The influence of chain length and base sequence on the pharmacokinetic behavior of 99mTc-morpholinos in mice

被引:0
|
作者
Liu, G [1 ]
Zhang, S [1 ]
He, J [1 ]
Liu, N [1 ]
Gupta, S [1 ]
Rusckowski, M [1 ]
Hnatowich, DJ [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Div Nucl Med, Worcester, MA 01655 USA
来源
QUARTERLY JOURNAL OF NUCLEAR MEDICINE | 2002年 / 46卷 / 03期
关键词
pharmacokinetics; oligonucleotides; base sequence; technetium; neoplasms; radionuclide imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Despite in vivo use now over several years, in particular for nuclear medicine imaging, the influences on pharmacokinetics of chain length and base sequence of radiolabeled oligomers; has not been investigated. Methods. As test oligomer, morpholinos (MORFs), a DNA analogue, were radiolabeled with Tc-99m via MAG(3) and the pharmacokinctics in normal mice determined for 3 chain lengths (15,18 and 25 mer) and 2 base sequences (MORF and its complement cMORF). In addition, LS174T-tumor bearing nude mice received the anti-CEA antibody MN14 (Immunomedics) conjugated either with MORF15 or MORF18 and subsequently received Tc-99m-labeled cMORF15 or cMORF18 respectively in a pretargeting strategy. Results. In normal mice, after 1 hr, regardless of chain length or sequence, all labeled MORFs and cMORFs accumulated only slightly in all tissues (e.g. at 3 hr <0.15 ID%/g) except in kidneys. Besides being excessive, the kidneys were the only tissue with levels dependent upon chain length (e.g. at 1 hr, 5, 7 and 22 IDO/o/g for MORF15, 18 and 25, respectively) and sequence (e.g. at 3 hrs 9 ID%/g for MORF25 and 21 IDO/o/g for cMORF25). Identical biodistribution trends were observed in tumored mice with all tissues including tumor Showing levels independent of chain length or base sequence except for kidneys. Furthermore, while all other tissues cleared in the interval from 1-3 hrs, kidney levels remained constant in both normal and tumored animals. Largely because of these differences in kidneys, images obtained by pretargeting with Tc-99m-cMORF15 were superior compared to Tc-99m-cMORF18 (images of control animals not receiving the antibody showed no tumor at all). Conclusions. judged by radiolabel accumulations in tissue, the pharmacokinetics of Tc-99m labeled morpholinos were independent of chain length and base sequence. The only obvious exception was kidneys in which accumulations were significantly higher for the longer chain lengths and significantly different for cMORF vs MORF. These results show that chain length and base sequences may be varied to alter the pharmacokinetics of radiolabeled oligomers in nuclear medicine imaging studies.
引用
收藏
页码:233 / 243
页数:11
相关论文
共 50 条
  • [21] Influence of the Bifunctional Chelator on the Pharmacokinetic Properties of 99mTc(CO)3-Labeled Cyclic α-Melanocyte Stimulating Hormone Analog
    Morais, Mauricio
    Oliveira, Bruno L.
    Correia, Joao D. G.
    Oliveira, Maria Cristina
    Angeles Jimenez, Maria
    Santos, Isabel
    Raposinho, Paula D.
    JOURNAL OF MEDICINAL CHEMISTRY, 2013, 56 (05) : 1961 - 1973
  • [22] THEORETICAL-STUDIES ON B-DNA DIMENSIONS AND FLEXIBILITY - THEIR BASE SEQUENCE AND CHAIN-LENGTH DEPENDENCE
    MAROUN, RC
    OLSON, WK
    BIOPHYSICAL JOURNAL, 1986, 49 (02) : A124 - A124
  • [23] Thermotropic behavior of asymmetric chain length catanionic surfactants: The influence of the polar head group
    Silva, BFB
    Marques, EF
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 290 (01) : 267 - 274
  • [24] Influence of Sodium Phosphate Salts with Different Chain Length on the Flotation Behavior of Magnesite and Dolomite
    Bai, Junzhi
    Wang, Jizhen
    Yin, Wanzhong
    Chen, Xiangxiang
    MINERALS, 2020, 10 (11) : 1 - 11
  • [25] Oligonucleotides covalently linked to an acridine at artificial abasic site: Influence of linker length and the base-sequence
    Fukui, K
    Iwane, K
    Shimidzu, T
    Tanaka, K
    TETRAHEDRON LETTERS, 1996, 37 (28) : 4983 - 4986
  • [26] CRYSTALLIZATION AND STEREO ASSOCIATION OF STEREOREGULAR PMMA .1. INFLUENCE OF SEQUENCE LENGTH ON CRYSTALLIZATION BEHAVIOR
    KONNECKE, K
    REHAGE, G
    COLLOID AND POLYMER SCIENCE, 1981, 259 (11) : 1062 - 1069
  • [27] Water-AOT-alkylbenzene microemulsions: Influence of alkyl chain length on structure and percolation behavior
    Appel, Markus
    Spehr, Tinka Luise
    Wipf, Robert
    Stuehn, Bernd
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 376 : 140 - 145
  • [28] INFLUENCE OF THE CHAIN-LENGTH ON THE BIOLOGICAL BEHAVIOR OF I-131 FATTY-ACIDS
    RICHE, F
    MATHIEU, JP
    COMET, M
    VIDAL, M
    PERNIN, C
    MARTIBATLLE, D
    BUSQUET, G
    BARDY, A
    JOURNAL DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1983, 7 (02): : 97 - 106
  • [29] DNA CHAIN-LENGTH MARKERS AND THE INFLUENCE OF BASE COMPOSITION ON ELECTROPHORETIC MOBILITY OF OLIGODEOXYRIBONUCLEOTIDES IN POLYACRYLAMIDE-GELS
    FRANK, R
    KOSTER, H
    NUCLEIC ACIDS RESEARCH, 1979, 6 (06) : 2069 - 2087
  • [30] Influence of the denticity of ligand systems on the in vitro and in vivo behavior of 99mTc(I)-tricarbonyl complexes:: A hint for the future functionalization of biomolecules
    Schibli, R
    La Bella, R
    Alberto, R
    Garcia-Garayoa, E
    Ortner, K
    Abram, U
    Schubiger, PA
    BIOCONJUGATE CHEMISTRY, 2000, 11 (03) : 345 - 351