Colorectal polyps:: Detection with multi-slice CT colonography

被引:31
|
作者
Wessling, J
Fischbach, R
Domagk, D
Lügering, N
Neumann, E
Heindel, W
机构
[1] Univ Munich, Dept Clin Radiol, D-48129 Munster, Germany
[2] Univ Munich, Dept Gastroenterol, D-48129 Munster, Germany
关键词
polyps; computertopographie; colography; multislier spiral CT;
D O I
10.1055/s-2001-18894
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the performance of virtual and conventional colonoscopy for the detection of colorectal polyps using a multislice spiral CT scanner (MSCT). Materials and Methods: 48 patients (20 women, 28 men, mean age 61.5 years) with clinical indication for conventional colonoscopy were prospectively studied using a MSCT (Somatom Volume Zoom, Siemens, Forchheim). Examination was performed after standard oral preparation for colonoscopy and colonic distension with room air and I. v. butylscopolamin. Images were obtained in prone and supine position using a detector configuration of 4 x 1 mm, a table feed of 5 mm/rotation at 140 mAs and 120 kV. Slice thickness and reconstruction increment were 3 and 1.5 mm, respectively. CT data were assessed by two blinded radiologists on a Vitrea workstation (Vital Images, USA) using a software with multiplanar and volume-rendering capabilities. Results: 33 patients had normal findings on conventional colonoscopy. In 15 patients a total of 30 polyps and one carcinoma with stenosis were identified. MSCT-colonography identified the carcinoma and 23 polyps (77%). 3 of 3 polyps were 10 mm or more (100%), 6 of 7 were 5.1 to 9.9 mm (86%) and 14 of 20 were 5 mm or smaller (70%). There were 13 false positive findings for polyps (10 lesions < 6mm in 5 patients) and no false positive finding of carcinoma. Conclusions: MSCT colonography allows accurate detection of polyps larger than 10 mm. Compared to published results of single-slice CT, multislice CT colonography increases the rate of detection of small colorectal polyps in particular. However, false positive results still remain a problem.
引用
收藏
页码:1069 / 1071
页数:3
相关论文
共 50 条
  • [41] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    Welch, TJ
    RADIOLOGY, 1999, 210 (02) : 586 - 586
  • [42] Technical advances in multi-slice spiral CT
    Fuchs, T
    Kachelriess, M
    Kalender, WA
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 69 - 73
  • [43] Radiation exposure in cardiac multi-slice CT
    Cohnen, MG
    Poll, LW
    Grust, A
    Puettmann, C
    Ewen, K
    Moedder, U
    RADIOLOGY, 2001, 221 : 365 - 365
  • [44] Reduction of scattering artifact in multi-slice CT
    Sabo-Napadensky, I
    Amir, O
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 983 - 991
  • [45] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    MEDICAL PHYSICS, 1999, 26 (11) : 2223 - 2230
  • [46] Scatter correction for multi-slice CT system
    Wang, Yang
    Stierstorfer, Karl
    Petersilka, Martin
    Grasruck, Michael
    Tian, Yi
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [47] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [48] Biliary malignancies: multi-slice CT or MRI?
    Wolfgang Schima
    Cancer Imaging, 2003, 3 (2) : 75 - 78
  • [49] Multi-slice CT contrast enhancement regimens
    Dawson, P
    CLINICAL RADIOLOGY, 2004, 59 (12) : 1051 - 1060
  • [50] Automated detection of lung nodules from multi-slice CT image data
    Sivaramakrishna, R
    Birbeck, S
    Higgs, BE
    Parisky, YR
    Boswell, WD
    Cothren, RM
    RADIOLOGY, 2002, 225 : 184 - 185