    Han, H. D.
    Huang, C. M.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 901 - 905
  • [34] Simulation study on container terminal performance
    Zhou Peng-fei
    Guo Zi-jian
    Song Xiang-qun
    [J]. Proceedings of the 2006 International Conference on Management Science & Engineering (13th), Vols 1-3, 2006, : 177 - 182
  • [35] Impact of wind speed on ventilation performance within a container installed with photovoltaic inverter
    Talka, Ismo
    Kolhe, Mohan
    Hyttinen, Jarkko
    [J]. RENEWABLE ENERGY, 2017, 113 : 1480 - 1489
  • [36] PRACTICAL TESTS WITH R290 USED IN REEFER CONTAINER REFRIGERATION LEAKAGE TESTING
    Koenig, Holger
    Bararu, Marius
    Holtappels, Kai
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 845 - 852
  • [37] The characteristics of cargo temperature rising in reefer container under refrigeration-failure condition
    Kan, Ankang
    Wang, Tongzhou
    Zhu, Wenbing
    Cao, Dan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 123 : 1 - 8
  • [38] Efficiency Optimization of Multiple-Tap-Coil-Based IPT System for Reefer Container
    Xu, Yefei
    Yang, Huanyu
    Gu, Yundong
    Mai, Ruikun
    [J]. 2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 3163 - 3166
  • [39] An experimental and numerical study on the effect of air terminal layout on the performance of stratum ventilation
    Building Energy and Environmental Technology Research Unit, Division of Building Science and Technology, City University of Hong Kong, Hong Kong
    [J]. Build. Environ., (75-86):
  • [40] An experimental and numerical study on the effect of air terminal types on the performance of stratum ventilation
    Yao, Ting
    Lin, Zhang
    [J]. BUILDING AND ENVIRONMENT, 2014, 82 : 431 - 441