Measurement and Sources of Lateral Tape Motion: A Review

被引:3
|
作者
Raeymaekers, Bart [1 ]
Talke, Frank E. [1 ]
机构
[1] Univ Calif San Diego, Ctr Magnet Recording Res, La Jolla, CA 92093 USA
来源
关键词
electromagnetic actuators; magnetic heads; magnetic recording; magnetic tape storage; magnetic tapes; CYLINDRICAL GUIDE SURFACE; POROUS FOIL BEARINGS; MAGNETIC-TAPE; EDGE CONTACT; MOVING-MEDIA; DRIVE; VIBRATION; TENSION; STABILITY; DENSITY;
D O I
10.1115/1.3002332
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The sources of lateral tape motion in a tape drive are reviewed. Currently used measurement methods and models for lateral tape motion are analyzed and compared. The effect of roller run-out, tape edge contact, and tape tension transients on lateral tape motion is discussed. A dual stage actuator tape head is investigated to improve track-following capability and increase the track density on a magnetic tape.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] LOCAL MEASUREMENT OF LATERAL MOTION IN ERYTHROCYTE-MEMBRANES BY PHOTOBLEACHING TECHNIQUE
    KAPITZA, HG
    SACKMANN, E
    BIOCHIMICA ET BIOPHYSICA ACTA, 1980, 595 (01) : 56 - 64
  • [42] Measurement of magnetic tape abrasivity by interchanging tape thickness
    Rogers, Alan E.E.
    Hinteregger, Hans F.
    S T L E Tribology Transactions, 1993, 36 (01): : 139 - 143
  • [43] Precise Doppler shift measurement method based on motion radiation sources
    Du, Baoqiang
    Li, Songlin
    Sun, Xiyan
    MEASUREMENT, 2019, 136 : 275 - 281
  • [44] EXPERIMENTAL MODEL FOR SIMULATING MOTION OF MAGNETIC-TAPE IN A TAPE DRIVE
    FRASER, HR
    HAUKE, FE
    LAMMERS, GB
    WISE, TC
    IEEE TRANSACTIONS ON MAGNETICS, 1974, MA10 (03) : 892 - 894
  • [45] Sources of Error in HDRI for Luminance Measurement: A Review of the Literature
    Safranek, Sarah
    Davis, Robert G.
    LEUKOS, 2021, 17 (02) : 170 - 182
  • [46] Critical review of the sources of variability in the measurement of the prevalence of Schizophrenia
    Moreno-Kuestner, Berta
    Martin, Carlos
    Almenara, Jose
    SALUD MENTAL, 2014, 37 (02) : 127 - 138
  • [47] Modified Brostro?m repair with suture tape augmentation for lateral ankle instability: A systematic review
    Lewis, T. L.
    Joseph, A.
    Patel, A.
    Ahluwalia, R.
    Ray, R.
    FOOT AND ANKLE SURGERY, 2021, 27 (03) : 278 - 284
  • [48] Effect of Lateral Motion of Ultrasonic Probe on Measurement Accuracy of Internal Tissue Displacement
    Huang, Andy
    Ono, Yuu
    Adler, Andy
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 183 - 186
  • [49] APPLICATION OF TIME RESOLVED SPATIAL PHOTOMETRY (TRSP) TO MEASUREMENT OF LATERAL MOTION IN MEMBRANES
    KAPITZA, HG
    MCGREGOR, G
    JACOBSON, KA
    BIOPHYSICAL JOURNAL, 1984, 45 (02) : A89 - A89
  • [50] SIMULTANEOUS MEASUREMENT OF LONGITUDINAL ROTATION AND LATERAL MOTION OF DIFFUSE SURFACES BY SPECKLE PHOTOGRAPHY
    AGGARWAL, AK
    GUPTA, PC
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1977, 15 (06) : 420 - 423