Enhanced exergy analysis of a bubble-pump-driven LiCl-H2O absorption air-conditioning system

被引:3
|
作者
Aman, Julia [1 ]
Henshaw, Paul [1 ]
Ting, David S-K [1 ]
机构
[1] Univ Windsor, Ctr Engn Innovat, Turbulence & Energy Lab, 401 Sunset Ave, Windsor, ON N9B 3P4, Canada
关键词
bubble pump; LiCl-H2O; vapour absorption refrigeration; exergy analysis; advanced exergy analysis; EXERGOECONOMIC ANALYSES; THERMODYNAMIC ANALYSIS; REFRIGERATION SYSTEM; HEAT; CYCLE; POWER; DESTRUCTIONS; ENERGY;
D O I
10.1504/IJEX.2019.099292
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermally-driven bubble pump can replace the electrical pump in the absorption refrigeration cycle for lifting solution from the absorber to the generator and producing the required refrigerant vapour for the cooling effect. However, the lower efficiency of bubble-pump-driven absorption refrigeration cycle hinders its widespread application. The potential of a bubble-pump-driven LiCl-H2O absorption refrigeration system that can be powered by solar thermal energy or waste heat energy is discussed and analysed in this study. The new concept of enhanced exergy analysis is integrated in the thermodynamic analyses, which quantifies the available exergy destruction of each component for overall system performance improvement. The analyses uncovered that 80% of the total exergy loss is due to each component's own internal irreversibilities, whereas the remaining is through the interaction of the irreversibilities of other components in the system. The analyses revealed that though the highest exergy losses (46%) are in the absorber, priority for improvement should be given to the generator. Furthermore, the exergy losses of the condenser, the evaporator, and the solution heat exchanger are mostly unavoidable and can be reduced by improving the other components of the system.
引用
收藏
页码:333 / 354
页数:22
相关论文
共 50 条
  • [1] Bubble-pump-driven LiBr-H2O and LiCl-H2O absorption air-conditioning systems
    Aman, Julia
    Henshaw, Paul
    Ting, David S-K
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 6 : 316 - 322
  • [2] Exergy Based Analysis of LiCl-H2O Absorption Cooling System
    Patel, Jatin
    Pandya, Bhargav
    Mudgal, Anurag
    [J]. INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 261 - 269
  • [3] A GEP model for energy and exergy analysis of LiCl-H2O absorption cooling systems
    Sahin, Arzu Sencan
    Kovaci, Tugba
    Dikmen, Erkan
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 43 (17) : 2099 - 2108
  • [4] Performance Enhancement in LiCl-H2O and LiBr-H2O Absorption Cooling Systems Through an Advanced Exergy Analysis
    Mody, Parth
    Patel, Jatin
    Modi, Nishant
    Pandya, Bhargav
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (01)
  • [5] Energy and exergy analysis of a double effect LiBr-H2O and LiCl-H2O chillers
    Kilic, M.
    Ravul, H. B.
    [J]. BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 : 312 - 317
  • [6] Energy and exergy analysis of absorption-compression hybrid air-conditioning system
    Mohammadi, S. M. Hojjat
    Ameri, Mehran
    [J]. HVAC&R RESEARCH, 2013, 19 (06): : 744 - 753
  • [7] Glass formation in the LiCl-H2O system
    Kirilenko, I. A.
    [J]. RUSSIAN JOURNAL OF INORGANIC CHEMISTRY, 2011, 56 (05) : 776 - 778
  • [8] Glass formation in the LiCl-H2O system
    I. A. Kirilenko
    [J]. Russian Journal of Inorganic Chemistry, 2011, 56 : 776 - 778
  • [9] Monitoring and analysis of an absorption air-conditioning system
    de Viñaspre, MP
    Bourouis, M
    Coronas, A
    García, A
    Soto, V
    Pinazo, JM
    [J]. ENERGY AND BUILDINGS, 2004, 36 (09) : 933 - 943
  • [10] Dynamic analysis of an air-conditioning system with a heat pump
    Balen, I
    Donjerkovic, P
    Galaso, I
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2000, 46 (07): : 413 - 421