Numerical evaluation of wind driven ventilator for enhanced indoor air quality

被引:5
|
作者
Lien, Jason [1 ]
Ahmed, Noor [1 ]
机构
[1] Univ New S Wales, Sch Mech & Mfg Engn, Sydney, NSW 2052, Australia
来源
关键词
wind driven ventilator; indoor air quality; energy; COMFORT;
D O I
10.1016/j.proeng.2012.10.120
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present paper presents a numerical analysis of the difference in comfort level inside a room of a residential building when roof top turbine ventilator is installed. This analysis simulates various comfort factors which include the indoor air movement, room temperature, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). Various test cases of ventilator exhaust rate were examined. The results showed that general comfort satisfying international standards in building can be achieved. This study also presents a qualitative and quantitative study of indoor air temperature and overall indoor air flow pattern. A promising conclusion that can be drawn from this study is that wind driven ventilators can play an important role in the design of a cost effective and energy efficient ventilation system inside a building. (C) 2012 The Authors. Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the International Energy Foundation
引用
收藏
页码:124 / 134
页数:11
相关论文
共 50 条
  • [41] Evaluation and comparison of the indoor air quality in different areas of the hospital
    Lee, Hyun-Joo
    Lee, Kang Hyun
    Kim, Dong-Kyu
    MEDICINE, 2020, 99 (52)
  • [42] Evaluation of the Johnson and Ettinger model for prediction of indoor air quality
    Hers, I
    Zapf-Gilje, R
    Johnson, PC
    Li, L
    GROUND WATER MONITORING AND REMEDIATION, 2003, 23 (02): : 119 - 133
  • [43] Evaluation on four sampling schemes for assessing indoor air quality
    Wong, L. T.
    Mui, K. W.
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1119 - 1125
  • [44] Evaluation of health benefits for improving indoor air quality in workplace
    Chau, C. K.
    Hui, W. K.
    Tse, M. S.
    ENVIRONMENT INTERNATIONAL, 2007, 33 (02) : 186 - 198
  • [45] Evaluation of indoor air quality in kindergartens-case study
    Marques, C.
    Ferreira, A.
    Figueiredo, J. P.
    OCCUPATIONAL SAFETY AND HYGIENE IV, 2016, : 375 - 380
  • [46] Evaluation of Indoor Air Quality in Day Care Centres for the Elderly
    Pinto, Mario
    Rebelo, Andreia
    Santos, Joana
    Silva, Manuela Vieira
    SHO 2012: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2012, : 466 - 470
  • [47] Evaluation of the Johnson and Ettinger model for prediction of indoor air quality
    Hers, I
    Zapf-Gilje, R
    Johnson, PC
    Li, L
    GROUND WATER MONITORING AND REMEDIATION, 2003, 23 (01): : 62 - 76
  • [48] Evaluation of Effects of VOCs Released by MDF on Indoor Air Quality
    Jiang L.
    Zhao Z.
    Shen J.
    Meng J.
    Dong H.
    Linye Kexue/Scientia Silvae Sinicae, 2020, 56 (07): : 135 - 141
  • [49] Evaluation of indoor air quality on the basis of measurements of VOC concentrations
    Zabiegala, B
    Przyk, E
    Przyjazny, A
    Namiesnik, J
    CHEMIA ANALITYCZNA, 2000, 45 (01): : 11 - 26
  • [50] Indoor Air Quality Monitoring Systems for Sustainable Medical Rooms and Enhanced Life Quality
    Mohamed, Samah
    Gama, Yomna
    Soltan, Ahmed
    Said, Lobna A.
    2024 IEEE 22ND MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON 2024, 2024, : 1107 - 1110