Generation of low-contrast sinusoidal test patterns on a high-brightness display

被引:7
|
作者
Sund, Patrik [1 ]
Bath, Magnus
Ungsten, Linda
Mansson, Lars Gunnar
机构
[1] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Dept Radiat Phys, SE-41345 Gothenburg, Sweden
关键词
vision research; Barten model; monitor calibration; contrast threshold; eye adaptation; sinusoidal test patterns;
D O I
10.1889/1.2372425
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
By using a technique of addressing individual subpixels, low-contrast sinusoidal test patterns were generated on a high-brightness color LCD. Detection tasks were performed using 2AFC experiments, and the value obtained for the contrast threshold was found to agree well with previously published data. As long as the shape of the pattern was close to sinusoidal, a good correlation was found between pattern contrast and detection rate. The influence of the eye-adaptation luminance level was studied and compared to the f-factor published by Barten. Luminance non-uniformities in the background did not cause any significant change in the detection threshold.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [21] High-brightness hybrid compressive light field display with improved image quality
    Zhu, Liming
    Chen, Qiyang
    Chen, Tao
    Lv, Guoqiang
    Feng, Qibin
    Wang, Zi
    [J]. OPTICS LETTERS, 2023, 48 (23) : 6172 - 6175
  • [22] 3D High-Brightness Autostereoscopic Display Systems with LED Backlight
    Lai, Yeong-Lin
    Lin, Wei-Kai
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2012, : 614 - 615
  • [23] Positive Correlation of High- and Low-Contrast ERG in Glaucoma Patients with Negative Correlation of High- and Low-Contrast VEP Latency
    Trevino, Rick
    Sponsel, William Eric
    Johnson, Susan Ly
    Reilly, Matthew Aaron
    Majcher, Carolyn
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] LOW-CONTRAST VISUAL-ACUITY TEST FOR PEDIATRIC USE
    REGAN, D
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1988, 23 (05): : 224 - 227
  • [25] LOW-CONTRAST THERMAL RESOLUTION TEST TARGETS - A NEW APPROACH
    GEIST, J
    NOVOTNY, DB
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (06) : 631 - 646
  • [26] GLARE DISABILITY TEST BASED ON A LOW-CONTRAST LETTER TECHNIQUE
    ABRAHAMSSON, M
    SJOSTRAND, J
    HARD, AL
    [J]. OPHTHALMIC RESEARCH, 1988, 20 (02) : 94 - 94
  • [27] Development of a Low-Energy, High-Brightness μ+ Beam Line
    Eggenberger, A.
    Belosevic, I.
    Wichmann, G.
    [J]. PROCEEDINGS OF THE SEVENTH MEETING ON CPT AND LORENTZ SYMMETRY, 2017, : 235 - 237
  • [28] High-brightness low-power consumption microLED arrays
    Bonar, James R.
    Valentine, Gareth J.
    Gong, Zheng
    Small, James
    Gorton, Steve
    [J]. LIGHT-EMITTING DIODES: MATERIALS, DEVICES, AND APPLICATIONS FOR SOLID STATE LIGHTING XX, 2016, 9768
  • [29] Defect detection of uneven brightness in low-contrast images using basis image representation
    Tsneg, Yan-Hsin
    Tsai, Du-Ming
    [J]. PATTERN RECOGNITION, 2010, 43 (03) : 1129 - 1141
  • [30] Determining contrast sensitivity functions for monochromatic light emitted by high-brightness LEDs
    Ramamurthy, V
    Narendran, N
    Freyssinier, JP
    Raghavan, R
    Boyce, P
    [J]. THIRD INTERNATIONAL CONFERENCE ON SOLID STATE LIGHTING, 2004, 5187 : 294 - 300