Optimal Transmission Line Switching Under Geomagnetic Disturbances

被引:26
|
作者
Lu, Mowen [1 ]
Nagarajan, Harsha [2 ]
Yamangil, Emre [2 ]
Bent, Russell [3 ]
Backhaus, Scott [3 ]
Barnes, Arthur [3 ]
机构
[1] Clemson Univ, Dept Ind Engn, Clemson, SC 29634 USA
[2] Los Alamos Natl Lab, Ctr Nonlinear Studies, Los Alamos, NM 87545 USA
[3] Los Alamos Natl Lab, Informat Syst & Modeling Div A 1, Los Alamos, NM 87545 USA
关键词
ACOPF; convex relaxations; GIC; GMD; transmission line switching; INDUCED CURRENTS; SYSTEM;
D O I
10.1109/TPWRS.2017.2761178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically induced currents (GICs) can saturate transformers, induce hot spot heating, and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal alternating current (AC), and 2) reactive power losses as a function of GIC. We use this model to derive an optimization problem that protects power systems from GIC impacts through line switching, generator redispatch, and load shedding. We employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and the UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of optimal switching decisions with respect to GMD direction.
引用
收藏
页码:2539 / 2550
页数:12
相关论文
共 50 条
  • [41] Probabilistic Security Analysis of Optimal Transmission Switching
    Henneaux, Pierre
    Kirschen, Daniel S.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (01) : 508 - 517
  • [42] The Influence of Weak Geomagnetic Disturbances on the Rat Cardiovascular System under Natural and Shielded Geomagnetic Field Conditions
    Kuzmenko N.V.
    Shchegolev B.F.
    Pliss M.G.
    Tsyrlin V.A.
    [J]. Biophysics, 2019, 64 (1) : 109 - 116
  • [43] Formation of proton fluxes under the radiation belts during geomagnetic disturbances
    Yu. V. Gotselyuk
    S. N. Kuznetsov
    B. Yu. Yushkov
    [J]. Solar System Research, 2007, 41 : 439 - 446
  • [44] TRANSMISSION-LINE SWITCHING-SYSTEM
    SUZUKI, M
    MIYASAKI, M
    TSUKUI, A
    SAGARA, Y
    [J]. NEC RESEARCH & DEVELOPMENT, 1980, (57): : 46 - 52
  • [45] OPTOELECTRONIC SWITCHING IN A STUB TRANSMISSION-LINE
    BUCK, JA
    LI, KK
    WHINNERY, JR
    [J]. JOURNAL OF APPLIED PHYSICS, 1980, 51 (01) : 769 - 771
  • [46] A Framework to Avoid Maloperation of Transformer Differential Protection Under Geomagnetic Disturbances
    Zandian, Mehdi
    Ameli, Amir
    Ghafouri, Mohsen
    Hassani, Reza
    Rezaei-Zare, Afshin
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 763 - 777
  • [47] Peculiarities of Power Transit by Overhead Lines Under Conditions of Geomagnetic Disturbances
    Kuvshinov, Aleksey A.
    Chernenko, Aleksey N.
    Vakhnina, Vera V.
    [J]. 2018 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2018,
  • [48] Formation of proton fluxes under the radiation belts during geomagnetic disturbances
    Gotselyuk, Yu. V.
    Kuznetsov, S. N.
    Yushkov, B. Yu.
    [J]. SOLAR SYSTEM RESEARCH, 2007, 41 (05) : 439 - 446
  • [49] Fast Heuristics for Transmission-Line Switching
    Fuller, J. David
    Ramasra, Raynier
    Cha, Amanda
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (03) : 1377 - 1386
  • [50] Bulk Power System Reliability Evaluation Considering Optimal Transmission Switching and Dynamic Line Thermal Rating
    Xiao, Ruosong
    Xiang, Yingmeng
    Wang, Lingfeng
    Xie, Kaigui
    [J]. 2016 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS (PMAPS), 2016,