Hyperpolarized 3He Magnetic Resonance Imaging: Comparison with Four-dimensional X-ray Computed Tomography Imaging in Lung Cancer

被引:72
|
作者
Mathew, Lindsay [1 ]
Wheatley, Andrew [1 ]
Castillo, Richard [2 ,4 ]
Castillo, Edward [3 ,5 ]
Rodrigues, George [6 ,7 ]
Guerrero, Thomas [3 ,4 ,5 ]
Parraga, Grace [1 ,7 ,8 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Texas MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
[4] Univ Texas Houston, Grad Sch Biomed Sci Houston, Houston, TX USA
[5] Rice Univ, Dept Computat & Appl Math, Houston, TX USA
[6] London Reg Canc Program, Radiat Oncol Program, London, ON, Canada
[7] Univ Western Ontario, Dept Oncol, London, ON, Canada
[8] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
基金
美国国家卫生研究院; 加拿大健康研究院;
关键词
Hyperpolarized He-3 magnetic resonance imaging; four-dimensional computed tomography; functional lung imaging; ventilated volume; ventilation defect; OBSTRUCTIVE PULMONARY-DISEASE; APPARENT DIFFUSION-COEFFICIENTS; VENTILATION; REGISTRATION; XE-129; CT; REPRODUCIBILITY; SPECTROSCOPY; DIAGNOSIS; DEFECTS;
D O I
10.1016/j.acra.2012.08.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Pulmonary functional imaging using four-dimensional x-ray computed tomographic (4DCT) imaging and hyperpolarized He-3 magnetic resonance imaging (MRI) provides regional lung function estimates in patients with lung cancer in whom pulmonary function measurements are typically dominated by tumor burden. The aim of this study was to evaluate the quantitative spatial relationship between 4DCT and hyperpolarized 3He MRI ventilation maps. Materials and Methods: Eleven patients with lung cancer provided written informed consent to 4DCT imaging and MRI performed within 11 +/- 14 days. Hyperpolarized He-3 MRI was acquired in breath-hold after inhalation from functional residual capacity of 1 L hyperpolarized He-3, whereas 4DCT imaging was acquired over a single tidal breath of room air. For hyperpolarized 3He MRI, the percentage ventilated volume was generated using semiautomated segmentation; for 4DCT imaging, pulmonary function maps were generated using the correspondence between identical tissue elements at inspiratory and expiratory phases to generate percentage ventilated volume. Results: After accounting for differences in image acquisition lung volumes (He-3 MRI: 1.9 +/- 0.5 L ipsilateral, 2.3 +/- 0.7 L contralateral; 4DCT imaging: 1.2 +/- 0.3 L ipsilateral, 1.3 +/- 0.4 L contralateral), there was no significant difference in percentage ventilated volume between hyperpolarized He-3 MRI (72 +/- 11% ipsilateral, 79 +/- 12% contralateral) and 4DCT imaging (74 +/- 3% ipsilateral, 75 +/- 4% contralateral). Spatial correspondence between 4DCT and He-3 MRI ventilation was evaluated using the Dice similarity coefficient index (ipsilateral, 86 +/- 12%; contralateral, 88 +/- 12%). Conclusions: Despite rather large differences in image acquisition breathing maneuvers, good spatial and significant quantitative agreement was observed for ventilation maps on hyperpolarized He-3 MRI and 4DCT imaging, suggesting that pulmonary regions with good lung function are similar between modalities in this small group of patients with lung cancer.
引用
收藏
页码:1546 / 1553
页数:8
相关论文
共 50 条
  • [31] Pulmonary Computed Tomography And 3he Magnetic Resonance Imaging Of Gold Unclassified Ex-Smokers: Does Imaging Matter?
    Pike, D.
    Kirby, M.
    Svenningsen, S.
    Sin, D. D.
    McCormack, D. G.
    Coxson, H. O.
    Parraga, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [32] Parathyroid Imaging Four-dimensional Computed Tomography, Sestamibi, and Ultrasonography
    Strauss, Sara B.
    Roytman, Michelle
    Phillips, C. Douglas
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2021, 31 (03) : 379 - 395
  • [33] Dynamic ventilation imaging from four-dimensional computed tomography
    Guerrero, T
    Sanders, K
    Castillo, E
    Zhang, Y
    Bidaut, L
    Pan, TS
    Komaki, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 777 - 791
  • [34] Availability of a simplified lung ventilation imaging algorithm based on four-dimensional computed tomography
    Tian, Yuan
    Miao, Junjie
    Liu, Zhiqiang
    Huang, Peng
    Wang, Wenqin
    Wang, Xin
    Zhai, Yirui
    Wang, Jingbo
    Li, Minghui
    Ma, Pan
    Zhang, Ke
    Yan, Hui
    Dai, Jianrong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 53 - 58
  • [35] Comparison of hyperpolarized 3He MRI rat lung volume measurement with micro-computed tomography
    Sharif, M. Reza Akhavan
    Lam, Wilfred W.
    Ouriadov, Alexei V.
    Holdsworth, David W.
    Santyr, Giles E.
    NMR IN BIOMEDICINE, 2010, 23 (04) : 359 - 367
  • [36] Regional pulmonary response to a methacholine challenge using hyperpolarized 3He magnetic resonance imaging
    Costella, Stephen
    Kirby, Miranda
    Maksym, Geoffrey N.
    Mccormack, David G.
    Paterson, Nigel A. M.
    Parraga, Grace
    RESPIROLOGY, 2012, 17 (08) : 1237 - 1246
  • [37] Hyperpolarized 3He gas production by metastability exchange optical pumping for magnetic resonance imaging
    Suchanek, K
    Cieslar, K
    Olejniczak, Z
    Palasz, T
    Suchanek, M
    Dohnalik, T
    OPTICA APPLICATA, 2005, 35 (02) : 263 - 276
  • [38] Mapping and quantifying hyperpolarized 3He magnetic resonance imaging apparent diffusion coefficient gradients
    Evans, Andrea
    McCormack, David G.
    Santyr, Giles
    Parraga, Grace
    JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (02) : 693 - 699
  • [39] Asthma:: Findings with hyperpolarized 3He MR lung ventilation imaging
    Altes, TA
    Powers, PL
    Knight-Scott, J
    De Lange, EE
    Alford, BA
    Brookeman, JR
    RADIOLOGY, 2000, 214 (02) : 609 - 610
  • [40] Hyperpolarized 3He magnetic resonance imaging of ventilation after bacterial lipopolysaccharide exposure in mice
    Thomas, Abraham
    Voltz, James
    Fubara, Boma
    Driehuys, Bastiaan
    Zeldin, Darryl
    FASEB JOURNAL, 2008, 22