Simultaneous PET-MRI Confirms That Cerebral Blood Flow Does Not Confound PET Neuroreceptor Activation Studies

被引:1
|
作者
Nummenmaa, Lauri [1 ,2 ]
Tuominen, Lauri [3 ,4 ]
Hirvonen, Jussi [1 ,5 ]
机构
[1] Univ Turku, Turku PET Ctr, SF-20500 Turku, Finland
[2] Univ Turku, Dept Psychol, SF-20500 Turku, Finland
[3] Massachusetts Gen Hosp, Dept Psychiat, Boston, MA 02114 USA
[4] Harvard Med Sch, Boston, MA 02114 USA
[5] Univ Turku, Dept Radiol, SF-20500 Turku, Finland
来源
ACS CHEMICAL NEUROSCIENCE | 2018年 / 9卷 / 02期
基金
芬兰科学院;
关键词
Neuroreceptor; dopamine; positron emission tomography; blood flow; arterial spin labeling;
D O I
10.1021/acschemneuro.7b00489
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Positron emission tomography (PET) and endogenous competition paradigms are widely used for studying neuroreceptor activation in humans in Vivo. Changes in cerebral blood triggered by the experimentation, such as amphetamine administration, could influence both tracer delivery and washout, thus biasing the results. A recent study tested this assumption in baboons by measuring radiotracer binding with PET while measuring simultaneously cerebral blood flow with arterial spin labeled functional magnetic resonance imaging. Cerebral blood flow was modulated by CO2 inhalation. Hypercapnia led to substantial alterations in blood flow with no detectable alteration in binding of the reversibly binding radiotracers [C-11]raclopride and [F-18] fallypride. These results rule out a serious confound for the endogenous competition paradigm, and demonstrate the importance of simultaneous PET and MRI measurements when studying brain function.
引用
收藏
页码:159 / 161
页数:5
相关论文
共 50 条
  • [31] Simultaneous emission and transmission imaging for PET-MRI using time-of-flight information
    Mollet, Pieter
    Keereman, Vincent
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [32] Results from Prototype II of the BNL Simultaneous PET-MRI Dedicated Breast Scanner
    Ravindranath, B.
    Junnarkar, S. S.
    Purschke, M. L.
    Maramraju, S. H.
    Hong, X.
    Tomasi, D.
    Bennett, D.
    Cheng, K.
    Southekal, S. S.
    Stoll, S. P.
    Pratte, J. -F.
    Vaska, P.
    Woody, C. L.
    Schlyer, D. J.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3315 - +
  • [33] Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer
    Cavaliere, Carlo
    Romeo, Valeria
    Aiello, Marco
    Mesolella, Massimo
    Iorio, Brigida
    Barbuto, Luigi
    Cantone, Elena
    Nicolai, Emanuele
    Covello, Mario
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 47 - 55
  • [34] Interindividual and regional variations in coupling of cerebral blood flow and metabolism measured by PET and MRI
    Henriksen, O.
    Vestergaard, M.
    Lindberg, U.
    Aachmann-Andersen, N. J.
    Lisbjerg, K.
    Christensen, S.
    Olsen, N.
    Rasmussen, P.
    Larsson, H.
    Law, I.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 153 - 153
  • [35] Comparison of quantitative cerebral blood flow measured by simultaneous arterial spin labeling MRI and oxygen-15 labeled gases PET scans using integrated PET/MRI scanner.
    Kubo, Hitoshi
    Ito, Hiroshi
    Takahashi, Kazuhiro
    Ishii, Shiro
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [36] Initial results from the BNL dedicated simultaneous PET-MRI breast imaging system prototype
    Ravindranath, Bosky
    Junnarkar, Sachin
    Maramraju, Sri Harsha
    Southekal, Sudeepti
    Purschke, Martin
    Stoll, Sean
    Tomasi, Dardo
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [37] Neurochemical characterization of 5-HT2AR partial agonists with simultaneous PET-MRI
    Bagdasarian, Frederick A.
    Larsen, Kristian
    Deng, Hong Ping
    Fisher, Patrick M.
    Mandeville, Joseph B.
    Sander, Christin Y.
    Wey, Hsiao-Ying
    Hansen, Hanne D.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2024,
  • [38] Simultaneous PET-MRI in oncology: A solution looking for a problem (vol 30, pg 1342, 2012)
    Yankeelov, Thomas E.
    Peterson, Todd E.
    Abramson, Richard G.
    Izquierdo-Garcia, David
    Arlinghaus, Lori R.
    Li, Xia
    Atuegwu, Nkiruka C.
    Catana, Ciprian
    Manning, H. Charles
    Fayad, Zahi A.
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (05) : 796 - 796
  • [39] Noise contamination from PET blood sampling pump: Effects on structural MRI image quality in simultaneous PET/MR studies
    Bartlett, Elizabeth
    DeLorenzo, Christine
    Parsey, Ramin
    Huang, Chuan
    MEDICAL PHYSICS, 2018, 45 (02) : 678 - 686
  • [40] Cerebral activation studies with PET and fMRT: Clinical relevance?
    Brandt, T
    NERVENARZT, 1995, 66 (12): : 942 - 945