Cause Analysis of Digital substation main transformer differential protection Misaction

被引:0
|
作者
Min, Wang Tian [1 ]
Bo, Gao [1 ]
机构
[1] Anyang Power Supply Co, Anyang 455000, Henan, Peoples R China
关键词
main transformer; malfunction; the GPS right; out of step;
D O I
10.4028/www.scientific.net/AMM.241-244.389
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Based on the analysis of a 110kV digital substation main transformer differential protection action situation, pointing out that the malfunction cause of the trip, give out the improvement program, improve the understanding of the GPS in the digital, and recognize the the importance of intelligent substation. Provides a theoretical and application for the proper preparation of the same type of protection device, thus effectively avoid the protection device in the series malfunction again.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [41] Analysis of traction transformer differential protection misoperation and its solution
    Lin, Guo-Song
    Li, Qun-Zhan
    [J]. Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2007, 27 (05): : 122 - 125
  • [42] A Comparative Analysis of Artificial Intelligence for Power Transformer Differential Protection
    Afrasiabi, Shahabodin
    Behdani, Behzad
    Afrasiabi, Mousa
    Mohammadi, Mohammad
    Liu, Yang
    Gheisari, Mehdi
    [J]. 2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [43] Transformer Differential Protection Using Geometrical Structure Analysis of Waveforms
    Fani, B.
    Golshan, M. E. Hamedani
    Saghaian-Nejad, M.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (03) : 204 - 224
  • [44] Analysis and comparison of sensitivity of different transformer differential protection principles
    Southeast University, Nanjing 210096, China
    不详
    [J]. Dianli Xitong Zidonghue, 2006, 24 (27-32):
  • [45] Analysis on the current phase compensation methods in differential protection for transformer
    State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    不详
    [J]. Dianli Xitong Zidonghue, 2006, 18 (33-37):
  • [46] Inrush Current On Transformer Differential Protection Affect The Analysis And Discussion
    Zhang Liu
    Xu Aoran
    Liu Li
    Zhao Yi
    [J]. 2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [47] The configuration and switch-over of voltage transformer in digital substation
    Ye, Hanhan
    Xu, Ping
    Zong, Hongliang
    Wang, Shaowei
    Ye, Feng
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (24): : 93 - 95
  • [48] Typical fault analysis and revelation of a low voltage side trip of a main transformer in a 220 kV substation
    Hu, Hao
    Wei, Huayue
    Liu, Guoyu
    Zhang, Renlong
    Cai, Zhengzi
    Yang, Minghua
    Jiang, Wang
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (19): : 153 - 161
  • [49] Applying electronic current transformer to transformer differential protection
    College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 2007, 4 (47-53):
  • [50] Study on a New Transformer Main Protection Scheme
    Wang, Xue
    Wang, Zengping
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12