Enhanced exergy analysis of a bubble-pump-driven LiCl-H2O absorption air-conditioning system

被引:3
|
作者
Aman, Julia [1 ]
Henshaw, Paul [1 ]
Ting, David S-K [1 ]
机构
[1] Univ Windsor, Ctr Engn Innovat, Turbulence & Energy Lab, 401 Sunset Ave, Windsor, ON N9B 3P4, Canada
关键词
bubble pump; LiCl-H2O; vapour absorption refrigeration; exergy analysis; advanced exergy analysis; EXERGOECONOMIC ANALYSES; THERMODYNAMIC ANALYSIS; REFRIGERATION SYSTEM; HEAT; CYCLE; POWER; DESTRUCTIONS; ENERGY;
D O I
10.1504/IJEX.2019.099292
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermally-driven bubble pump can replace the electrical pump in the absorption refrigeration cycle for lifting solution from the absorber to the generator and producing the required refrigerant vapour for the cooling effect. However, the lower efficiency of bubble-pump-driven absorption refrigeration cycle hinders its widespread application. The potential of a bubble-pump-driven LiCl-H2O absorption refrigeration system that can be powered by solar thermal energy or waste heat energy is discussed and analysed in this study. The new concept of enhanced exergy analysis is integrated in the thermodynamic analyses, which quantifies the available exergy destruction of each component for overall system performance improvement. The analyses uncovered that 80% of the total exergy loss is due to each component's own internal irreversibilities, whereas the remaining is through the interaction of the irreversibilities of other components in the system. The analyses revealed that though the highest exergy losses (46%) are in the absorber, priority for improvement should be given to the generator. Furthermore, the exergy losses of the condenser, the evaporator, and the solution heat exchanger are mostly unavoidable and can be reduced by improving the other components of the system.
引用
收藏
页码:333 / 354
页数:22
相关论文
共 50 条
  • [41] Experimental investigation of cooling performance of milk cooling tank with the vapor compressed and solar absorption (LiCl-H2O) cooling system
    Süt soǧutma tankinin buhar sikiştirmali ve güneş enerjili absorpsiyonlu
    [J]. 1600, Gazi Universitesi (31):
  • [42] EXPERIMENTAL INVESTIGATION OF COOLING PERFORMANCE OF MILK COOLING TANK WITH THE VAPOR COMPRESSED AND SOLAR ABSORPTION (LiCl-H2O) COOLING SYSTEM
    Demir, Vedat
    Gunhan, Tuncay
    Sencan Sahin, Arzu
    Ekren, Orhan
    Bilgen, Hamdi
    Erek, Aytunc
    [J]. JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2016, 31 (01): : 29 - 37
  • [43] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    Zhang Kexin
    Li Ming
    Yang Changhai
    Shao Zhiyuan
    Wang Lihong
    [J]. JOURNAL OF THERMAL SCIENCE, 2020, 29 (02) : 408 - 422
  • [44] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    ZHANG Kexin
    LI Ming
    YANG Changhai
    SHAO Zhiyuan
    WANG Lihong
    [J]. Journal of Thermal Science, 2020, 29 (02) : 408 - 422
  • [45] Exergy Analysis of Electric Vehicle Heat Pump Air Conditioning System with Battery Thermal Management System
    Kexin Zhang
    Ming Li
    Changhai Yang
    Zhiyuan Shao
    Lihong Wang
    [J]. Journal of Thermal Science, 2020, 29 : 408 - 422
  • [46] Quantification on the Effects of Liquid-Vapor Separation in Air-Conditioning System by using Advanced Exergy Analysis
    Yunhai Li
    Jianyong Chen
    Xu Lin
    Zhi Yang
    Ying Chen
    Xianglong Luo
    [J]. Journal of Thermal Science, 2020, 29 : 597 - 608
  • [47] Quantification on the Effects of Liquid-Vapor Separation in Air-Conditioning System by using Advanced Exergy Analysis
    LI Yunhai
    CHEN Jianyong
    LIN Xu
    YANG Zhi
    CHEN Ying
    LUO Xianglong
    [J]. Journal of Thermal Science, 2020, 29 (03) : 597 - 608
  • [48] Quantification on the Effects of Liquid-Vapor Separation in Air-Conditioning System by using Advanced Exergy Analysis
    Li, Yunhai
    Chen, Jianyong
    Lin, Xu
    Yang, Zhi
    Chen, Ying
    Luo, Xianglong
    [J]. JOURNAL OF THERMAL SCIENCE, 2020, 29 (03) : 597 - 608
  • [49] Energy and exergy performance analysis of a marine rotary desiccant air-conditioning system based on orthogonal experiment
    Zhu, Jun
    Chen, Wu
    [J]. ENERGY, 2014, 77 : 953 - 962
  • [50] Hybrid heat-pump-driven liquid-desiccant system: Experimental performance analysis for residential air-conditioning applications
    Lee, Jae-Hee
    Jeong, Jae-Weon
    [J]. APPLIED THERMAL ENGINEERING, 2021, 195