Experimental Study of Humidity Effect On Charge Measurement of An Ionization Chamber in Clinical High-Energy Photon Beams

被引:0
|
作者
Sato, Y. [1 ]
Shimizu, M. [1 ]
Morishita, Y. [1 ]
Sato, M. [2 ]
Hoshina, M. [2 ]
机构
[1] Natl Metrol Insiture Japan, Tsukuba, Ibaraki, Japan
[2] Komazawa Univ, Grad Sch Hlth Sci, Setagaya Ku, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:2955 / 2956
页数:2
相关论文
共 50 条
  • [41] DETERMINATION OF ABSORBED DOSE IN HIGH-ENERGY ELECTRON AND PHOTON RADIATION BY MEANS OF AN UNCALIBRATED IONIZATION-CHAMBER
    KLEVENHAGEN, SC
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (02): : 239 - 253
  • [42] Energy resolution of gas ionization chamber for high-energy heavy ions
    Sato, Yuki
    Taketani, Atsushi
    Fukuda, Naoki
    Takeda, Hiroyuki
    Kameda, Daisuke
    Suzuki, Hiroshi
    Shimizu, Yohei
    Nishimura, Daiki
    Fukuda, Mitsunori
    Inabe, Naohito
    Murakami, Hiroyuki
    Yoshida, Koichi
    Kubo, Toshiyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (01)
  • [43] LOSS OF ELECTRONS FROM COLLECTING ELECTRODE IN HIGH-ENERGY PHOTON BEAMS INVESTIGATED WITH A DOUBLE EXTRAPOLATION CHAMBER
    FOCHT, EF
    MEURK, ML
    RADIOLOGY, 1956, 66 (01) : 101 - 102
  • [44] Calculation of the characteristics of clinical high-energy photon beams with EGS5-MPI
    Shimizu, M.
    Morishita, Y.
    Kato, M.
    Kurosawa, T.
    Tanaka, T.
    Takata, N.
    Saito, N.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [45] Wall correction factors for calibration of plane-parallel ionization chambers with high-energy photon beams
    Araki, F
    Ikeda, R
    Shirakawa, Y
    Shimonobou, T
    Moribe, N
    Takada, T
    Takahashi, M
    Oura, H
    Matoba, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2509 - 2517
  • [46] Making Plane-Parallel Ionization Chambers Available for Reference Dosimetry of High-Energy Photon Beams
    Muir, B. R.
    McEwen, M. R.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [47] THE INFLUENCE OF IONIZATION-CHAMBER AND PHANTOM DESIGN ON THE MEASUREMENT OF LUNG DOSE IN PHOTON BEAMS
    RICE, RK
    HANSEN, JL
    CHIN, LM
    MIJNHEER, BJ
    BJARNGARD, BE
    MEDICAL PHYSICS, 1988, 15 (06) : 884 - 890
  • [48] MEASUREMENTS WITH AN IONIZATION-CHAMBER FREE OF POLARITY EFFECT IN HIGH-ENERGY ELECTRON DOSIMETRY
    MARKUS, B
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 669 - &
  • [49] Experimental and Monte-Carlo characterization of the novel compact ionization chamber PTW 31023 for reference and relative dosimetry in high energy photon beams
    Buesing, Isabel
    Brant, Andre
    Lange, Tobias
    Delfs, Bjoern
    Poppinga, Daniela
    Kranzer, Rafael
    Looe, Hui Khee
    Poppe, Bjoern
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 303 - 313
  • [50] Investigation of the Energy Dependence of Various 2D Arrays in High-Energy Clinical Photon Beams
    Voges, S.
    Stelljes, T.
    Kretschmer, J.
    Brodbek, L.
    Looe, H.
    Poppe, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E608 - E608