Effects of a Calcium Phosphate-Coated and Anodized Titanium Surface on Early Bone Response

被引:10
|
作者
Koh, Jung-Woo [1 ,2 ]
Kim, Young-Sung [3 ,4 ]
Yang, Jae-Ho [1 ,2 ]
Yeo, In-Sung [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Seoul 110749, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Seoul 110749, South Korea
[3] Univ Ulsan, Coll Med, Dept Periodontol, Seoul, South Korea
[4] Asan Med Ctr, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
calcium phosphate; dental implants; osseointegration; oxidation; surface properties; ACID-ETCHED IMPLANTS; HISTOMORPHOMETRIC EVALUATION; DENTAL IMPLANTS; IN-VITRO; HYDROXYAPATITE; OSSEOINTEGRATION; DIFFERENTIATION; PROLIFERATION; PERFORMANCE; COATINGS;
D O I
10.11607/jomi.2783
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the effectiveness of a calcium phosphate (CaPO4)-coated and anodized titanium surface in vitro and in vivo. Materials and Methods: A turned surface was employed as a negative control. A sandblasted/acid-etched surface and an anodized surface were used as positive controls, and a CaPO4-coated and anodized (CPA) surface was investigated as the experimental group. Surface characteristics were analyzed with field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy. In vitro osteoblastic differentiation was evaluated by alkaline phosphatase assay. In vivo bone response was analyzed using bone-to-implant contact (BIC) ratios and bone area (BA) of 2- and 4-week specimens obtained from six rabbits. Results: The means and standard deviations for average height deviation (Sa) and developed surface area ratio (S-dr) were 0.32 +/- 0.03 mu m and 3.6% +/- 1.5% for the turned group, 1.36 +/- 0.11 mu m and 56.7% +/- 16.1% for the sandblasted/acid-etched group, 0.68 +/- 0.02 mu m and 50.9% +/- 2.9% for the anodized group, and 0.67 +/- 0.11 mu m and 50.0% +/- 16.9% for the CPA group. There were no significant differences in alkaline phosphatase activity among the groups at 7 and 14 days. In the in vivo experiment, the CPA group exhibited a significantly higher BIC ratio than the turned group, and the anodized and CPA groups showed significantly higher BA values than the others after 2 weeks. At 4 weeks, there was no significance in either BIC ratios or BA values among the groups. Conclusion: A CaPO4 coating on an anodized surface may induce rapid osseointegration at the bone-implant interface and more bone formation near the implant surface.
引用
收藏
页码:790 / 797
页数:8
相关论文
共 50 条
  • [31] Electrolyte effects on the surface chemistry and cellular response of anodized titanium
    Ohtsu, Naofumi
    Kozuka, Taro
    Hirano, Mitsuhiro
    Arai, Hirofumi
    APPLIED SURFACE SCIENCE, 2015, 349 : 911 - 915
  • [32] Prospective Observational Study of the Early Loading of Nanostructured Calcium Phosphate-Coated Tapered Implants in the Mandible and Maxilla
    Kim, Young-Kyun
    Yun, Pil-Young
    Kim, Sung-Bum
    Ahn, Kyo-Jin
    Lee, Hyo-Jung
    Yi, Yang-Jin
    Kim, Su-Gwan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (05) : 695 - 703
  • [33] The effect of platelet-rich plasma on the bone healing around calcium phosphate-coated and non-coated oral implants in trabecular bone
    Nikolidakis, Dimitris
    Van Den Dolder, Juliette
    Wolke, Joop G. C.
    Stoelinga, Paul J. W.
    Jansen, John A.
    TISSUE ENGINEERING, 2006, 12 (09): : 2555 - 2563
  • [34] Bone Regeneration Related to Calcium Phosphate-Coated Implants in Osteoporotic Animal Models: A Meta-Analysis
    Alghamdi, Hamdan S.
    Junker, Rudiger
    Bronkhorst, Ewald M.
    Jansen, John A.
    TISSUE ENGINEERING PART B-REVIEWS, 2012, 18 (05) : 383 - 395
  • [35] Morphometric immunohistochemical examination of the inflammatory tissue reaction after implantation of calcium phosphate-coated titanium plates in rats
    Walschus, Uwe
    Hoene, Andreas
    Neumann, Hans-Georg
    Wilhelm, Lutz
    Lucke, Silke
    Luethen, Frank
    Rychly, Joachim
    Schlosser, Michael
    ACTA BIOMATERIALIA, 2009, 5 (02) : 776 - 784
  • [36] Improved osseointeraction of calcium phosphate-coated external fixation pins - Studies in calves
    Anderson, DE
    St-Jean, G
    Richardson, DC
    DeBowes, RM
    Roush, JK
    Lowry, SR
    Toll, PW
    Aberman, HM
    Van Sickle, DC
    Hoskinson, JJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (06): : 571 - 576
  • [37] A Pilot Histologic Comparison of Bone-to-Implant Contact Between Phosphate-Coated and Control Titanium Implants in the Canine Model
    Derksen, Richard B.
    Kontogiorgos, Elias D.
    Dechow, Paul C.
    Opperman, Lynne A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 203 - 210
  • [38] SCANNING ELECTRON-MICROSCOPY STUDIES OF CERAMIC LAYERS AND INTERFACIAL REGIONS FOR CALCIUM PHOSPHATE-COATED TITANIUM DENTAL IMPLANTS
    BRANTLEY, WA
    TUFEKCI, E
    MITCHELL, JC
    FOREMAN, DW
    MCGLUMPHY, EA
    CELLS AND MATERIALS, 1995, 5 (01): : 73 - 82
  • [39] Ectopic bone formation in titanium mesh loaded with bone morphogenetic protein and coated with calcium phosphate
    Vehof, JWM
    Mahmood, J
    Takita, H
    van't Hof, MA
    Kuboki, Y
    Spauwen, PHM
    Jansen, JA
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (02) : 434 - 443
  • [40] Delivery of fluorophores by calcium phosphate-coated nanoliposomes and interaction with Staphylococcus aureus biofilms
    Rivero Berti, Ignacio
    Dell' Arciprete, Maria Laura
    Laura Dittler, Maria
    Minan, Alejandro
    Lorenzo de Mele, Monica Fernandez
    Gonzalez, Monica
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2016, 142 : 214 - 222