Rapid detection of Bombyx mori bidensovirus by loop-mediated isothermal amplification based lateral flow dipstick assay for field applications

被引:5
|
作者
Lu, Peng [1 ,8 ]
He, Yaling [2 ,4 ]
Lin, Feng [3 ]
Pan, Ye [7 ]
Yu, Qian [1 ]
Guo, Zhongjian [1 ]
Li, Chengjun [1 ]
Wang, Huiying [5 ]
Yao, Qin [1 ]
Fu, Yan [6 ]
Chen, Keping [1 ]
机构
[1] Jiangsu Univ, Inst Life Sci, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Fudan Univ, Collage Life Sci, Shanghai 200032, Peoples R China
[3] Zhejiang Inst Freshwater Fisheries, Huzhou 313001, Peoples R China
[4] Chinese Acad Sci, Inst Pasteur Shanghai, Key Lab Mol Virol & Immunol, Shanghai 200031, Peoples R China
[5] Jiangsu Well Biotechnol Co Ltd, Changzhou 213149, Peoples R China
[6] Anhui Microanaly Gene Co Ltd, Hefei 230601, Anhui, Peoples R China
[7] Jiangsu Univ, Lab Anim Res Ctr, Zhenjiang 212013, Jiangsu, Peoples R China
[8] Guangdong Silda Pupa & Silk Inc, Shaoguan, Peoples R China
基金
中国博士后科学基金; 美国国家科学基金会; 中国国家自然科学基金;
关键词
BmBDV; Bombyx mori; Sericulture; LAMP-LFD; Rapid detection; Field applications; SPOT SYNDROME VIRUS; SENSITIVE DETECTION; LAMP;
D O I
10.1016/j.jip.2019.03.003
中图分类号
Q95 [动物学];
学科分类号
071002 ;
摘要
Bombyx mori bidensovirus (BmBDV), is the only bipartite single-stranded DNA (ssDNA) insect virus reported to date. BmBDV causes fatal flacherie disease in silkworm, resulting in large economic losses to sericulture. We developed a loop-mediated isothermal amplification with lateral flow dipstick (LAMP-LFD) method that can successfully and rapidly detect BmBDV DNA with a low limit of detection (5 fg, 400 copies of the BmBDV genome). The method was evaluated and improved for direct field diagnosis using silkworm faeces. In the field, the actual limit of detection was similar to 50 fg (4000 copies of the BmBDV genome). The results demonstrated that, compared with traditional methods for BmBDV detection, our new LAMP-LFD method was much more rapid, sensitive and cost-effective, with less dependence on equipment, making it easier to use. The method has potential to be translated into a new diagnostic product for field applications in the sericulture industry.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [11] Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella
    Liang Wang
    Guofu Chen
    Chunyun Zhang
    Yuanyuan Wang
    Rui Sun
    Environmental Science and Pollution Research, 2020, 27 : 4246 - 4257
  • [12] Sensitive and rapid detection of Prymnesium parvum (Haptophyceae) by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Zhu, Peng
    Huang, Hai-Long
    Zhou, Cheng-Xu
    Xu, Jilin
    Qiao, Long-Liang
    Dang, Chen-Yang
    Pang, Jian-Hu
    Gao, Wei-Fang
    Yan, Xiao-Jun
    AQUACULTURE, 2019, 505 : 199 - 205
  • [13] Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick
    Liu, Zhi-Ke
    Zhang, Qiu-Yu
    Yang, Ning-Ning
    Xu, Ming-Guo
    Xu, Jin-Feng
    Jing, Ming-Long
    Wu, Wen-Xing
    Lu, Ya-Dong
    Shi, Feng
    Chen, Chuang-Fu
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2019, 29 (03) : 454 - 464
  • [14] Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella
    Wang, Liang
    Chen, Guofu
    Zhang, Chunyun
    Wang, Yuanyuan
    Sun, Rui
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (04) : 4246 - 4257
  • [15] Development of Loop-Mediated Isothermal Amplification Combined with Lateral Flow Dipstick Assay for a Rapid and Sensitive Detection of Cystic Echinococcosis in Livestock in Kenya
    Badoul, Nasser Arreh
    Kagira, John
    Ng'ong'a, Florence
    Dinka, Hunduma
    JOURNAL OF TROPICAL MEDICINE, 2022, 2022
  • [16] The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum
    Huang, Hai-Long
    Zhu, Peng
    Zhou, Cheng-Xu
    He, Shan
    Yan, Xiao-Jun
    HARMFUL ALGAE, 2017, 62 : 20 - 29
  • [17] Detection of cyprinid herpesvirus 2 by loop-mediated isothermal amplification in combination with a lateral flow dipstick
    Li, Yanli
    Lin, Feng
    Sun, Lihui
    Huang, Aixia
    Chen, Jianming
    Hao, Guijie
    Yuan, Xuemei
    Zhang, Haiqi
    Su, Shengqi
    MOLECULAR AND CELLULAR PROBES, 2020, 50
  • [18] The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus
    Prompamorn, P.
    Sithigorngul, P.
    Rukpratanporn, S.
    Longyant, S.
    Sridulyakul, P.
    Chaivisuthangkura, P.
    LETTERS IN APPLIED MICROBIOLOGY, 2011, 52 (04) : 344 - 351
  • [19] Shrimp hepatopancreatic parvovirus detection by combining loop-mediated isothermal amplification with a lateral flow dipstick
    Nimitphak, Tongchai
    Kiatpathomchai, Wansika
    Flegel, T. W.
    JOURNAL OF VIROLOGICAL METHODS, 2008, 154 (1-2) : 56 - 60
  • [20] Application of loop-mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax
    Yongkiettrakul, Suganya
    Jaroenram, Wansadaj
    Arunrut, Narong
    Chareanchim, Wanwisa
    Pannengpetch, Supicha
    Suebsing, Rungkarn
    Kiatpathomchai, Wansika
    Pornthanakasem, Wichai
    Yuthavong, Yongyuth
    Kongkasuriyachai, Darin
    PARASITOLOGY INTERNATIONAL, 2014, 63 (06) : 777 - 784